What Size Generator Do I Need?

Kitchen
Heating and cooling
Water and laundry
Lights and electronics
bulbs at 12 watts each

Count the LED bulbs you want on during an outage. Each bulb uses about 12 watts, the midpoint of Champion's published 8 to 15 watt range per LED bulb. For old incandescent bulbs, use the custom item rows below with the wattage printed on the bulb.

Custom items (optional)

Use these rows for anything not on the checklist, or to enter your own appliance's exact figures from its label. Find running watts on the label, or multiply volts by amps. Leave starting watts blank for items without a motor, such as heaters and lights. Starting watts must be at least the running watts.

Check a generator you already own or are considering (optional)

Enter both ratings from the generator's spec sheet. Running watts is the continuous rating, sometimes called rated watts. Starting watts is the surge rating, sometimes called peak or maximum watts. The generator's name usually carries the starting figure, not the running one.

Estimated recommended size

This tool provides estimates for general guidance only. Wattage figures are midpoints of published manufacturer ranges and vary by appliance, so the recommended size is a planning estimate. Always check the manufacturer's specifications before buying.
Quick answer: Most homes need a 5,000 to 12,500 watt generator for essential appliances, per Champion Power Equipment. Add up the running watts of everything you want to run at the same time, add the starting surge of the single largest motor, and pick the smallest generator whose running rating and starting rating both cover your totals. A refrigerator, a freezer, a furnace fan, a sump pump, six lights, a TV, and a microwave need 3,262 running watts and 4,062 starting watts, which lands in the 3,650 running watt class.

Last reviewed: 19 November 2026. Reviewed every 180 days; next review due 18 May 2027.

How to use the Home Generator Size Calculator

A generator that is too small stalls the moment a pump or an air conditioner starts. A generator that is too big wastes money on fuel, noise, and a machine you never load properly. The right size comes from a simple worksheet that every major generator maker publishes: add up the running watts of everything you want to power at the same time, then add the starting surge of the single largest motor. This calculator does that worksheet for you, with wattage figures taken from the manufacturers' own published tables. It takes less than a minute.

  1. Tick the appliances you want to run at the same time. Work through the four groups: kitchen, heating and cooling, water and laundry, and lights and electronics. Tick only what will actually be running together during an outage. A microwave you use for two minutes does not need to sit in the list with everything else if you are willing to switch it off while the well pump runs, and the calculator's power-management note below explains why that matters.
  2. Count your LED lights. Enter the number of LED bulbs you want on. Each bulb counts as 12 watts, the midpoint of Champion's published 8 to 15 watt range per LED bulb. If you still have incandescent bulbs, use a custom item row with the wattage printed on the bulb, usually 60 watts each.
  3. Add custom items for anything missing. Use the three custom rows for appliances that are not on the checklist, a second freezer, a garage door opener, an aquarium heater, or to enter your own appliance's exact figures from its label. Running watts come from the label, or from volts times amps. Leave starting watts blank for anything without a motor, such as a heater or a light. Starting watts must be at least the running watts.
  4. Check a generator you already own, if you have one in mind (optional). Enter its running watts and its starting watts from the spec sheet. Running watts is the continuous rating, sometimes called rated watts. Starting watts is the surge rating, sometimes called peak or maximum watts. The generator's name usually carries the starting figure, not the running one: a generator sold as a 10,000-watt unit, the Generac GP8000E, makes 8,000 running watts.
  5. Read your result. You get your total running watts, your total starting watts, the appliance with the largest starting surge, the smallest common generator size that covers both numbers, how hard that unit would be loaded, and plain-language guidance on transfer switches, 240-volt loads, fuel, and carbon monoxide safety.

This calculator is one of the free tools on Tools Elite. Every figure on this page comes from a published source listed at the bottom, and the calculator shows its work: the running total, the starting total, and the largest surge are all in the result. Generator sizing is an estimate, not a guarantee for a particular appliance, so treat the recommendation as a starting point and check the manufacturer's specifications before you buy. If your only loads are phones, a laptop, and a lamp, you may not need a generator at all: our Power Bank Capacity Planner sizes a power bank for small devices through a short outage.

How it works

The calculator follows the published worksheet method that Generac, Champion, Lowe's, and Honda all teach, in four steps: list the loads, add the running watts, find the largest starting surge, and match both numbers to the smallest common generator size.

Step 1: list the loads. Every appliance on the checklist carries a running-watts figure and, for motor-driven appliances, a starting-watts figure. The running figures are midpoints of Champion Power Equipment's published ranges where Champion gives a range, and Generac's published single values where Champion has no row. The full table, with every source figure, is below in the appliance wattages section.

Step 2: add the running watts. Total running watts is the sum of the running watts of everything selected. This is the continuous power your generator must supply for as long as the outage lasts, and it is the number the generator's running-watts rating must cover. A refrigerator at 275 watts, a furnace fan at 550 watts, six LED bulbs at 72 watts, a TV at 240 watts, and a sump pump at 925 watts come to 2,062 running watts.

Step 3: add the largest starting surge only. Motor-driven appliances need a short burst of extra power to start, lasting a fraction of a second to a few seconds. Generac's worksheet puts starting watts at typically twice the running watts, and Champion says starting watts are typically 1 to 2 times the running wattage. The worksheet adds only the single largest surge, because motors start one at a time, not all at once. The surge for one appliance is its total starting watts minus its own running watts, which are already counted in the running total. So total starting watts equals the largest starter's total starting watts plus the running watts of everything else. In the example above, the sump pump starts at 1,725 watts against 925 running watts, a surge of 800 watts, so the total starting watts are 2,062 plus 800, which is 2,862.

Step 4: match both numbers to the smallest common size. A generator lists two ratings, and your load must fit under both: total running watts under the running rating, total starting watts under the starting rating. The calculator checks a ladder of real common sizes, from the 1,800 running watt Honda EU2200i inverter up through the 10,500 running watt DuroMax XP13000EH portable, then the Generac Guardian standby sizes from 10 to 26 kW. It recommends the smallest rung that covers both numbers, checking portables before standby units, so a portable is recommended whenever one covers the load. In the example, 2,062 running watts and 2,862 starting watts land on the 2,800 running watt, 3,000 starting watt class, and the load is 74 percent of that unit's running rating.

Worked example. Take a home that wants to run a refrigerator, a freezer, a furnace fan, a 1/2 HP sump pump, six LED bulbs, a TV, and a microwave during an outage. Running watts: refrigerator 275, freezer 300, furnace fan 550, sump pump 925, lights 72, TV 240, microwave 900. The total is 3,262 running watts. The starting figures are refrigerator 1,000, freezer 750, furnace fan 1,200, sump pump 1,725. The largest is the sump pump at 1,725, and its surge is 1,725 minus 925, which is 800 watts. Total starting watts are 3,262 plus 800, which is 4,062. The 2,800 running watt rung fails on running watts, and the next rung, 3,650 running watts and 4,550 starting watts, covers both numbers, so that is the recommendation, loaded at 89 percent of its running rating. The load is above 80 percent, so the calculator flags it and suggests considering the next size up if you expect to add loads.

Honda's own worked example shows the same method with power management. Honda's sizing page lists a refrigerator at 200 running and 1,600 starting watts, a 1/4 HP furnace fan at 600 and 1,600, five lights at 300, a TV at 300, and a microwave at 1,500. Added naively, that is 2,900 running watts and 5,300 starting watts. But Honda splits the list into a continuous need of 1,400 watts, the fridge, furnace, lights, and TV running, and an occasional need whose largest single item is 1,600 watts, the fridge or the furnace starting. The two together are 3,000 watts, so a 3,000-watt generator runs the whole list, provided the two big motors start at different times and the microwave runs on its own. That is the whole idea of the worksheet: size for what runs together plus one surge at a time, not for every surge at once.

One convention warning. The makers do not all use the same starting-watts convention, and the difference is a real trap. Generac's worksheet uses additional starting watts, the extra above running watts. Champion's wattage chart lists total watts while starting. Champion's own sizing guide then says to add the highest starting watts to the total running watts, which double-counts the largest appliance's running watts if you use the chart's total figures. This calculator uses the total-starting convention throughout and adds only the extra surge, the largest starter's total starting watts plus the running watts of everything else, which is the physically correct total. The difference is exactly that appliance's running watts: for a refrigerator, 275 watts. The disagreement section below sets out every place the published tables differ.

What your result means

The two totals are two separate tests. Your generator's running-watts rating must be at least your total running watts, and its starting-watts rating must be at least your total starting watts. Either test can be the binding one. A list of heaters and lights has no surge at all, so the running total decides. A list with a well pump or a central air conditioner is usually decided by the starting total, because the surge is thousands of watts. The calculator shows both totals and names the appliance whose surge sets the starting figure, so you can see which test binds.

The recommended size is the smallest common rung that passes both tests. It is not the exact total, and the gap between your total and the rung is your headroom. A load of 4,762 running watts and 6,262 starting watts, for example, fails the 5,000 running watt rung by 12 starting watts, because that rung's starting rating is 6,250, and steps up to the 6,500 running watt class. That is the worksheet working as intended: a generator that cannot start your largest motor is the wrong generator, however close it looks.

The load percentage tells you how hard the unit works. Your running watts divided by the recommended unit's running rating, as a percentage, shows how much of the machine you are using. Champion advises choosing a generator that exceeds your calculated wattage by a safe margin, and many sizing guides use about 80 percent as the line for sustained running. The calculator flags any result above 80 percent and suggests considering the next size up if you expect to add loads. A unit running at 95 percent of its rating will work, but it runs hotter, louder, and with no room for the next appliance you plug in.

Portable or standby is decided by the size of the load. Up to 10,500 running watts, a portable generator covers the load, and the calculator recommends the smallest portable that fits. Above that, the recommendation becomes a home standby unit, permanently installed, running on natural gas or propane, and switching on automatically within seconds of an outage. Standby units are sold by their continuous kilowatt rating, 10, 14, 18, 22, 24, and 26 kW in Generac's Guardian line, with no separate starting-watts figure, so the calculator requires the standby's rated watts to cover your total starting watts. That is the conservative reading: a dealer sizes from the unit's motor-starting rating and may fit a smaller unit with load management, which sheds big loads in sequence rather than starting them together.

Inverter or open-frame is a second choice inside the portable class. Generac's worksheet draws the line plainly: inverters are compact, quiet, and produce clean power suited to sensitive electronics, while conventional open-frame generators deliver more power for the money and come in a much greater range of wattages. If your list is mostly electronics, lights, and a refrigerator, an inverter in the 1,800 to 2,800 running watt class is the natural fit. If your list includes a well pump, a sump pump, or central air, you are in open-frame territory, and the clean-power question is answered by the generator's voltage regulation rather than by an inverter.

The transfer-switch note is not optional. If any of your loads are wired into your home's electrical panel, a furnace fan, a pump, central air, a water heater, a dryer, the calculator says so. A portable generator powers those loads only through a manual transfer switch installed by a licensed electrician, which routes generator power to your chosen circuits and prevents back-feeding electricity into utility lines, which can kill utility workers. Lowe's puts it bluntly: do not plug a generator into a standard wall outlet. Champion says the same, and adds that the switch must be installed by a licensed electrician.

Fuel changes the answer. Champion states that propane typically delivers about 10 percent less wattage than gasoline, and natural gas about 10 to 15 percent less. The DuroMax XP13000EH shows it in its own spec sheet: 10,500 running watts on gasoline, 10,000 on propane. If you plan to run on propane or natural gas, size up one rung, or check the fuel-specific ratings on the spec sheet before you buy. The same applies to standby units, whose ratings are quoted on propane and run lower on natural gas.

Generator sizes explained

The table below is the ladder this calculator uses, with the real model each rung is anchored to and what each size typically runs. Every figure is the gasoline rating from the maker's own spec sheet or manual. Champion's own size bands sit behind the groupings: 1,000 to 3,000 watts for lights, chargers, and small appliances; 3,000 to 7,000 watts for home essentials including a refrigerator, freezer, window AC, and TV; 7,000 to 12,500 watts for central AC, an electric water heater, a well pump, and a sump pump; 12,500 to 22,000 watts for whole-home portable backup. Lowe's bands are close but not identical: 500 to 3,000 watts for recreation and small appliances, 3,100 to 6,000 for heating, cooling, and mid-size appliances, 6,100 to 10,000 for emergency power and large appliances, and 10,100 watts and above for whole-home power.

Size classRunning wattsStarting wattsTypical loads
Compact inverter1,8002,200Fridge, lights, chargers, TV
Mid-size inverter2,8003,000Fridge, furnace fan, lights, TV, microwave on its own
Mid-size portable3,6504,550Essentials plus a sump pump or window AC
5,000-watt portable5,0006,250Fridge, freezer, furnace fan, sump pump, microwave
6,500-watt portable6,5008,125Above plus a well pump or 3-ton central AC
7,500-watt portable7,5009,375Well pump, sump pump, furnace, fridge, freezer, microwave together
8,000-watt portable8,00010,000Central AC, well pump, fridge, sump pump, lights
10,500-watt portable10,50013,000Near whole-home portable backup
10 kW standby10,00010,000 ratedEssential circuits in a smaller home
14 kW standby14,00014,000 ratedEssentials plus more circuits, small window AC
18 kW standby18,00018,000 ratedBroad coverage with load management
22 kW standby22,00022,000 ratedNear whole-home for most houses
24 kW standby24,00024,000 ratedWhole-home leaning, heavier simultaneous loads
26 kW standby26,00026,000 ratedMaximum air-cooled standby coverage

Champion's rule of thumb for a 2,000 square foot house is 5,000 to 7,500 watts for essentials such as the refrigerator, lights, outlets, and a window AC, and 10,000 watts or more if you want to run central air conditioning. That is a useful sanity check on your own list, but it is not a substitute for it: two houses of the same size can need very different generators, depending on whether they have a well pump, electric heat, or a second refrigerator.

Appliance wattages the calculator uses

Every figure below is the value this calculator uses, with the published source beside it. Where Champion gives a range, the tool uses the midpoint, rounded to the nearest 25 watts where the midpoint is not already a round number. Where Champion has no row, the tool uses Generac's published single value. Where the makers disagree, the disagreement section below sets out the spread. Your own appliance's label always wins over any chart: if the label gives volts and amps, multiply them to get running watts.

ApplianceRunning wattsStarting wattsPublished source
Refrigerator2751,000Champion 150-400 / 800-1,200
Freezer (chest or upright)300750Champion 100-500 / 500-1,000
Microwave oven900NoneChampion 600-1,200
Coffee maker1,200NoneGenerac 1,200
Dishwasher1,800NoneChampion 1,200-2,400
Electric range (one burner)1,800NoneChampion 1,200-2,400
Toaster1,200NoneGenerac 1,200
Slow cooker250NoneGenerac 250
Window AC (5,000 BTU)5251,050Champion 450-600 / 900-1,200
Window AC (10,000 BTU)1,0502,100Champion 900-1,200 / 1,800-2,400
Central AC (2 ton)2,2504,000Champion 2,000-2,500 / 3,500-4,500
Central AC (3 ton)3,2505,500Champion 3,000-3,500 / 5,000-6,000
Central AC (4 ton)4,5007,250Champion 4,000-5,000 / 6,500-8,000
Furnace fan (1/2 HP)5501,200Champion 300-800 / 800-1,600
Space heater1,125NoneChampion 750-1,500
Ceiling fan45NoneChampion 15-75
Window fan125NoneChampion 50-200
Sump pump (1/3 HP)6501,300Champion 500-800 / 1,000-1,600
Sump pump (1/2 HP)9251,725Champion 800-1,050 / 1,300-2,150
Well pump (1/2 HP)8751,750Champion 750-1,000 / 1,500-2,000
Well pump (1 HP)1,5003,000Champion 1,000-2,000 / 2,000-4,000
Washing machine7501,650Champion 500-1,000 / 1,000-2,300
Electric clothes dryer5,000NoneChampion 4,000-6,000
Electric water heater3,750NoneChampion 3,000-4,500
LED light (per bulb)12NoneChampion 8-15
TV (32 to 55 inch)240NoneChampion 80-400
Desktop computer400NoneGenerac 400
Laptop computer75NoneGenerac 75
Phone charger10NoneGenerac 10
Wi-Fi router and modem15NoneChampion 10-20
CPAP machine (heated humidifier)90NoneChampion 60-120
Hair dryer1,500NoneGenerac 1,500

Two rows deserve a note. The CPAP figure is for a machine with a heated humidifier, 60 to 120 watts on Champion's chart; without heat, Champion lists 30 to 60 watts, so a CPAP without its humidifier uses about half the figure in the table. The dishwasher figure assumes the hot-dry cycle, which is what Champion's 1,200 to 2,400 watt range covers; Honda's table lists a cool-dry dishwasher at 216 running watts, a much lower figure for a much gentler cycle.

Where the published tables disagree

The makers' wattage tables do not agree with each other, and the gaps are large enough to change a recommendation. This section sets out the disagreements plainly, with the figures each maker publishes, so you can judge the tool's choices. Where tables disagree, the tool uses the midpoint of Champion's range, because Champion's chart is the most detailed manufacturer table, giving both running and starting watts for every appliance. The custom item rows exist so you can replace any figure with your own appliance's label.

Refrigerator. Champion lists 150 to 400 running watts and 800 to 1,200 starting watts. Honda's estimation guide lists an Energy Star refrigerator or freezer at 132 to 192 running watts and 1,200 starting watts, while Honda's own worked example uses 200 running and 1,600 starting watts. Generac's worksheet lists 700 running watts for a refrigerator and freezer, with starting watts typically twice running watts. The spread is 132 to 700 running watts and 800 to 1,600 starting watts, a fivefold range on the running figure. The tool uses 275 running and 1,000 starting watts, the Champion midpoints. A modern Energy Star refrigerator is near the bottom of the range; an older side-by-side is near the top.

Sump pump. Champion lists a 1/2 HP sump pump at 800 to 1,050 running watts and 1,300 to 2,150 starting watts, and Honda lists the same pump at 1,050 running and 2,150 starting watts, exactly Champion's top ends. Generac's worksheet lists a sump pump at 2,100 running watts with no horsepower stated, roughly double the other two. The tool uses 925 running and 1,725 starting watts, the Champion midpoints. If your pump is a large or high-head unit, use its label.

Window air conditioner. Champion lists a 10,000 BTU window unit at 900 to 1,200 running watts and 1,800 to 2,400 starting watts. Honda lists the same size at 1,500 running and 2,200 starting watts. Generac's worksheet lists a 12,000 BTU window unit at 3,250 running watts, roughly double to triple the other two figures. The tool uses 1,050 running and 2,100 starting watts, the Champion midpoints.

Furnace fan. Champion lists a 1/2 HP furnace fan at 300 to 800 running watts and 800 to 1,600 starting watts. Honda lists the same fan at 875 running and 2,350 starting watts, with the starting figure above the top of Champion's range. Honda's table also gives smaller fans: 1/3 HP at 700 running and 1,400 starting, 1/4 HP at 600 and 1,000. The tool uses 550 running and 1,200 starting watts, the Champion midpoints. If you know your fan's horsepower, Honda's per-horsepower table is the more precise source, and the custom rows take its figures directly.

Microwave, dishwasher, and dryer. Champion lists a microwave at 600 to 1,200 watts; Honda lists 1,000 watts for a 650-watt microwave, 1,300 for an 800-watt model, and 1,500 for a 1,000-watt model; Generac lists 1,500. A microwave's cooking watts are not its draw: the draw is higher, which is why the figures differ. The dishwasher gap is a cycle gap: Champion's 1,200 to 2,400 watts covers the hot-dry cycle, while Honda's cool-dry figure is 216 running watts. The dryer gap is small: Champion 4,000 to 6,000 watts, Honda 5,400 running and 6,750 starting.

Electronics. Generac lists a desktop computer at 400 watts and a laptop at 75 watts; Honda lists a desktop at 600 to 800 watts and a laptop at 200 to 250 watts. Generac lists an LED or LCD TV at 120 watts; Champion lists a 32 to 55 inch TV at 80 to 400 watts; Honda lists a 46-inch flat screen at 190 watts. The tool uses Generac's 400 and 75 for the computers, where Champion has no rows, and Champion's 240 midpoint for the TV.

Central air conditioning. Champion lists a 3-ton unit at 3,000 to 3,500 running watts and 5,000 to 6,000 starting watts, and the tool uses the midpoints, 3,250 and 5,500. One utility guide, DTE Energy's, as reported by preparedstates.com, puts a 3-ton unit far higher, at 6,000 running watts and about 18,000 watts to start, apparently built on locked-rotor amps for older units. If your air conditioner is old or its nameplate shows a high locked-rotor figure, the conservative move is to size from that nameplate, or to ask an electrician, rather than from any chart.

Generator ratings themselves disagree between sources. DuroMax's own product page lists the XP13000EH at 10,000 running watts and 12,500 peak watts on propane, while its owner's manual lists 9,975 running and 12,350 peak watts on propane. The gasoline figures agree at 10,500 running and 13,000 peak watts. The Champion 201504 is 3,650 running and 4,550 starting watts on gasoline per Champion's own sell sheet, although some roundups quote 4,650 starting watts; the 4,650 figure belongs to a different Champion model, the 201120 inverter. These are small gaps, but they are the reason the tool's size ladder is anchored to the makers' own spec sheets rather than to roundups.

Common mistakes to avoid

Shopping by the big number on the box. Generators are named for their starting watts, not their running watts. A generator sold as a 10,000-watt unit, the Generac GP8000E, makes 8,000 running watts. A generator sold as a 13,000-watt unit, the DuroMax XP13000EH, makes 10,500 running watts. Size on the running figure, and check the starting figure separately.

Forgetting starting watts entirely. A list sized on running watts alone will hold your lights beautifully and stall the moment the well pump or the refrigerator compressor kicks in. Every motor on the list needs its surge counted, and the worksheet counts the largest one.

Adding every motor's surge. The opposite error is just as common: adding the starting watts of every motor together. Motors start one at a time, on separate thermostats and pressure switches, so the worksheet adds only the largest single surge. Adding them all buys a generator one or two sizes too big.

Counting the largest motor twice. If you use a chart whose starting figures are total watts while starting, and then add the full starting figure to a running total that already includes that appliance, you count its running watts twice. The correct addition is the extra surge only: starting watts minus running watts for that one appliance.

Sizing by square footage. Floor area does not determine generator size. A 2,000 square foot house with gas heat and city water needs far less than the same house with a well pump, electric heat, and an electric water heater. Champion's 5,000 to 7,500 watt figure for a 2,000 square foot home is an essentials estimate, not a sizing rule. The load list decides.

Forgetting the fuel derating. A dual-fuel generator makes about 10 percent less power on propane than on gasoline, and a tri-fuel unit makes 10 to 15 percent less on natural gas. A load that fits a 5,000 running watt unit on gasoline may not fit the same unit on propane, where it makes 4,500 running watts.

Skipping the transfer switch. Extension cords are fine for plug-in loads. Wired-in loads need a transfer switch installed by a licensed electrician. Plugging a generator into a wall outlet back-feeds power into the grid and can kill a utility worker restoring power to your street.

Running the generator too close, or indoors. A portable generator belongs outdoors, at least 20 feet from the house, with the exhaust pointed away from doors, windows, and vents. A garage with the door open is not outdoors. Carbon monoxide is colorless and odorless, and a running generator can fill an enclosed space with deadly levels within minutes. Keep a working carbon monoxide alarm in your home, and buy a generator with an automatic carbon monoxide shutoff if you can.

Buying exactly the calculated size. The worksheet gives a minimum. Champion advises choosing a generator that exceeds your calculated wattage by a safe margin, for unexpected surges and for the loads you will add later. The calculator's load percentage shows how much margin the recommended size leaves.

Using stale wattage figures. Old worksheets list a television at 300 to 400 watts, a CRT-era figure, and a block of household lights at 600 watts, an incandescent-era figure. A modern LED TV draws 80 to 400 watts depending on size, and six LED bulbs draw 72 watts. Using the old figures oversizes the generator for no reason.

Frequently asked questions

What size generator do I need for my house?

It depends on what you want to run at the same time, not on the size of the house. Champion says most homes need a 5,000 to 12,500 watt generator to keep essential appliances running during an outage, and puts a 2,000 square foot home at 5,000 to 7,500 watts for essentials, or 10,000 watts and more with central air conditioning. A list of a refrigerator, a freezer, a furnace fan, lights, and chargers lands in the 1,800 to 3,650 running watt class. Adding a well pump or a sump pump moves it to the 5,000 to 6,500 class. Adding central air conditioning moves it to 6,500 watts and up, or to a standby unit. Tick your own list in the calculator above for the answer that fits your home.

What size generator do I need to run a refrigerator?

A modern refrigerator runs at 150 to 400 watts and starts at 800 to 1,200 watts, per Champion's wattage chart. Champion's own answer to this question is yes, a 3,500-watt generator runs a refrigerator, with wattage left over for lights and small devices. On this calculator's figures, a refrigerator alone needs 275 running watts and 1,000 starting watts, which fits the smallest portable class, a 1,800 running watt inverter, with room for lights and chargers. An older refrigerator draws more, so check the label: Honda's table puts an Energy Star refrigerator at 132 to 192 running watts and 1,200 starting watts, while Generac's worksheet uses 700 running watts as a cautious planning figure.

How many watts does it take to run a whole house?

There is no single number, because a whole house is a list, not a size. Lowe's puts whole-home power at 10,100 watts and above, and Champion puts whole-home portable backup at 12,500 to 22,000 watts, with standby units from 8,500 to 26,000 watts. A home running central air, an electric water heater, an electric dryer, a well pump, and a full kitchen at once can pass 20,000 running watts, which is standby territory. The same home running only its essentials, fridge, freezer, furnace fan, lights, and a pump, needs 3,000 to 7,000 watts. The honest answer starts with the list, which is what the calculator above builds.

What is the difference between running watts and starting watts?

Running watts, also called rated watts, are the continuous power an appliance needs while it works. Starting watts, also called surge or peak watts, are the short burst a motor needs to get moving, lasting a fraction of a second to a few seconds. Generac's worksheet puts starting watts at typically twice the running watts, and Champion says starting watts are typically 1 to 2 times the running wattage. Appliances without a motor, such as microwaves, coffee makers, lights, and space heaters, have no starting surge and are sized on running watts only. A generator must cover both numbers: its running rating must meet your total running watts, and its starting rating must meet your total starting watts.

Can a portable generator run my central air conditioner?

Yes, if it is big enough, and the starting watts are usually the binding number. Champion lists a 3-ton central air conditioner at 3,000 to 3,500 running watts and 5,000 to 6,000 starting watts. With a refrigerator, a furnace fan, lights, and a TV alongside it, the totals come to about 4,400 running watts and 6,650 starting watts, which needs a 6,500 running watt portable. A 2-ton unit needs less, and a 4-ton unit needs more: 4,500 running and 7,250 starting watts on this calculator's figures. Champion advises planning for 10,000 watts or more if you want to run central air in a 2,000 square foot home. Older air conditioners can draw far more at startup, so check the nameplate's locked-rotor figure, or ask an electrician, before sizing a portable for central air.

Do I need a transfer switch for a portable generator?

Yes, if you are connecting the generator to your home's electrical system rather than running extension cords to individual appliances. Champion says a manual transfer switch, installed by a licensed electrician, safely routes generator power to your chosen circuits and prevents back-feeding electricity into utility lines, which can be dangerous for utility workers. Lowe's says the same: do not plug a generator into a standard electrical wall outlet, and hire an electrician to install a transfer switch. Any load wired into your panel, a furnace fan, a pump, central air, a water heater, a dryer, needs the switch. Plug-in loads such as a refrigerator, a TV, or a phone charger can run on heavy-duty extension cords.

How far from the house should a generator sit?

At least 20 feet from your home, outdoors, with the exhaust pointed away from doors, windows, and vents. That is the rule Lowe's states in its sizing guide, and the CDC and the Consumer Product Safety Commission give the same 20-foot figure. Never run a generator indoors, and never in a garage, basement, shed, or enclosed patio, even with the doors open: carbon monoxide is colorless and odorless, and deadly levels can build up within minutes. Keep a working carbon monoxide alarm in your home, and look for a generator with an automatic carbon monoxide shutoff, which Champion calls CO Shield and Generac calls COsense.