Hydroponic Nutrient Calculator
Your nutrient dose
How the answer was worked out
Keep growing: our Houseplant Fertilizer Dilution Calculator works out the dilution for potted plants, our Garden Watering Calculator plans how much water a bed needs, and our Soil Test Interpreter reads a soil test report and explains what to add.
Last reviewed: 21 November 2026. Reviewed every 180 days; next review due 20 May 2027.
How to use the Hydroponic Nutrient Calculator
Hydroponic growing removes the soil, so the nutrient solution is the only food the plants get. The strength of that solution is measured as electrical conductivity (EC), and every crop and growth stage has a target EC. This calculator turns that target into a dose you can measure: how many milliliters of concentrate to add per gallon of water, and how much to add to the whole reservoir.
Start with the reservoir size. Enter the volume of water in the reservoir, in gallons or liters. A five-gallon bucket system, a 20-gallon reservoir under a table, and a 100-gallon commercial tank all work the same way: the dose per gallon stays the same, and the total scales with the volume. If you are not sure of the volume, measure the reservoir with a gallon jug or a liter measure once and write the number on the tank. Guessing the volume is the most common reason a first mix comes out wrong.
Then choose the crop and the growth stage. The calculator holds EC target ranges for four crop groups: lettuce and leafy greens, herbs, tomatoes and fruiting crops, and a general group for mixed crops. Each group has a range for seedlings, for the vegetative stage, and for flowering and fruiting. The ranges come from published extension and university tables, which are listed in the sources section below. Seedlings always take the weakest solution, plants in full vegetative growth take a medium solution, and fruiting plants take the strongest.
You can set the target three ways. The default is by crop stage: the calculator takes the midpoint of the published range for the crop and stage you chose. That is the right choice for most growers, and it is the choice to use if you have no other guidance. The second way is to enter a target EC directly, in millisiemens per centimeter (mS/cm). Use this when your product label, a feed chart, or a grower you trust gives you an EC number. The third way is to enter a target in parts per million (ppm), and to pick the scale your meter uses: the 500 scale or the 700 scale. The two scales give different ppm numbers for the same solution, so the scale matters. The calculator converts your ppm target to EC before doing any dose math, because EC is the same on every meter.
Next, enter the EC of your source water if you know it. Tap water, well water, and rainwater all carry some dissolved salts, and those salts add to the EC of the finished solution. The meter cannot tell nutrient salts from the salts already in the water, so a reservoir filled with hard tap water needs less concentrate than one filled with reverse osmosis water. If you have not measured your source water, leave the field blank and the calculator assumes zero. Measuring it once is worth the effort: it is the single most useful number for a grower on hard water.
Then choose the nutrient system. A single concentrate is one bottle that holds everything; the calculator gives one dose in milliliters per gallon. A three-part system (Micro, Gro, and Bloom) is three bottles that are mixed in a ratio; the calculator splits the total dose into the three parts, using the reference recipe's ratio for the growth stage. The split is shown per gallon and as totals for the whole reservoir.
Finally, the label figures. Every nutrient product has its own strength, so the calculator needs to know how strong yours is. Enter the dose the label gives, in milliliters per gallon, and the EC that dose produces. If you leave both blank, the calculator uses the reference recipe for the stage: the General Hydroponics Flora Series Light Feed values for that stage. That reference is a published feed chart, not a recommendation to buy a particular product. Replace the figures with your own product's label whenever you know them. A label that says 10 mL per gallon produces 1.0 mS/cm is a very different product from one that says 15.8 mL per gallon produces 1.55 mS/cm, and the dose changes accordingly.
When you have entered everything, the calculator shows the dose per gallon, the total for the reservoir, the target EC and ppm, the nutrient EC you are adding, the dose per liter, the pH target for the crop, and a rough equivalent in teaspoons and fluid ounces. It also shows the working step by step, so you can check the arithmetic, and any warnings that apply: a target outside the published range for the crop and stage, hard source water, a very high EC, or a dose so large or so small that it deserves a second look.
How the calculator works
The calculator does one piece of arithmetic, and it shows the working so you can check it. First it settles the target EC. In stage mode that is the midpoint of the published range for the crop and stage. In EC mode it is the number you entered. In ppm mode it is your ppm target divided by the scale you picked: 800 ppm on the 700 scale is 1.14 mS/cm, and the same 800 ppm on the 500 scale would be 1.60 mS/cm. The conversion is exact, and the target EC is rounded to two decimal places.
Then it subtracts the source-water EC from the target. The difference is the nutrient EC: the strength the concentrate has to supply. If your tap water already reads 0.4 mS/cm and the target is 1.25 mS/cm, the nutrient only has to add 0.85 mS/cm. If the source water reads at or above the target, the calculator tells you so and gives no dose: there is nothing to add, and the right move is lower-EC water or a higher target. That is not an error in the calculator. It is the correct answer for hard water.
Then it scales the label dose. Nutrient EC rises roughly in proportion to the dose in the working range, so the dose you need is the label dose times the ratio of the nutrient EC you need to the EC the label dose gives. A label dose of 15.8 mL per gallon that produces 1.55 mS/cm, used to supply 0.85 mS/cm, gives 15.8 times 0.85 divided by 1.55, which is 8.7 mL per gallon. The calculator prints the ratio in the steps so you can verify it with exact arithmetic.
The total for the reservoir is the per-gallon dose times the number of gallons. Liters are converted to gallons first at 3.78541 liters per gallon, so a 20-liter reservoir is 5.28 gallons. The per-liter dose is the per-gallon dose divided by 3.78541. Teaspoons are computed at 5 mL per teaspoon and fluid ounces at 29.5735 mL per fluid ounce, and both are shown as rough equivalents only: measure concentrate with a measuring syringe or a graduated cylinder, not a kitchen spoon, whenever the dose is small.
In three-part mode the total dose is split in the reference recipe's ratio for the stage. The split is rounded to one decimal place per part, and the rounding remainder is added to the largest part so the three parts sum exactly to the per-gallon total. The reservoir totals are rounded the same way, so they sum exactly to the reservoir total. Nothing is lost to rounding, and the sums shown in the steps balance exactly.
Two things the calculator does not do are worth saying plainly. It does not measure anything. The dose it gives is a starting point, and the EC meter reading after mixing is the check that matters. Add the concentrate, stir well, let the solution settle, and read the meter. If the reading is high, add water. If it is low, add concentrate a little at a time. And it does not replace the product label. The label is written for the product in the bottle. When the label and this calculator disagree, read the label first, then check the figures you entered: a wrong label dose or label EC in the inputs is the usual cause.
EC targets by crop and growth stage
The table below gives the EC ranges the calculator uses, in millisiemens per centimeter. They are built from the published tables listed in the sources: the Oklahoma State University Extension guide, which gives EC ranges for a wide list of crops; the UF/IFAS lettuce guide, which gives 1.4 to 1.8 mS/cm as ideal for lettuce; the Cornell CEA lettuce handbook, which runs lettuce at 1.15 to 1.25 mS/cm above the source-water EC; and the University of Arizona CEAC tomato recipes, which run tomatoes from 0.5 mS/cm at propagation to 1.6 mS/cm at the balanced stage. The calculator's ranges sit inside the published ranges, with the seedling ranges at the gentle end.
| Crop | Seedling | Vegetative | Flowering and fruiting | pH target |
|---|---|---|---|---|
| Lettuce and leafy greens | 0.4 to 0.8 | 1.0 to 1.5 | 1.2 to 1.8 | 5.6 to 6.0 |
| Herbs | 0.4 to 0.8 | 1.0 to 1.6 | 1.2 to 1.8 | 5.5 to 6.0 |
| Tomatoes and fruiting crops | 0.5 to 0.9 | 1.2 to 1.8 | 1.8 to 2.6 | 5.8 to 6.5 |
| General (mixed crops) | 0.4 to 0.8 | 1.2 to 1.8 | 1.6 to 2.4 | 5.5 to 6.5 |
Read the table as a guide, not as a rule. A crop at the low end of its range grows a little more slowly and is safe from salt stress; a crop at the high end grows faster but is closer to the point where salt damages roots. The calculator's default target is the midpoint, which is a good starting point for a new crop or a new system. As you learn how a crop behaves in your system, you can move the target toward the low end or the high end by entering an EC directly.
Lettuce deserves a note. Lettuce is grown for its leaves and harvested before it flowers, so there is no separate flowering feed for lettuce in any published chart. The calculator's lettuce flowering range is the mature-plant range, and the calculator says so in the guidance when you pick it. If you are growing lettuce to harvest, the vegetative range is the one to use.
Tomatoes are the opposite: they have the widest span of any crop in the table, from 0.5 mS/cm for seedlings to 2.6 mS/cm at full fruiting, and the published ranges for tomatoes run higher still. The Oklahoma State table gives tomatoes 2.0 to 4.0 mS/cm, and the CEAC workbook discusses root-zone EC values of 4.0 to 4.5 mS/cm in the slab for steering the plant toward fruit. Those root-zone numbers are not feed numbers: the EC inside the growing medium climbs above the EC of the feed because the plant takes up water faster than salts. Do not feed tomatoes at 4.0 mS/cm because you read a slab EC of 4.0 somewhere. The calculator warns you if you enter a target above 4.0 mS/cm, because no published crop range in the Oklahoma State table tops 4.0.
Herbs are the most forgiving group in the table. Basil, sage, mint, and parsley all sit in the 1.0 to 1.6 mS/cm band in the Oklahoma State table, and they tolerate a wide range without complaint. That makes herbs a good first crop for a new grower: the target is not fussy, and a small error in either direction does little harm.
EC and ppm: the 500 scale and the 700 scale
EC is a measurement. A meter puts a small electric current through the solution and reads how easily it flows; more dissolved salts mean more current, and the reading is reported in millisiemens per centimeter. One millisiemens per centimeter is the same on every meter, in every country, for every nutrient brand. That is why extension services and university programs report their targets in EC, and why this calculator does all of its dose math in EC.
Parts per million is a conversion, not a measurement. A ppm meter is an EC meter with a multiplier built in: it measures the EC and multiplies by a fixed factor to show ppm. The trouble is that different makers use different factors. The 500 scale multiplies EC by 500, and it is based on sodium chloride. The 700 scale multiplies EC by 700, and it is based on potassium chloride. A 650 scale also exists. So a solution at 2.4 mS/cm reads 1200 ppm on a 500-scale meter, 1680 ppm on a 700-scale meter, and 1560 ppm on a 650-scale meter. Same solution, three numbers.
That is why a ppm number without its scale is meaningless, and why this calculator makes you pick the scale before it accepts a ppm target. If you do not know which scale your meter uses, check the meter's manual or the maker's website. Many meters print the scale on the body or in the settings menu. If you cannot find it, work in EC: every meter shows EC, and EC needs no scale. Bluelab, which makes meters, says the same thing in its support pages: work in EC, because the true ppm of a solution can only be found by a chemical analysis, and a ppm reading from a meter is an estimate built on a conversion factor.
| EC (mS/cm) | ppm on the 500 scale | ppm on the 700 scale |
|---|---|---|
| 0.5 | 250 | 350 |
| 1.0 | 500 | 700 |
| 1.25 | 625 | 875 |
| 1.5 | 750 | 1050 |
| 2.0 | 1000 | 1400 |
| 2.2 | 1100 | 1540 |
| 2.6 | 1300 | 1820 |
The conversion in the other direction is a division. A target of 1000 ppm on the 500 scale is 1000 divided by 500, which is 2.0 mS/cm. The same 1000 ppm on the 700 scale is 1000 divided by 700, which is 1.43 mS/cm. The difference is large: feeding at 1.43 mS/cm when you meant 2.0 mS/cm starves a fruiting crop, and feeding at 2.0 when you meant 1.43 burns a young one. When the calculator is set to ppm mode on the 700 scale, it also tells you what the solution reads on the 500 scale, so you can check the number against any chart that uses the other scale.
One more unit you may meet is CF, or conductivity factor. CF is EC times 10: a solution at 1.5 mS/cm is 15 CF. It is the same measurement in a different coat, and it is common on meters sold in Australia and New Zealand. If your meter reads CF, divide by 10 to get EC.
The reference feed chart
The calculator's default calibration comes from the General Hydroponics Flora Series 3-part feed program, as published on the maker's website and revised on 7 July 2026. The chart gives the dose of each part in milliliters per gallon, the target EC, the target ppm on the 500 scale, and the nitrogen level for each week of a 13-week program. The calculator uses the Light Feed column, which is the chart's gentlest program and the right default for home growers.
| Week | Stage | Micro | Gro | Bloom | EC (mS/cm) | ppm (500 scale) | Nitrogen (ppm) |
|---|---|---|---|---|---|---|---|
| 1 | Seedling and clone | 1.8 | 1.8 | 1.8 | 0.4 to 0.5 | 200 to 300 | 45 |
| 2 | Early growth | 3.6 | 3.4 | 2.6 | 0.9 to 1.1 | 400 to 550 | 95 |
| 3 | Early growth | 4.9 | 4.6 | 3.4 | 1.2 to 1.4 | 550 to 750 | 125 |
| 4 | Late growth | 6.0 | 5.6 | 4.2 | 1.4 to 1.7 | 700 to 900 | 150 |
| 5 to 6 | Early bloom | 7.6 | 6.6 | 8.5 | 2.0 to 2.4 | 1000 to 1200 | 180 |
| 7 to 9 | Mid bloom | 4.6 | 4.6 | 6.6 | 1.4 to 1.7 | 700 to 850 | 115 |
| 10 to 11 | Late bloom | 3.3 | 3.3 | 4.0 | 0.9 to 1.1 | 450 to 600 | 80 |
| 12 | Ripen | 2.0 | 2.0 | 3.2 | 0.6 to 0.8 | 300 to 400 | 60 |
| 13 | Flush | Water only | Water only | Water only | Water only | Water only | 0 |
Notice the shape of the program. The dose rises through the growth weeks, peaks in early bloom, then falls away through mid bloom, late bloom, and ripening to a water-only flush in the last week. The plant's appetite is not a straight line: it wants the most food when it is setting fruit, and the least when it is finishing. A grower who feeds the same dose from week 1 to week 13 overfeeds the seedling and underfeeds the fruiting plant.
The calculator maps the chart onto its three stages. Seedling uses week 1: 1.8 mL of each part per gallon, 5.4 mL in total, at a midpoint EC of 0.45 mS/cm. Vegetative uses week 4, late growth: 6.0 mL of Micro, 5.6 mL of Gro, and 4.2 mL of Bloom, 15.8 mL in total, at a midpoint EC of 1.55 mS/cm. Flowering uses week 5, early bloom: 7.6 mL of Micro, 6.6 mL of Gro, and 8.5 mL of Bloom, 22.7 mL in total, at a midpoint EC of 2.2 mS/cm. Those three rows are the reference calibration the calculator uses when you leave the label figures blank.
The chart is a reference, not a recommendation. General Hydroponics is one maker among many, and its chart is used here because the spec for this tool names manufacturer feed charts as a source and because this chart publishes its EC values openly, which makes it possible to calibrate a calculator against it. If you use another product, enter that product's label figures. The calculator's job is to scale whatever label you give it, and the reference is only a fallback for growers who do not have label figures to hand.
Feed charts change. The current page was revised on 7 July 2026, and its Light Feed values for early bloom match the Aggressive values in an older PDF version of the chart, which shows that a maker can move its numbers between editions. This page and the calculator are calibrated to the current page, and the review cycle for this tool checks the chart again. If you hold a printed chart that disagrees with the numbers here, the printed chart may be an older edition. Check the maker's website for the current version.
Tomato recipes from the University of Arizona
The University of Arizona Controlled Environment Agriculture Center (CEAC) runs one of the best-documented tomato programs in the world, and its 2026 greenhouse hydroponic tomato workshop workbook publishes the full recipes. The recipes give the concentration of every element in parts per million, the total dissolved solids, the EC of the nutrient alone, the EC with Tucson tap water added, and the pH, for four stages.
| Stage | Weeks | Nitrogen | Phosphorus | Potassium | Calcium | EC (nutrient) | EC (with tap water) | pH |
|---|---|---|---|---|---|---|---|---|
| Propagation (half strength) | 0 to 4 | 80 | 20 | 85 | 90 | 0.5 | 0.9 | 6.0 |
| Vegetative | 4 to 8 | 160 | 40 | 170 | 180 | 1.1 | 1.5 | 6.0 |
| Generative | 8 to 12 | 170 | 47 | 240 | 200 | 1.4 | 1.8 | 5.8 |
| Balanced | 12 and later | 200 | 50 | 260 | 230 | 1.6 | 2.0 | 6.0 |
Three things in that table matter for a home grower. First, the EC column is the nutrient alone, and the EC with tap water column is about 0.4 mS/cm higher. That is the base-EC effect in a real program: Tucson tap water adds roughly 0.4 mS/cm, and the CEAC recipes account for it openly. Your tap water may add more or less, which is why the calculator has a source-water field.
Second, the balance of elements changes as the plant grows. Nitrogen rises from 80 to 200 ppm, but potassium rises faster, from 85 to 260 ppm, and calcium from 90 to 230 ppm. The generative and balanced stages are potassium-heavy because fruit needs potassium. That is why three-part systems shift their ratio toward Bloom in the flowering stage: Bloom is the potassium-rich part.
Third, the EC values are modest. The balanced stage, which is the strongest recipe in the workbook, is 1.6 mS/cm of nutrient, 2.0 mS/cm with tap water. Those are working commercial numbers for greenhouse tomatoes. A home grower feeding tomatoes at 2.5 or 3.0 mS/cm is well above what a research greenhouse uses, and should have a reason for it. The calculator's tomato flowering range tops out at 2.6 mS/cm, which leaves room above the CEAC balanced recipe for growers in hot climates or with heavy-fruiting varieties, without going anywhere near the 4.0 mS/cm ceiling of the Oklahoma State table.
Lettuce: what the Cornell handbook says
The Cornell CEA lettuce handbook, written by Brechner and Both at Cornell University, is the most detailed public recipe for hydroponic lettuce. It runs a 35-day cycle: 11 days of germination, transplant on day 11, re-spacing on day 21, and harvest on day 35, producing heads of about 150 grams. Fertilizer goes in 24 hours after sowing, and the EC is held at 1200 microsiemens per centimeter, which is 1.2 mS/cm, above the source-water EC. The handbook's set-point range is 1150 to 1250 microsiemens per centimeter above the source water, and the pH is held at 5.6 to 6.0, with 5.8 as the target.
The phrase "above the source-water EC" is the important part. Cornell does not give a single EC number for lettuce. It gives a number to add to whatever the source water reads. A grower on reverse osmosis water at 0.0 mS/cm feeds at 1.2 mS/cm total. A grower on tap water at 0.4 mS/cm feeds at 1.6 mS/cm total. The nutrient EC is the same in both cases: 1.2 mS/cm. That is exactly the arithmetic this calculator does when you enter a source-water EC, and it is why the calculator shows the nutrient EC as its own line in the results.
The handbook also publishes the final fertilizer solution concentrations: nitrogen 125 ppm, phosphorus 31 ppm, potassium 215 ppm, calcium 84 ppm, magnesium 24 ppm, sulfur 35 ppm, and the trace elements iron 0.94 ppm, manganese 0.14 ppm, boron 0.16 ppm, copper 0.03 ppm, zinc 0.13 ppm, and molybdenum 0.03 ppm. Those are the numbers a complete lettuce nutrient should deliver at the target EC. A home grower does not need to mix from raw salts to hit them, but they are a useful check: if a product's label gives its guaranteed analysis, the ratios should look roughly like these.
Cornell also sets the environment around the solution. Air temperature 24 degrees Celsius by day and 19 degrees at night. Water temperature no higher than 25 degrees, cooled at 26 and heated at 24. Relative humidity 50 to 70 percent. Dissolved oxygen above 4 ppm, with visible stress at 3 ppm and crop failure below it. Light 17 moles per square meter per day. Those numbers matter because a plant that is hot, airless, or dark cannot use the nutrient you give it, however carefully you mix it. If the leaves look wrong and the EC is right, check the water temperature and the oxygen before you change the feed.
Your source water counts too
Every grower starts with water, and no water is pure. Tap water carries calcium, magnesium, sodium, chloride, sulfate, and bicarbonate, in amounts that vary from one city to another and from one well to another. Those salts raise the EC, and the meter reads them exactly as it reads nutrient salts. The Oklahoma State Extension guide gives limits for irrigation water: sodium under 50 ppm, calcium under 150 ppm, magnesium bicarbonate under 50 ppm, chloride under 140 ppm, and sulfate under 100 ppm. Water inside those limits is fine to grow with. Water far outside them is a problem that no amount of careful dosing will fix, because the salts in it are not plant food and they take up room in the EC budget that the nutrient needs.
The practical test is simple: measure the source water with the EC meter before you add anything. A reading under 0.5 mS/cm is good water for hydroponics. A reading between 0.5 and 1.0 mS/cm is workable, and the calculator's base-EC field exists for exactly this case: enter the reading, and the calculator reduces the dose so the finished solution still hits the target. A reading above 1.0 mS/cm is hard or salty water, and the calculator warns you. At that level the source water is supplying a large part of the target EC with salts the plants do not need, which leaves little room for nutrient. The usual fix is reverse osmosis water, or a blend of reverse osmosis water and tap water, which brings the base EC down to a level where the nutrient can do its job.
Rainwater is usually very low in EC, often under 0.1 mS/cm, and it is excellent for hydroponics if it is collected cleanly. Well water varies wildly: some wells are soft and clean, others are hard enough to make hydroponics difficult without treatment. If you are on a well, a water test from a local lab is money well spent. It gives you the individual salt levels, not just the total EC, and it tells you whether the problem is calcium, which plants can use, or sodium, which they cannot.
One mistake to avoid: do not try to fix hard water by feeding less nutrient and hoping for the best. A solution at the right EC that is mostly tap-water salts is underfed in the elements that matter, and the plants will show it. The EC reading looks right, but the plants are hungry. If the base EC is above 1.0 mS/cm, fix the water, not the dose. The same logic applies in soil growing, where a soil test interpreter can tell you what the soil already holds before you add fertilizer.
Mixing order for three-part nutrients
Three-part nutrients exist because some salts cannot share a bottle. Calcium and sulfate, for example, form calcium sulfate, which falls out of solution as a solid, if they are mixed at full strength. The three bottles keep the incompatible salts apart until they are diluted in the reservoir. That is why the mixing order matters, and why the chart's instruction is absolute: always add Micro to fresh water first and mix thoroughly, then add Gro second, then add Bloom third, mixing well between each addition. Never combine the concentrated parts together undiluted.
The order is Micro, Gro, Bloom. Add the Micro to the full volume of water, stir, and wait until it is fully mixed. Then add the Gro, stir again. Then add the Bloom, stir again. Then check the EC and the pH, and adjust them before feeding. Mixing in a different order, or pouring two parts into a measuring jug together to save time, risks precipitation: the salts fall out as a white cloud or a gritty deposit, and once they have precipitated they do not go back into solution. The plants lose those elements, and the EC reading becomes meaningless because part of the nutrient is sitting on the bottom of the tank as a solid.
Single concentrates do not have this problem, because the maker has already solved the compatibility question inside the bottle, usually by keeping the concentration low enough that the salts stay dissolved. That is one reason single concentrates are popular with beginners: one bottle, one dose, no order to remember. The trade is flexibility. A three-part system lets you change the ratio for the stage, pushing more Bloom at flowering or more Gro in vegetative growth, while a single concentrate gives you one ratio for the whole cycle.
Whichever system you use, mix into the full volume of water, not into a small amount that you then top up. Concentrated nutrient in a small volume of water is more likely to precipitate, and it is harder to get an even mix. Fill the reservoir, add the nutrient, stir, and then measure. If you use a pump or an air stone, let it run for a few minutes before you take the EC reading, so the solution is uniform.
Topping up and the two-week refresh
A reservoir is not a set-and-forget system. Plants take up water and nutrients at different rates, and the balance in the tank drifts from the day you mix it. In warm weather a leafy crop can drink a large part of the reservoir in a day, and the EC climbs as the water level falls, because the salts are left behind. In cool weather the plants drink less, and the EC falls as they take up nutrients faster than water. The only way to know is to measure: check the EC and the pH every day, and top up with plain water when the level falls.
When you top up, use plain water, not more nutrient solution. The plants have taken water out of the tank, and the salts are still in there, so the top-up water brings the EC back down toward the target. Adding nutrient solution as a top-up raises the EC above the target and pushes the plants toward salt stress. If the EC has fallen below the target even after topping up with water, that means the plants have eaten more nutrient than water, and a small addition of concentrate, measured with the meter, brings it back. Add a little, stir, measure, and repeat. It is easier to add more than to take it out.
Oklahoma State Extension advises replacing the nutrient solution completely every two weeks. That advice stands even when the EC looks fine, because the EC only measures the total salts, not the balance. Over two weeks the plants take up the elements they want most, and the ones they want least accumulate. Nitrogen and potassium fall first; calcium and sulfate build up. The solution can read the right EC and still be the wrong food. A full change every two weeks resets the balance. In a small system that is a bucket of water and ten minutes of work. In a large system it is worth scheduling: pick a day, drain, clean, and refill.
Between full changes, watch the pH as well as the EC. The pH drifts as the plants feed, usually upward as they take up nitrate, and the drift is fastest in a young solution and in warm weather. Check the pH after the EC is right, and adjust with a small amount of pH up or pH down solution, or with the acids and bases the handbooks name: potassium hydroxide to raise the pH, nitric acid to lower it. Adjust a little at a time. A large pH swing is harder on the plants than a pH that is slightly off target.
Worked examples
Example 1: lettuce in a five-gallon reservoir, vegetative stage. The range for lettuce at the vegetative stage is 1.0 to 1.5 mS/cm, so the target is the midpoint, 1.25 mS/cm, which is 625 ppm on the 500 scale. The source water is reverse osmosis water at 0.0 mS/cm, so the nutrient has to supply the full 1.25 mS/cm. The reference dose for the vegetative stage is 15.8 mL per gallon at 1.55 mS/cm, so the dose is 15.8 times 1.25 divided by 1.55, which is 12.7 mL per gallon. For five gallons that is 63.5 mL in total, about 12.7 teaspoons. The pH target for lettuce is 5.6 to 6.0.
Example 2: tomatoes in a 20-gallon reservoir, flowering stage, three-part system, tap water at 0.4 mS/cm. The range for tomatoes at flowering is 1.8 to 2.6 mS/cm, so the target is the midpoint, 2.2 mS/cm. The tap water supplies 0.4 mS/cm, so the nutrient has to add 1.8 mS/cm. The reference dose for the flowering stage is 22.7 mL per gallon at 2.2 mS/cm, so the dose is 22.7 times 1.8 divided by 2.2, which is 18.6 mL per gallon. Split in the reference ratio, that is 6.2 mL of Micro, 5.4 mL of Gro, and 7.0 mL of Bloom per gallon. For 20 gallons the totals are 124 mL of Micro, 108 mL of Gro, and 140 mL of Bloom, 372 mL in total. The pH target for tomatoes is 5.8 to 6.5.
Example 3: herbs in a 10-gallon reservoir, target 800 ppm on the 700 scale. The target in EC is 800 divided by 700, which is 1.14 mS/cm. The same solution reads 570 ppm on the 500 scale. The target sits inside the 1.0 to 1.6 mS/cm range for herbs at the vegetative stage. The reference dose is 15.8 mL per gallon at 1.55 mS/cm, so the dose is 15.8 times 1.14 divided by 1.55, which is 11.6 mL per gallon, and 116 mL in total for 10 gallons. The pH target for herbs is 5.5 to 6.0.
Example 4: the same lettuce reservoir as example 1, but filled with tap water at 0.4 mS/cm instead of reverse osmosis water. The target is still 1.25 mS/cm, but the tap water supplies 0.4 mS/cm, so the nutrient only has to add 0.85 mS/cm. The dose is 15.8 times 0.85 divided by 1.55, which is 8.7 mL per gallon, and 43.5 mL in total for five gallons. The tap water cut the dose by nearly a third. That is money saved and salt stress avoided, and it is the reason the calculator asks about source water.
Example 5: a label override. A grower has a single concentrate whose label says 10 mL per gallon produces 1.0 mS/cm. For the same lettuce reservoir, the dose is 10 times 1.25 divided by 1.0, which is 12.5 mL per gallon, and 62.5 mL in total. The result is close to the reference recipe's 12.7 mL per gallon, which is reassuring: two different products, calibrated honestly, give nearly the same dose for the same target. If a label override gives a wildly different dose from the reference, check the figures you entered before you trust the answer.
Common problems
The EC reading is higher than the target after mixing. The most likely cause is the source water: a base EC you did not measure, or a reservoir that was not full when you dosed. The fix is to add plain water a little at a time, stirring and measuring, until the reading comes down. Do not drain the reservoir and start again unless the reading is far above the target. A reading 0.2 or 0.3 mS/cm high is corrected with water; a reading double the target means the dose was doubled, and starting again is faster.
The EC reading is lower than the target after mixing. Either the dose was short, the reservoir is larger than you thought, or the concentrate is weaker than the label figures you entered. Add concentrate a little at a time, stirring and measuring, until the reading comes up. If you have to add far more than the calculator said, measure the reservoir volume. A "20-gallon" tank that actually holds 25 gallons is a common surprise.
The EC climbs every day without adding anything. The plants are drinking water faster than they are eating nutrient, which is normal in warm weather and under strong light. Top up with plain water to bring the EC back down. If the EC climbs even with regular top-ups, the target may be too high for the conditions, or the plants may be stressed and not feeding. Check the water temperature: above 25 degrees Celsius, roots slow down and the solution concentrates.
The EC falls every day. The plants are eating faster than they are drinking, which is normal for a fast-growing leafy crop in cool weather. Top up with a half-strength solution, or add a small amount of concentrate after topping up with water, and measure. If the EC falls fast in a young system, the plants may be telling you the target is too low.
The pH drifts up every day. This is the normal direction of drift for a nitrate-fed crop. Adjust it down a little each day, and check that the drift is slowing. A pH that climbs by 0.5 or more in a day, every day, suggests the solution is nearly exhausted or the water is very alkaline. A full reservoir change resets it.
Tipburn on lettuce: brown, dead edges on the inner leaves. Tipburn is a calcium problem, and it is usually caused by poor air movement or by an EC that is too high, both of which slow calcium transport to the growing tip. Lower the EC toward the bottom of the range, improve air circulation around the plants, and make sure the calcium in the nutrient is actually reaching the leaves. Raising the dose makes tipburn worse, not better.
White crust on the reservoir or the growing channels. That is salt buildup from evaporation and from solution splashing and drying. It is harmless in itself, but it is a sign that the EC has been running high. Wipe it down at the two-week change, and check that the EC target is right for the crop and the season.
Plants look pale and the EC is right. The EC measures total salts, not the balance, so a solution can read correctly and still be short of an element the plants need. The usual causes are an old solution that has drifted out of balance, a pH outside the target range that locks out iron or phosphorus, or a product that is not complete. Change the solution, check the pH, and check the label's guaranteed analysis against the element levels in the Cornell handbook. If you are growing in soil as well as hydroponically, a houseplant fertilizer dilution calculator can help you work out the right strength for potted plants, and a garden watering calculator can help you plan how much water the soil beds need.
Beyond the reservoir
Hydroponics is one way to grow, and most growers mix methods. Seedlings started in a hydroponic tray often move to soil, and a greenhouse may hold a nutrient film table next to raised beds. The same habit of measuring before you feed applies everywhere. A potting mix calculator works out how much mix a container needs before you fill it, a raised bed cost calculator prices a new bed before you build it, and a soaker hose calculator works out how long to run a hose so the soil beds get the water they need without waste. The numbers change with the method, but the principle does not: measure, calculate, then mix or water.
Sources
General Hydroponics. Flora Series 3-Part Feed Program. generalhydroponics.com. Light Feed chart, revised 7 July 2026. Source of the reference dose and EC values the calculator uses when the label figures are left blank, and of the mixing-order instructions.
Singh, H., and Dunn, B. Electrical Conductivity and pH Guide for Hydroponics. Oklahoma State University Extension, HLA-6722, published 1 April 2017. extension.okstate.edu. Source of the crop EC and pH ranges, the irrigation-water salt limits, the EC management steps, and the two-week solution replacement advice.
Hooks, T. 2026 Greenhouse Hydroponic Tomato Workshop workbook. University of Arizona Controlled Environment Agriculture Center, January 2026. be.arizona.edu. Source of the tomato recipes by stage, including element concentrations, EC values with and without tap water, and pH.
Brechner, M., and Both, A. J. Cornell CEA Lettuce Handbook. Cornell University Controlled Environment Agriculture Program, 2013. academia.edu. Source of the lettuce set-points, the 35-day schedule, and the final fertilizer solution concentrations.
UF/IFAS Extension. Hydroponic Vegetable Production. HS1422. edis.ifas.ufl.edu. Source of the ideal lettuce EC of 1.4 to 1.8 mS/cm and pH of 6.0 to 7.0.
Bluelab. What are the different conductivity scales? What do they mean? support.bluelab.com. Source of the 500, 650, and 700 scale definitions and the advice to work in EC.
Frequently asked questions
How much nutrient do I add per gallon of water?
It depends on the crop, the growth stage, and the strength of your product. For lettuce at the vegetative stage in a five-gallon reservoir, this calculator gives 12.7 mL per gallon from the reference recipe, 63.5 mL in total. A seedling needs far less, about 5.4 mL per gallon at full reference strength, and a fruiting tomato needs more, about 22.7 mL per gallon. Enter your reservoir size, crop, stage, and your product's label figures, and the calculator works out the dose for your setup.
What EC should hydroponic lettuce be?
Lettuce grows well between 1.0 and 1.5 mS/cm at the vegetative stage, with 1.25 mS/cm as a good starting target. The Cornell CEA lettuce handbook runs lettuce at 1.15 to 1.25 mS/cm above the source-water EC, and UF/IFAS gives 1.4 to 1.8 mS/cm as ideal. Seedlings take a weaker solution, 0.4 to 0.8 mS/cm. Keep the pH between 5.6 and 6.0.
What is the difference between the 500 scale and the 700 scale?
Both scales convert an EC reading to parts per million, but they use different multipliers. The 500 scale multiplies EC by 500, and the 700 scale multiplies EC by 700. A solution at 2.0 mS/cm reads 1000 ppm on the 500 scale and 1400 ppm on the 700 scale. A ppm number without its scale is meaningless, so this calculator asks you to pick the scale before it accepts a ppm target. When in doubt, work in EC: 1 mS/cm is the same on every meter.
Do I need to measure my tap water EC?
Yes, if you want an accurate dose. Tap water carries dissolved salts that add to the EC of the finished solution, and the meter cannot tell them from nutrient salts. Water at 0.4 mS/cm cuts the nutrient dose by about a third for a lettuce reservoir. Water above 1.0 mS/cm is hard or salty water, and the calculator warns you about it: at that level the source water is taking up EC room that the nutrient needs, and reverse osmosis water or a blend is the usual fix.
What order do I mix Micro, Gro, and Bloom?
Always add Micro to the full volume of fresh water first and mix thoroughly, then add Gro second, then add Bloom third, mixing well between each part. Never mix the concentrated parts together undiluted: some salts precipitate when they meet at full strength, and once they have fallen out of solution they do not go back. After all three parts are mixed, check and adjust the EC and pH before feeding.
How often should I change the nutrient solution?
Replace the reservoir solution completely every two weeks, as Oklahoma State Extension advises. The EC reading can look right while the balance of elements has drifted, because plants take up the elements they want most and leave the rest behind. A full change resets the balance. Between changes, top up with plain water when the level falls, and check the EC and pH every day.
Can I use this calculator for a single-bottle nutrient?
Yes. Choose the single concentrate system, enter the label dose and the EC that dose produces, and the calculator gives one dose in milliliters per gallon. If you leave the label figures blank, the calculator uses the reference recipe totals for the stage, which come from the General Hydroponics Light Feed chart. Replace them with your own product's label figures whenever you know them, because every product has its own strength.
Why is my EC reading different from what the calculator predicted?
The most common causes are a reservoir volume that is not what you think, source water with an EC you did not measure, or label figures that do not match the product in the bottle. Measure the reservoir once with a gallon jug, measure the source water with the meter before adding anything, and check the label dose and label EC you entered. Small differences are normal: the meter reading after mixing is the check that matters, so add water if the reading is high and add concentrate a little at a time if it is low.