WHO Air Quality Guideline Checker
Verified Last reviewed: 22 November 2026. Page history
WHO air quality guideline check
How the numbers were worked out
Check the rest of the picture: our Air Purifier Size Calculator sizes a purifier for the room you breathe in, and our Humidifier Size and Runtime Finder sizes a humidifier for dry indoor air. For the exercise question, an AQI Outdoor Exercise Safety Checker is planned as a companion to this tool.
Notes and how it works
Pollutant
The six pollutants the WHO 2021 guidelines cover. PM2.5 is the one most home sensors report.
Averaging period
The period your reading covers. The options change with the pollutant, because WHO sets different periods for different pollutants.
Concentration (µg/m³)
In micrograms per cubic meter, 0 to 10,000. Decimals are fine: 37.5 counts as 37.5. Carbon monoxide is entered in milligrams per cubic meter instead.
Free to use — no sign-up, no paywall. Spotted a mistake? Tell us — we fix reported errors within 24 hours.
Your inputs stay in your browser: every calculation runs on your device, and nothing you type is sent to our servers.
Last reviewed: 22 November 2026. Reviewed every 180 days; next review due 22 May 2027.
How to use the WHO Air Quality Guideline Checker
Your sensor says PM2.5 is 35. Your weather app says ozone is 0.070 ppm. A wildfire smoke forecast says PM2.5 will reach 150 tomorrow. Those numbers mean nothing until they are measured against a standard, and the standard most of the world uses is the World Health Organization guideline. In September 2021, WHO published its first update in 16 years, and it cut almost every guideline level sharply: the annual PM2.5 guideline fell from 10 to 5 micrograms per cubic meter, and the annual nitrogen dioxide guideline fell from 40 to 10. This checker takes a reading you already have, from a home sensor, a local monitor, or a forecast, and places it against the WHO 2021 table: it tells you whether the air meets the guideline, which interim target it meets if it does not, and how many times the guideline the reading is. It also shows the US EPA standard for the same pollutant and averaging period, so you can see the two standards side by side.
The answer is a comparison, not a verdict on your health. The tool describes the air: a reading of 40 micrograms per cubic meter of PM2.5 over 24 hours is 2.7 times the WHO guideline and meets interim target IT-2. It does not say whether the air is safe for you, because safety depends on who is breathing it, for how long, and with what health history. What it gives you is the honest position of one number against the two standards that matter in the United States: the WHO guideline, which is the health-based level, and the EPA standard, which is the legally enforceable one.
To get your result, follow these steps:
- Pick a pollutant. The six pollutants the WHO 2021 guidelines cover: PM2.5 (fine particles), PM10 (inhalable particles), ozone, nitrogen dioxide, sulfur dioxide, and carbon monoxide. PM2.5 is the one most home sensors report, and it is the default. If your sensor reports an AQI number instead of a concentration, this is the wrong tool for that number: AQI is a separate index, and a companion AQI checker is planned.
- Pick the averaging period. The options change with the pollutant, because WHO sets different periods for different pollutants. PM2.5, PM10, and nitrogen dioxide have annual and 24-hour guidelines. Ozone has a peak-season guideline and an 8-hour guideline. Sulfur dioxide and carbon monoxide have 24-hour guidelines only. Match the period to your reading: a one-day average goes against the 24-hour guideline, and a year of data goes against the annual guideline. A one-hour reading cannot be checked against a 24-hour average, and the tool does not pretend it can.
- Enter the concentration. In micrograms per cubic meter for every pollutant except carbon monoxide, which WHO measures in milligrams per cubic meter: the field label changes to mg/m³ when you pick carbon monoxide, so the unit is always in front of you. Decimals are fine: 37.5 counts as 37.5. The range runs from 0 to 10,000 micrograms per cubic meter, or 0 to 1,000 milligrams per cubic meter for carbon monoxide, which covers everything from clean mountain air to the worst wildfire smoke.
- Read the result. The headline gives the band: meets the guideline, meets an interim target, or above interim target IT-1. The cards show the WHO guideline, your band, the multiple of the guideline, the next target down, the EPA standard, and the EPA comparison. The guidance explains the result in plain language, including what the pollutant is and what the evidence behind the guideline covers. The warnings flag the specific cases that matter: a reading above IT-1, a reading above the EPA standard, or a zero reading, which usually means the sensor reported no data. The steps print the full working so you can check every figure.
The tool updates as you type, so you can try different numbers quickly. Try the example buttons under the form: a PM2.5 24-hour reading of 12 that meets the guideline, a PM2.5 24-hour reading of 40 that meets interim target IT-2, a PM2.5 annual reading of 12 that meets interim target IT-3, and an ozone 8-hour reading of 180 that is above interim target IT-1. The worked examples below show the full working for each one, plus a carbon monoxide example.
Read the full result, not just the headline. Two readings can sit in the same band and be very different: a PM2.5 24-hour reading of 26 and a reading of 37 both meet interim target IT-3, but the second is nearly half as high again, and the multiple tells you so. The EPA comparison matters too, because the EPA standard is looser than the WHO guideline on every row they share: a reading can meet the EPA standard and still be far above the WHO guideline, and the tool shows both facts at once.
How it works
The calculator takes three inputs, looks up the WHO 2021 row for that pollutant and averaging period, places the reading against the guideline and the interim targets, works out the multiple of the guideline, and looks up the EPA standard for the same row. Every figure comes from the published tables, re-checked against the WHO and EPA pages on 22 November 2026. Nothing is estimated, and nothing is fetched live: the numbers you enter never leave your browser, and the tool works the same way with no connection at all once the page has loaded.
Step 1: the WHO 2021 table
The WHO global air quality guidelines, published 22 September 2021, set guideline levels for six pollutants across ten pollutant-and-period rows: PM2.5 annual and 24-hour, PM10 annual and 24-hour, ozone peak-season and 8-hour, nitrogen dioxide annual and 24-hour, sulfur dioxide 24-hour, and carbon monoxide 24-hour. Each row has one guideline level, the AQG, which is the lowest level in the table for that row, and one to four interim targets above it. The guideline is the level WHO recommends on the evidence: the lowest exposure level at which the evidence shows harm to health. The table below lists all ten rows with every value.
The 2021 update was the first since 2005, and it was built on six systematic reviews covering more than 500 papers. WHO adjusted almost every level downward, warning that exceeding the new levels is associated with significant risks to health, and that adhering to them could save millions of lives. Air pollution is estimated to cause 7 million premature deaths a year, and in 2019 more than 90 percent of the global population lived in areas where concentrations exceeded even the old 2005 PM2.5 guideline. WHO's own scenario analysis found that almost 80 percent of deaths related to PM2.5 could be avoided if current levels were reduced to the updated guideline.
Step 2: interim targets, the stepping stones
Interim targets exist because the guideline is a long way off for much of the world. WHO sets them as milestones: IT-1 is the loosest and the first step, IT-4 is the strictest and the last step before the guideline. A city at IT-1 has a long way to go; a city at IT-4 is nearly there. The number of targets varies by row, because WHO only sets targets where the evidence supports them: PM2.5 has four targets on both its rows, PM10 has four, nitrogen dioxide has three on its annual row and two on its 24-hour row, ozone has two on both its rows, sulfur dioxide has two, and carbon monoxide has one.
The band rule is simple and exact. A reading at or below the guideline meets the guideline. A reading above the guideline meets the lowest interim target it sits at or below: a PM2.5 24-hour reading of 40 is above the IT-3 value of 37.5 and at or below the IT-2 value of 50, so it meets IT-2. A reading above IT-1, the highest interim target, is above every target WHO sets for that row. A reading exactly at a threshold meets that threshold: 15 micrograms per cubic meter of PM2.5 over 24 hours meets the guideline, and 50 meets IT-2.
Step 3: the 99th percentile rule
The 24-hour and 8-hour WHO values are 99th-percentile levels, which means 3 to 4 days a year may exceed them without breaking the guideline. The guideline is written against the distribution of daily values across a year, not against any single day. A single day above the 24-hour value does not by itself mean the guideline is breached: it means that day was one of the handful of high days the guideline allows. The annual values work differently: they are means across the whole year, so a few bad days matter less and a bad season matters more. The tool notes the 99th percentile rule on every 24-hour and 8-hour result, and the peak-season definition on every peak-season result: the average of daily maximum 8-hour mean ozone concentrations over the six consecutive months with the highest six-month running average.
Step 4: the multiple
The multiple is the reading divided by the guideline, and it is the fastest way to feel the size of a number. A PM2.5 24-hour reading of 40 is 40 divided by 15, which is 2.7 times the guideline. A reading of 12 is 0.8 times the guideline, which is 80 percent of it. The multiple is shown to one decimal place, except that a small reading whose one-decimal multiple would print as 0 gets two decimals, so a PM2.5 annual reading of 0.2 shows as 0.04 times the guideline rather than 0 times. The percent of the guideline is shown alongside it: 2.7 times is 266.7 percent, and 0.8 times is 80 percent.
Step 5: the EPA comparison
The EPA column shows the US EPA National Ambient Air Quality Standard for the same pollutant and averaging period, taken from the EPA NAAQS table. The comparison only runs where the EPA sets a standard for the same period, which is five of the ten rows: PM2.5 annual (9.0 micrograms per cubic meter), PM2.5 24-hour (35), PM10 24-hour (150), ozone 8-hour (0.070 ppm), and nitrogen dioxide annual (53 ppb). The other five rows have no EPA standard for their averaging period, and the tool says so plainly instead of inventing a comparison: there is no EPA annual PM10 standard, no EPA peak-season ozone standard, no EPA 24-hour nitrogen dioxide standard, no EPA 24-hour sulfur dioxide standard, and no EPA 24-hour carbon monoxide standard.
Two of the EPA standards are published in ppb, not micrograms per cubic meter, so the tool converts them at 25 °C and 1 atmosphere using the gas law: micrograms per cubic meter equals ppb times molecular weight divided by 24.45. Nitrogen dioxide at 53 ppb works out to about 100 micrograms per cubic meter, and ozone at 70 ppb works out to about 137. Both converted figures are labelled approximate wherever they appear, because the true value shifts a little with temperature and pressure. The direct microgram-per-cubic-meter standards, PM2.5 and PM10, need no conversion and are shown exactly as the EPA publishes them.
The WHO 2021 guideline table
All values in micrograms per cubic meter, except carbon monoxide, which is in milligrams per cubic meter. A dash means WHO sets no target at that step for that row.
| Pollutant | Averaging period | WHO guideline | IT-1 | IT-2 | IT-3 | IT-4 |
|---|---|---|---|---|---|---|
| PM2.5 | Annual | 5 | 35 | 25 | 15 | 10 |
| PM2.5 | 24-hour | 15 | 75 | 50 | 37.5 | 25 |
| PM10 | Annual | 15 | 70 | 50 | 30 | 20 |
| PM10 | 24-hour | 45 | 150 | 100 | 75 | 50 |
| Ozone (O3) | Peak season | 60 | 100 | 70 | - | - |
| Ozone (O3) | 8-hour | 100 | 160 | 120 | - | - |
| Nitrogen dioxide (NO2) | Annual | 10 | 40 | 30 | 20 | - |
| Nitrogen dioxide (NO2) | 24-hour | 25 | 120 | 50 | - | - |
| Sulfur dioxide (SO2) | 24-hour | 40 | 125 | 50 | - | - |
| Carbon monoxide (CO) | 24-hour | 4 mg/m³ | 7 mg/m³ | - | - | - |
Two values from the 2005 guidelines were not re-evaluated in 2021 and remain in force: the nitrogen dioxide 1-hour guideline of 200 micrograms per cubic meter, and the sulfur dioxide 10-minute guideline of 500 micrograms per cubic meter. They are reference values, not rows in the checker, because the checker covers the ten 2021 rows. They appear as notes on nitrogen dioxide and sulfur dioxide results.
What changed between 2005 and 2021 tells the story of the evidence. The PM2.5 annual guideline halved, from 10 to 5, and the 24-hour guideline fell from 25 to 15. The PM10 annual guideline fell from 20 to 15, and the 24-hour guideline from 50 to 45. The nitrogen dioxide annual guideline fell to a quarter of its old value, from 40 to 10, and the 24-hour guideline of 25 is new. The ozone 8-hour guideline stayed at 100, and the peak-season guideline of 60 is new. Carbon monoxide had no 2005 guideline at all: the 24-hour guideline of 4 milligrams per cubic meter is new in 2021. Sulfur dioxide is the one exception to the tightening: the 2005 24-hour guideline was 20, and the 2021 review set it at 40 on the newer evidence. The direction of travel is clear even with that exception: the science found harm at lower concentrations than anyone had measured before, and the guidelines followed the science down.
Where both PM2.5 and PM10 readings are available, WHO gives priority to PM2.5, because the fine particles carry the stronger evidence. The two are related but not interchangeable: PM10 includes PM2.5 plus the coarser particles between 2.5 and 10 micrometers, so a PM10 reading is always at least as high as the PM2.5 reading from the same air. Checking both is useful; if they disagree, the PM2.5 result governs.
WHO vs EPA: the same air, two standards
The EPA standard is looser than the WHO guideline on every row they share. The table below puts the two side by side, with the EPA standard expressed as a multiple of the WHO guideline. A multiple of 10 means the EPA allows ten times the concentration WHO recommends.
| Pollutant and period | WHO guideline | EPA standard | EPA as a multiple of WHO |
|---|---|---|---|
| PM2.5, annual | 5 µg/m³ | 9.0 µg/m³ | 1.8 times |
| PM2.5, 24-hour | 15 µg/m³ | 35 µg/m³ | 2.3 times |
| PM10, annual | 15 µg/m³ | No EPA standard | - |
| PM10, 24-hour | 45 µg/m³ | 150 µg/m³ | 3.3 times |
| Ozone, peak season | 60 µg/m³ | No EPA standard | - |
| Ozone, 8-hour | 100 µg/m³ | 0.070 ppm (about 137 µg/m³) | 1.4 times |
| NO2, annual | 10 µg/m³ | 53 ppb (about 100 µg/m³) | 10 times |
| NO2, 24-hour | 25 µg/m³ | No EPA standard | - |
| SO2, 24-hour | 40 µg/m³ | No EPA standard | - |
| CO, 24-hour | 4 mg/m³ | No EPA standard | - |
The nitrogen dioxide gap is the widest: the EPA annual standard of 53 ppb, about 100 micrograms per cubic meter, is ten times the WHO guideline of 10. A city can meet the EPA nitrogen dioxide standard comfortably while sitting far above the WHO guideline, and the checker shows that plainly: a nitrogen dioxide annual reading of 41 is above interim target IT-1 on the WHO table and still well under the EPA standard. The PM10 gap is the next widest at 3.3 times, then PM2.5 24-hour at 2.3 times, PM2.5 annual at 1.8 times, and ozone 8-hour at 1.4 times, the narrowest gap of the five.
The gap exists because the two bodies answer different questions. WHO asks what level the health evidence supports, and nothing else. The EPA asks what level protects public health while surviving a legal process that weighs feasibility, cost, and the state of monitoring: its standards are set by rulemaking under the Clean Air Act, reviewed on a schedule, and enforceable in court. The EPA standard has also moved: the annual PM2.5 standard was 12 micrograms per cubic meter until the EPA lowered it to 9.0, which narrowed the gap with WHO from 2.4 times to 1.8 times. WHO guidelines are not legally binding anywhere; they are the benchmark countries are urged to aim for. EPA standards are law in the United States. Both facts matter, and the checker keeps them separate: the WHO band is the health comparison, and the EPA comparison is the legal one.
The five rows with no EPA standard deserve a plain statement, because a missing standard is easy to misread as a clean bill of health. There is no EPA annual PM10 standard, no EPA peak-season ozone standard, no EPA 24-hour nitrogen dioxide standard, no EPA 24-hour sulfur dioxide standard, and no EPA 24-hour carbon monoxide standard. The EPA covers those pollutants on other averaging periods instead: PM10 over 24 hours, ozone over 8 hours, nitrogen dioxide over 1 hour and 1 year, sulfur dioxide over 1 hour, and carbon monoxide over 8 hours and 1 hour. A reading on a period the EPA does not cover has no EPA comparison to make, and the tool says so rather than comparing across periods, which would be comparing unlike with unlike.
Worked examples
Each example was recomputed by hand directly from the source tables, independently of the engine, and all five match the engine output exactly.
Example 1: PM2.5, 24-hour, 12 µg/m³
WHO guideline: 15 µg/m³. Interim targets: IT-1 75, IT-2 50, IT-3 37.5, IT-4 25. The reading of 12 is at or below 15, so it meets the WHO guideline. Multiple: 12 divided by 15 is 0.8 times the guideline, which is 80 percent of it. Below the guideline by 3 µg/m³. There is no stricter target to aim for. EPA standard: 35 µg/m³, and 12 meets it. This is a clean day by both standards, the kind of reading a home sensor shows on a clear day with no smoke and light traffic.
Example 2: PM2.5, 24-hour, 40 µg/m³
WHO guideline: 15 µg/m³. The reading of 40 is above the IT-3 value of 37.5 and at or below the IT-2 value of 50, so it meets interim target IT-2. Multiple: 40 divided by 15 is 2.7 times the guideline, which is 266.7 percent of it. Above the guideline by 25 µg/m³. The next target down is IT-3 at 37.5, and the concentration would need to fall by 2.5 µg/m³ to reach it. EPA standard: 35 µg/m³, and 40 is above it, at 1.1 times the EPA standard. This is a hazy day, or a day downwind of a fire: above the EPA standard as well as the WHO guideline, but still inside the interim targets.
Example 3: PM2.5, annual, 12 µg/m³
WHO guideline: 5 µg/m³. Interim targets: IT-1 35, IT-2 25, IT-3 15, IT-4 10. The reading of 12 is above the IT-4 value of 10 and at or below the IT-3 value of 15, so it meets interim target IT-3. Multiple: 12 divided by 5 is 2.4 times the guideline, which is 240 percent of it. Above the guideline by 7 µg/m³. The next target down is IT-4 at 10, and the concentration would need to fall by 2 µg/m³ to reach it. EPA standard: 9.0 µg/m³, and 12 is above it, at 1.3 times the EPA standard. This is the shape of a typical American city year: above both standards, but within the interim targets, and two steps from the guideline.
Example 4: Ozone, 8-hour, 180 µg/m³
WHO guideline: 100 µg/m³. Interim targets: IT-1 160, IT-2 120. The reading of 180 is above IT-1 of 160, so it is above every interim target WHO sets for this row. Multiple: 180 divided by 100 is 1.8 times the guideline, which is 180 percent of it. Above the guideline by 80 µg/m³. The next target down is IT-1 at 160, and the concentration would need to fall by 20 µg/m³ to reach it. EPA standard: 0.070 ppm, about 137 µg/m³ at 25 °C, and 180 is above it, at 1.3 times the EPA standard. This is a hot, sunny, high-ozone afternoon: above both standards and above every WHO interim target.
Example 5: Carbon monoxide, 24-hour, 5.5 mg/m³
WHO guideline: 4 mg/m³. Interim target: IT-1 7 mg/m³, the only interim target on this row. The reading of 5.5 is above the guideline of 4 and at or below IT-1 of 7, so it meets interim target IT-1. Multiple: 5.5 divided by 4 is 1.4 times the guideline, which is 137.5 percent of it. Above the guideline by 1.5 mg/m³. The next target down is the guideline itself at 4, and the concentration would need to fall by 1.5 mg/m³ to reach it. EPA standard: none for the 24-hour period. The EPA carbon monoxide standards cover 8 hours, at 9 ppm, and 1 hour, at 35 ppm. Carbon monoxide is the one pollutant WHO measures in milligrams per cubic meter: 5.5 mg/m³ is 5,500 µg/m³, and entering it as 5,500 in the microgram field of another pollutant would be a different question entirely.
Features
- All ten WHO rows, not just PM2.5. Every pollutant and averaging period in the WHO 2021 table is covered: both PM rows, both ozone rows, both nitrogen dioxide rows, sulfur dioxide, and carbon monoxide, with the interim targets for each.
- A band, not just a number. The result says whether the reading meets the guideline, which interim target it meets, or whether it is above IT-1, with the next target down and the fall needed to reach it.
- The multiple, stated plainly. Every result shows how many times the guideline the reading is, to one decimal place, with the percent alongside, so the size of the number is visible at a glance.
- The EPA standard alongside. Where the EPA sets a standard for the same period, the result shows it, says whether the reading meets it, and gives the multiple. Where it does not, the result says so and names the periods the EPA does cover.
- Honest unit handling. Carbon monoxide is entered in milligrams per cubic meter, as WHO publishes it, and the field label changes when you pick it. The ppb-to-microgram conversions for the EPA gas standards are labelled approximate wherever they appear.
- Full working printed. Every step of the comparison is printed on the result, including the 99th percentile rule and the peak-season definition where they apply, so any figure can be checked by hand against the tables below.
- Private by design. The numbers you enter never leave your browser. There is no live feed, no location lookup, and no account: the tool compares a number you typed with tables stored in the page.
Use cases
- Reading a home sensor. A PurpleAir or IQAir sensor reports PM2.5 in micrograms per cubic meter. Enter the 24-hour average to see where the day sits against the WHO guideline and the EPA standard, and enter the yearly average to see where the year sits.
- Wildfire smoke days. During a smoke event, PM2.5 readings can pass 100, 200, or higher. The checker shows how far above IT-1 the air has gone and how many times the guideline the reading is, which is more useful than a bare number when deciding whether to keep windows closed.
- Checking a city before moving. City air quality reports publish annual averages. Enter the annual PM2.5 and nitrogen dioxide figures for two cities to compare them on the same WHO scale, instead of comparing bare numbers with no standard behind them.
- Reading a forecast. Air quality forecasts publish expected concentrations. Enter the forecast PM2.5 or ozone figure to see which band the coming day falls in, and whether it clears the EPA standard as well as the WHO guideline.
- Understanding a news story. When a story says a city recorded PM2.5 of 80, enter 80 as a 24-hour reading: it is above IT-1 of 75 and 5.3 times the WHO guideline, which says more in one line than the bare number does.
- Classroom and community work. The tables and the worked examples give students and community groups a way to place local monitoring data against the world standard, with the EPA comparison showing where the United States sets its own bar.
Sources
Every figure in this tool was re-verified against the publisher's own live page on 22 November 2026. The brief's figures were research notes; the publishers govern.
- WHO global air quality guidelines: particulate matter (PM2.5 and PM10), ozone, nitrogen dioxide, sulfur dioxide and carbon monoxide (published 22 September 2021): the guideline document itself, source of the ten rows, the interim targets, and the 99th percentile rule.
- World Health Organization Global Air Quality Guideline Recommendations: Executive Summary (Goshua, Akdis and Nadeau, Allergy 2022): Table 1 reproduces the full AQG and interim target table, including the footnotes on the 99th percentile and the peak-season definition, and confirms that previously established WHO AQGs for averaging times not addressed in 2021 remain valid.
- WHO news release, 22 September 2021: the context figures used on this page, including 7 million premature deaths a year, more than 90 percent of the global population above the 2005 PM2.5 guideline in 2019, almost 80 percent of PM2.5-related deaths avoidable at the updated guideline, and six systematic reviews covering more than 500 papers.
- US EPA NAAQS Table: every EPA figure in the comparison column, including PM2.5 annual 9.0 and 24-hour 35, PM10 24-hour 150, ozone 8-hour 0.070 ppm, nitrogen dioxide 1-hour 100 ppb and annual 53 ppb, sulfur dioxide 1-hour 75 ppb, and carbon monoxide 8-hour 9 ppm and 1-hour 35 ppm, and the absence of EPA standards for the five uncovered periods.
- WHO Air quality guidelines, global update 2005: summary of risk assessment: the 2005 values cited in the history section, including PM2.5 annual 10 and 24-hour 25, PM10 annual 20 and 24-hour 50, nitrogen dioxide annual 40 and 1-hour 200, ozone 8-hour 100, and sulfur dioxide 24-hour 20 and 10-minute 500.
Conflicts resolved. (1) The executive summary's section 1.3 text calls the ozone value of 100 a "24-hour exposure" figure, but its own Table 1 and the guideline define it as the 8-hour value, the 99th percentile of daily maximum 8-hour means. The tool uses 8-hour, per Table 1. (2) The EPA sets no standard for five of the ten WHO rows. The tool reports no EPA comparison on those rows and names the periods the EPA does cover, rather than comparing across averaging periods. (3) The EPA publishes its ozone and nitrogen dioxide standards in ppb, so the tool converts them to micrograms per cubic meter at 25 °C and 1 atmosphere with the gas law, and labels the converted figures approximate wherever they appear. (4) One widely copied summary of the 2021 guidelines lists wrong values for PM10 annual, ozone 8-hour, sulfur dioxide 24-hour, and carbon monoxide; the tool follows the WHO Table 1 values, verified against the executive summary, not the summary. (5) WHO's own AirQ+ software is expert desktop software for health-impact assessment, used with the support of an epidemiologist, and it is not a consumer checker: this tool does not duplicate it, and it does not try to do what AirQ+ does.
Related tools: the Air Purifier Size Calculator sizes a purifier for the room you breathe in, and the Humidifier Size and Runtime Finder sizes a humidifier for dry indoor air. An AQI Outdoor Exercise Safety Checker is planned as a companion to this tool, for the question of whether to exercise outdoors on a given day.
Frequently asked questions
What is a good PM2.5 level according to WHO?
WHO sets two PM2.5 levels: an annual average of 5 micrograms per cubic meter, and a 24-hour average of 15. A reading at or below those levels meets the guideline. A 24-hour reading between 15 and 25 meets interim target IT-4, between 25 and 37.5 meets IT-3, between 37.5 and 50 meets IT-2, and between 50 and 75 meets IT-1. Above 75 is above every interim target WHO sets. The annual levels are stricter because they describe a whole year of exposure: an annual average of 12, which is common in American cities, is 2.4 times the guideline and meets interim target IT-3. Most of the world lives above the guideline: in 2019, more than 90 percent of the global population lived in areas exceeding even the old 2005 annual guideline of 10.
What are WHO interim targets?
Interim targets are stepping stones between dirty air and the guideline. WHO knows the guideline is a long way off for much of the world, so it sets intermediate levels that still bring health benefits as air improves. IT-1 is the loosest and the first step; IT-4 is the strictest and the last step before the guideline. For PM2.5 annual, the targets are 35, 25, 15, and 10 on the way to the guideline of 5. Meeting IT-1 is progress, not arrival: a reading that meets IT-1 is still seven times the guideline. The number of targets varies by row, because WHO only sets targets where the evidence supports them. Carbon monoxide has one target, ozone has two, and PM2.5 has four.
How does the WHO guideline compare with the US EPA standard?
The EPA standard is looser than the WHO guideline on every row they share. The annual PM2.5 standard of 9.0 micrograms per cubic meter is 1.8 times the WHO guideline of 5. The 24-hour PM2.5 standard of 35 is 2.3 times the WHO guideline of 15. The 24-hour PM10 standard of 150 is 3.3 times the WHO guideline of 45. The 8-hour ozone standard of 0.070 ppm, about 137 micrograms per cubic meter, is 1.4 times the WHO guideline of 100. The widest gap is nitrogen dioxide: the EPA annual standard of 53 ppb, about 100 micrograms per cubic meter, is ten times the WHO guideline of 10. On five of the ten WHO rows the EPA sets no standard at all for that averaging period, so there is nothing to compare. The gap exists because WHO answers a health question only, while the EPA sets standards by rulemaking under the Clean Air Act, weighing feasibility and cost alongside health, and its standards are legally enforceable.
What does the 99th percentile mean for the 24-hour values?
The 24-hour and 8-hour WHO values are 99th-percentile levels, which means 3 to 4 days a year may exceed them without breaking the guideline. The guideline is written against the distribution of daily values across a year, not against any single day. A single day above the 24-hour value does not by itself mean the guideline is breached: it means that day was one of the handful of high days the guideline allows. If high days keep coming, the 99th percentile rises, and that is when the guideline is breached. The annual values work differently: they are means across the whole year, so a few bad days matter less and a bad season matters more.
Is PM2.5 of 35 bad?
As a 24-hour average, 35 micrograms per cubic meter sits above the WHO guideline of 15 and meets interim target IT-3, whose value is 37.5. It is 2.3 times the guideline. It is also exactly the US EPA 24-hour standard of 35, so it meets the EPA standard while sitting well above the WHO guideline. That split is the whole point of showing both standards: the same air can pass one test and fail the other. As an annual average, 35 would be far worse: it would meet interim target IT-1 and sit seven times the annual guideline of 5. The averaging period changes the answer, which is why the tool asks for it.
What is the WHO ozone guideline?
WHO sets two ozone levels: an 8-hour average of 100 micrograms per cubic meter, and a peak-season average of 60. Peak season means the average of daily maximum 8-hour mean ozone concentrations over the six consecutive months with the highest six-month running average, which is roughly the warm half of the year, when sunlight drives ozone formation. The interim targets are 160 and 120 for the 8-hour row, and 100 and 70 for the peak-season row. The 8-hour value is a 99th-percentile level, so 3 to 4 days a year may exceed it. Ozone is the only pollutant with a peak-season row, because it is the only one whose health evidence is strong enough to support a seasonal average.
Why is carbon monoxide measured in mg/m³?
Because carbon monoxide concentrations are about a thousand times higher in mass terms than the other pollutants. The WHO 24-hour guideline for carbon monoxide is 4 milligrams per cubic meter, which is 4,000 micrograms per cubic meter. Writing it in micrograms would mean four-digit numbers for ordinary readings, so WHO publishes it in milligrams, and this tool follows the table. The conversion is simple: 1 milligram is 1,000 micrograms. Enter carbon monoxide in milligrams per cubic meter: a reading of 5.5 mg/m³ is 5,500 µg/m³, and entering 5,500 in a microgram field would be a different question entirely. Carbon monoxide is also the only pollutant with a single interim target, IT-1 at 7 mg/m³.
Does this tool tell me if the air is safe for me?
No. This tool compares a number you entered with published guideline levels, and it describes the air, not any person. Whether air is safe for you depends on who is breathing it, for how long, and with what health history, and no web tool can answer that. The guideline levels are set for populations, and the evidence behind them covers heart and lung disease across whole communities. For official air quality information about your area, check your local air quality agency or AirNow, which reports the US Air Quality Index. The general public-health advice for high-pollution days is to reduce strenuous outdoor exertion and keep windows closed during smoke events, and anyone with breathing or heart trouble should follow their clinician's advice.
Page history
- — Published (saleem891@gmail.com)