Firewood Cord Calculator
Verified Last reviewed: 21 November 2026. Page history
Cords for the winter
How the numbers were worked out
Cords by species, same home and appliance
Keep planning the woodpile: our Firewood BTU Calculator works out the heat in the cords you already have, our Log Board Foot Calculator measures the lumber in a log before you cut it for firewood, our Tree Height Calculator measures a tree before you fell it, and our Mini-Split BTU Sizer sizes electric heat for the rooms wood does not reach.
Free to use — no sign-up, no paywall. Spotted a mistake? Tell us — we fix reported errors within 24 hours.
Your inputs stay in your browser: every calculation runs on your device, and nothing you type is sent to our servers.
Last reviewed: 21 November 2026. Reviewed every 180 days; next review due 19 May 2027.
How to use the Firewood Cord Calculator
How many cords of firewood do you need for the winter? The honest answer is that it depends on four things: the size of your home, how cold your winters are, how well your home holds heat, and what you burn the wood in. A 1,000 square foot cabin in Georgia and a 2,500 square foot farmhouse in Minnesota are not the same problem, and a cord burned in an open fireplace gives less than a fifth of the heat the same cord gives in a modern wood stove. This calculator works through all four factors with one published formula, and it shows every step of the arithmetic so you can check the answer by hand.
The calculator starts from heating degree days, the standard measure of how cold a climate is over a full year. It multiplies your home size by your heating degree days and by a heat-loss factor for your insulation, which gives the heat your home needs for the winter in million BTU. It then divides that heat by the usable heat in one cord of your wood, which is the published heat value of your species times the efficiency of your appliance. The result is the exact number of cords, and the calculator rounds up to whole cords, because that is how firewood is sold. It also works out the face cords, the stacked volume, the length of the stack, the ground it covers, and the season cost when you enter a price per cord.
To get your result, follow these steps:
- Enter your heated home size. Enter the floor area the wood heat has to warm, from 100 to 10,000 square feet. If the stove heats the whole house, enter the whole house. If it heats one room only, enter that room: the calculator sizes the wood to the space the wood actually heats, and heating one room uses far less wood than heating a whole house.
- Pick your climate zone. The five zones run from Mild, about 2,500 heating degree days, to Extreme, about 10,500. Each zone names example cities so you can place yourself: Atlanta and Phoenix are Mild, St. Louis and Baltimore are Moderate, Chicago, Boston, and Detroit are Cold, Minneapolis and Bismarck are Very cold, and Duluth and Anchorage are Extreme. If you know your own heating degree days from NOAA climate data for your city, enter the figure in the optional box and the calculator uses it instead of the zone figure.
- Pick your insulation. A well-insulated, tight modern home loses less heat per square foot than an average home, and a drafty older home loses half as much again. The three levels are the biggest lever on the answer after the appliance: moving from average to drafty insulation adds 50% to the cord count for the same home and climate.
- Say how much of your heat comes from wood. If wood is your primary heat, pick all of it. If a furnace or heat pump carries part of the load, pick the share wood supplies: most of it at about 75%, about half at 50%, or occasional fires at about 25%. Halving the share halves the cords, because the calculator sizes the wood to the heat the wood has to supply.
- Pick your wood species. The list holds the 16 species in the Penn State Extension table, hottest first, from Osage orange at 30.7 million BTU per cord down to red and silver maple at 18.7 million BTU per cord. If your wood is a species the table does not cover, such as pine, fir, or spruce, pick "My own wood" and enter its heat value from a published extension table. White pine is 14.3 and hemlock is 15.9 million BTU per cord in the Virginia Tech table.
- Pick what you burn it in. This is the step most firewood guides skip, and it matters more than the species. A modern wood stove delivers 80% of the heat in the wood to the room. An EPA-certified fireplace insert delivers 65%. A wood furnace delivers 75%. An open fireplace delivers only 15%. If you know your appliance rating from its rating plate, pick "My own efficiency figure" and enter it.
- Enter the price per cord, if you want the cost. This step is optional. Enter what you pay for one full cord, delivered or picked up, and the calculator shows the season cost and the cost per million BTU of delivered heat. The cost per million BTU of delivered heat is the fair way to compare two offers: dearer wood that burns hotter can cost less per unit of heat than cheap wood.
- Read the comparison table. Below the headline result, the calculator shows all 16 species with the cords each would need for the same home and appliance, hottest first. It is the fastest way to answer the question "how much wood do I save by burning oak instead of maple" in one glance.
Three worked examples show the arithmetic. First, the default case: a 1,500 square foot home in a Cold climate with average insulation, heated entirely with red oak in a modern wood stove. The heat load is 1,500 times 6,500 times 8, which is 78.00 million BTU. Each cord of red oak in a stove at 80% efficiency delivers 24.0 times 80%, which is 19.20 million BTU. The cords needed are 78.00 divided by 19.20, which is 4.06 cords, so you buy 5 cords. At $250 a cord, the season costs $1,250.00.
Second, a 2,000 square foot drafty farmhouse in a Very cold climate, heated entirely with hickory in a wood furnace at 75% efficiency, at $275 a cord. The heat load is 2,000 times 8,500 times 12, which is 204.00 million BTU. Each cord of hickory in the furnace delivers 28.0 times 75%, which is 21.00 million BTU. The cords needed are 204.00 divided by 21.00, which is 9.71 cords, so you buy 10 cords. The season costs 10 times $275, which is $2,750.00, and the cost per million BTU of delivered heat is $275 divided by 21.00, which is $13.10.
Third, a 1,000 square foot cabin in a Mild climate with average insulation, where white pine in an open fireplace supplies half the heat. The total heat load is 1,000 times 2,500 times 8, which is 20.00 million BTU, and wood supplies 50% of it, which is 10.00 million BTU. Each cord of white pine in a fireplace at 15% efficiency delivers 14.3 times 15%, which is 2.15 million BTU. The cords needed are 10.00 divided by 2.15, which is 4.65 cords, so you buy 5 cords. The same cabin with a modern stove at 80% efficiency would need only 0.87 cords, because each cord of pine in a stove delivers 11.44 million BTU. That gap is the whole story of firewood heating: the appliance decides the answer.
How the calculator works
The calculator runs on one formula, the standard heating-degree-day method for sizing firewood: cords equal the heat the home needs, divided by the usable heat in one cord of your wood. The heat the home needs is the home size times the heating degree days times a heat-loss factor for insulation, times the share of the heat that comes from wood. The usable heat in one cord is the published heat value of the species times the efficiency of the appliance. Every number in the formula comes from a published source or from a calibration the sources below document, and the results page shows the working line by line.
The first part of the formula is the heat load. Heat load equals home size in square feet, times heating degree days, times the heat-loss factor in BTU per square foot per heating degree day, divided by one million to give million BTU. For the default case, 1,500 square feet times 6,500 heating degree days times 8 BTU per square foot per heating degree day is 78,000,000 BTU, which is 78.00 million BTU. If wood supplies only part of the heat, the load is multiplied by the share: at 50%, the wood has to supply 78.00 times 50%, which is 39.00 million BTU.
Heating degree days measure how cold a climate is over a full year. For each day that the average outdoor temperature falls below 65 degrees Fahrenheit, the difference between 65 and that average is added to the yearly total. A day averaging 35 degrees adds 30 heating degree days. A warm climate racks up few degree days, a cold one racks up many, and the total tracks the heating bill far better than the coldest night of the year. The 65 degree base is the United States standard, used by NOAA and by the building codes.
The five climate zones in the calculator use midpoints drawn from the published city figures. The table below shows the zone, the midpoint the calculator uses, and the published city figures behind it, from the ICC Appendix D degree-day table and the Engineering Toolbox United States heating degree-day table, both re-checked on 21 November 2026.
| Climate zone | Heating degree days used | Zone range | Example cities, published figures |
|---|---|---|---|
| Mild | 2,500 | Under 3,500 | Atlanta 2,961; Birmingham 2,551; Phoenix 1,765 |
| Moderate | 4,500 | 3,500 to 5,500 | St. Louis 4,900; Kansas City 4,711; Baltimore 4,654; Washington 4,224 |
| Cold | 6,500 | 5,500 to 7,500 | Chicago 5,882 to 6,639; Boston 5,634; Detroit 6,232; Denver 5,524 to 6,283 |
| Very cold | 8,500 | 7,500 to 9,500 | Minneapolis 8,382; Bismarck 8,851; Sault Ste. Marie 9,048 |
| Extreme | 10,500 | Over 9,500 | Duluth 10,000; Anchorage 10,864; Fairbanks 14,279 |
If your city sits near a zone boundary, or you want a sharper number, enter your own heating degree days. NOAA publishes annual degree-day normals for United States stations, and the Climate Prediction Center publishes current degree-day statistics by city. Concord, New Hampshire, for example, has 7,383 heating degree days in the ICC table. A 1,500 square foot home there with average insulation needs 1,500 times 7,383 times 8, which is 88.60 million BTU, and at 19.20 million BTU per cord of red oak in a stove, that is 88.60 divided by 19.20, which is 4.61 cords. UNH Extension estimates 4 to 5 cords for a fairly weather-tight 1,500 square foot New Hampshire home, so the calculator lands inside the published range.
The heat-loss factors are the tool's own calibration, and they are the one part of the formula no single table publishes. The three levels are 6 BTU per square foot per heating degree day for a well-insulated home, 8 for an average home, and 12 for a drafty or older home. They were set so the calculator reproduces the published extension estimates: UNH Extension, 4 to 5 cords for a fairly weather-tight 1,500 square foot New Hampshire home; West Virginia University Extension, about 4 cords for a 1,500 square foot home; Oklahoma State University Extension, 1 to 2 cords per 1,000 square feet; Montana State University Extension, 2 to 4 cords for a medium-sized modern home heated entirely with wood; and the Chimney Safety Institute of America, 3 to 6 cords a season for primary heat, 2 to 3 cords per 1,000 square feet in northern climates, and 1 to 2 cords per 1,000 square feet in milder ones.
Check the calibration against the anchors. A 1,500 square foot home in a Cold climate with average insulation needs 4.06 cords of red oak in a modern stove, inside the UNH and West Virginia ranges. The same home in a Mild climate needs 1.56 cords, inside the Oklahoma State range of 1.5 to 3 cords for 1,500 square feet. A well-insulated 1,500 square foot home in a Cold climate needs 1,500 times 6,500 times 6 divided by one million, which is 58.50 million BTU, and at 19.20 million BTU per cord that is 3.05 cords, inside the Montana State range of 2 to 4 cords for a medium-sized modern home. A drafty 2,000 square foot home in a Cold climate needs 2,000 times 6,500 times 12, which is 156.00 million BTU, and at 19.20 million BTU per cord that is 8.13 cords. The calibration is honest about what it is: a planning estimate anchored to published figures, not a measurement of your house. Your own burn record over one winter beats any calculator.
The second part of the formula is the usable heat per cord. Usable heat per cord equals the heat value of the species times the appliance efficiency. For red oak in a modern stove, it is 24.0 times 80%, which is 19.20 million BTU. For red oak in an open fireplace, it is 24.0 times 15%, which is 3.60 million BTU. The species values come from Penn State Extension Table 1, printed in full below. The efficiency figures come from three sources, and the calculator states each one: Penn State Extension puts an open fireplace at 10 to 20% efficient and a modern wood stove at 80% or more, so the calculator uses the 15% midpoint for the fireplace and the 80% floor for the stove; the University of Maryland Extension Fact Sheet FS-939 puts an EPA-certified fireplace insert at 55 to 75%, so the calculator uses the 65% midpoint; and the USDA Forest Service puts high-efficiency cordwood energy systems at about 70 to 80%, so the calculator uses the 75% midpoint for a wood furnace.
Two of those figures carry a note. The University of Maryland Extension range for a conventional fireplace is lower than Penn State's, at minus 10 to 10%, because it counts the warm room air a fireplace draws up the chimney: a fireplace can pull more heat out of a house than it puts in. Penn State governs in this calculator for consistency with the companion Firewood BTU Calculator, which uses the same table and the same figures, and the content states both ranges so you can judge. The stove figure of 80% is the floor of Penn State's "80% or more", and the EPA's own averages are 78% for catalytic stoves and 71% for non-catalytic stoves, so a good stove may do better than 80% and an older one will do worse. If you know your appliance rating, enter it: the custom efficiency option exists for exactly that reason.
The cords follow by division. Cords needed equal the heat the wood must supply, divided by the usable heat per cord. For the default case, 78.00 divided by 19.20 is 4.06 cords. The calculator then rounds up to whole cords, because firewood is sold by the cord and 4 cords would leave you short. When the division comes out whole, the calculator says so: a 1,500 square foot home with 4,800 heating degree days and average insulation needs 57.60 million BTU, and 57.60 divided by 19.20 is exactly 3 cords, so you buy exactly 3 cords.
The stacking figures follow from the cords you buy. A full cord is a stack 4 feet high, 8 feet long, and 4 feet deep, which is 128 cubic feet of stacked wood, including the air gaps between the splits. Five cords are 5 times 128, which is 640.0 cubic feet. Stacked 4 feet high with 16-inch logs, one cord runs 24 feet long, because 128 divided by 4 feet of height times 16 inches of depth is 24 feet. Five cords run 5 times 24, which is 120.0 feet, which is 15 rows 8 feet long, and the row covers 120.0 times 16 inches, which is 160.0 square feet of ground. A face cord of 16-inch pieces is one third of a full cord, so 4.06 cords is 4.06 times 3, which is 12.18 face cords.
The cost figures follow from the price you enter. Season cost equals cords to buy times price per cord: 5 cords at $250 a cord is $1,250.00. Cost per million BTU of delivered heat equals price per cord divided by usable heat per cord: $250 divided by 19.20 is $13.02. Cost per million BTU of gross heat equals price per cord divided by heat per cord: $250 divided by 24.0 is $10.42. The delivered figure is the one to compare between offers, because it is the price of the heat that reaches the room.
Every figure the calculator prints is computed from the rounded values shown on the page, so the printed equations reconcile. The wood share is computed from the rounded total load, the cords from the rounded wood share and the rounded usable heat per cord, and the gross heat from the rounded cords. Money rounds to the cent, heat rounds to two decimals in million BTU, cords round to two decimals, and percentages round to one decimal. The rounding rule is half-up, the same rule a hand calculation uses. The under-buy risk from rounding before the ceiling is at most 0.005 cords, about two thirds of a cubic foot, which is negligible against a cord.
The firewood heat table
The table below is the Penn State Extension table in full, from Heating with Wood: An Introduction, Table 1, by Hank Stelzer, 2017, re-checked against the Penn State Extension page on 21 November 2026. Values are million BTU per full cord of air-dried wood at an assumed moisture content of 20%. The table covers common hardwood of the Northeastern United States. The heat band is the calculator's own grouping: High is 24.0 million BTU per cord or more, Medium is 20.0 to under 24.0, and Low is under 20.0. Nine of the 16 species are High, five are Medium, and two are Low. The rank uses competition ranking, so tied species share a rank and the next rank skips: hornbeam and black birch share 4th place at 26.8 million BTU per cord, and the next species, honey locust, is 6th.
| Species | Million BTU per cord | Rank | Heat band | Cords for 78.00 million BTU in a stove |
|---|---|---|---|---|
| Osage orange | 30.7 | 1 | High | 3.18 |
| Hickory | 28.0 | 2 | High | 3.48 |
| Ironwood / hop hornbeam | 27.3 | 3 | High | 3.57 |
| Hornbeam / blue beech | 26.8 | 4 | High | 3.64 |
| Black birch | 26.8 | 4 | High | 3.64 |
| Honey locust | 26.7 | 6 | High | 3.65 |
| White oak group | 25.7 | 7 | High | 3.79 |
| Sugar maple | 24.0 | 8 | High | 4.06 |
| Red oak group | 24.0 | 8 | High | 4.06 |
| White ash | 23.6 | 10 | Medium | 4.13 |
| Yellow birch | 23.6 | 10 | Medium | 4.13 |
| Hackberry | 20.8 | 12 | Medium | 4.69 |
| Birch, paper, gray, and river | 20.3 | 13 | Medium | 4.80 |
| Black walnut | 20.2 | 14 | Medium | 4.83 |
| Black cherry | 19.9 | 15 | Low | 4.90 |
| Maple, red and silver | 18.7 | 16 | Low | 5.21 |
The last column shows the cords each species needs for the default home, 78.00 million BTU of delivered heat in a modern stove at 80% efficiency. The gap between the hottest and the lightest wood is 2.03 cords on the same home: Osage orange needs 3.18 cords and red and silver maple needs 5.21 cords. That is the species effect at its widest. In practice, most buyers choose between the common hardwoods, where the gap is smaller: white oak needs 3.79 cords, red oak 4.06, white ash 4.13, and black cherry 4.90. Penn State Extension warns that burning large amounts of very high heat wood like Osage orange or ironwood can burn through the bottom of some stoves, so mix the hottest wood with a milder species and keep the air control down.
Softwood is not in the Penn State table, which covers hardwood of the Northeastern United States. For pine, fir, spruce, or hemlock, use the custom species option with a published figure. The Virginia Tech table by Bond and Downing puts white pine at 14.3 and hemlock at 15.9 million BTU per cord, and the Nebraska Extension guide puts Douglas fir at 20.7. Penn State Extension advises limiting conifers in heating use, because their secondary compounds can coat a chimney with tar, soot, and creosote, which may lead to a chimney fire if the chimney is not cleaned regularly. Softwood seasons fast and lights easily, which makes it good kindling and good shoulder-season wood, but it takes far more cords to heat a house through a winter: at 14.3 million BTU per cord in a stove, the default home needs 78.00 divided by 11.44, which is 6.82 cords.
How many cords by home size and climate
The table below gives the cords for an average-insulation home heated entirely with red oak in a modern wood stove at 80% efficiency, which delivers 19.20 million BTU per cord. Read across for your home size and down for your climate. A drafty home needs 50% more than the table shows, a well-insulated home needs 25% less, and wood supplying half the heat needs half the table figure.
| Home size | Mild, 2,500 HDD | Moderate, 4,500 HDD | Cold, 6,500 HDD | Very cold, 8,500 HDD | Extreme, 10,500 HDD |
|---|---|---|---|---|---|
| 1,000 sq ft | 1.04 | 1.88 | 2.71 | 3.54 | 4.38 |
| 1,500 sq ft | 1.56 | 2.81 | 4.06 | 5.31 | 6.56 |
| 2,000 sq ft | 2.08 | 3.75 | 5.42 | 7.08 | 8.75 |
| 2,500 sq ft | 2.60 | 4.69 | 6.77 | 8.85 | 10.94 |
Read the table against the published rules of thumb. The Chimney Safety Institute of America quotes 2 to 3 cords per 1,000 square feet in northern climates and 1 to 2 cords per 1,000 square feet in milder ones. The table gives 2.71 cords per 1,000 square feet in a Cold climate and 1.04 in a Mild climate, both inside those bands. The typical range for primary heat, 3 to 6 cords a winter, covers a 1,500 square foot home from a Moderate climate at 2.81 cords to a Very cold climate at 5.31 cords, and a 2,000 square foot home from Moderate at 3.75 to Cold at 5.42. Homes outside the typical range are easy to spot: a 2,500 square foot home in an Extreme climate needs 10.94 cords, and a 1,000 square foot cabin in a Mild climate needs 1.04.
What changes the answer most
The four factors do not matter equally. Ranked by the size of the swing they cause on the default home, the appliance comes first, insulation second, climate third, and species last. Knowing the order saves money, because the biggest lever is usually the cheapest to pull.
The appliance is the biggest lever by far. The default home needs 4.06 cords with a modern stove at 80% efficiency. With an EPA-certified fireplace insert at 65%, each cord delivers 24.0 times 65%, which is 15.60 million BTU, and the home needs 78.00 divided by 15.60, which is exactly 5.00 cords. With a wood furnace at 75%, each cord delivers 18.00 million BTU, and the home needs 78.00 divided by 18.00, which is 4.33 cords. With an open fireplace at 15%, each cord delivers 3.60 million BTU, and the home needs 78.00 divided by 3.60, which is 21.67 cords. The fireplace needs more than five times as many cords as the stove for the same heat: 80 divided by 15 is 5.33. An insert in an existing fireplace is the single most effective upgrade a wood-burning household can make, and the EPA notes that a well-fitted insert can function nearly as efficiently as a wood stove.
Insulation is the second lever. The default home at average insulation needs 4.06 cords. Well insulated, it needs 3.05 cords. Drafty, it needs 6.09 cords: the load is 1,500 times 6,500 times 12, which is 117.00 million BTU, and 117.00 divided by 19.20 is 6.09 cords. The drafty home burns half as much wood again as the average home, and twice as much as the well-insulated one. Air sealing and insulation pay for themselves in cordwood saved, and they pay every winter, not just once.
Climate is the third lever, and it is the one you cannot change. The default home needs 1.56 cords in a Mild climate, 2.81 in Moderate, 4.06 in Cold, 5.31 in Very cold, and 6.56 in Extreme. Moving from Moderate to Very cold nearly doubles the wood. That is why firewood advice from another region misleads: a figure that is right for St. Louis is wrong for Minneapolis by almost a factor of two.
Species is the smallest lever, and the one buyers argue about most. On the default home, the gap between Osage orange at 3.18 cords and red and silver maple at 5.21 cords is 2.03 cords, and the gap between the common hardwoods is under a cord. Species matters for the price per cord, not for the cord count: a cord of Osage orange at $300 costs less per unit of heat than a cord of red oak at $250, because the Osage orange cord holds 30.7 million BTU and the red oak cord holds 24.0. At 80% efficiency, the Osage orange costs $300 divided by 24.56, which is $12.21 per million BTU of delivered heat, and the red oak costs $250 divided by 19.20, which is $13.02. The dearer cord is the cheaper heat.
Stacking and storing the wood
Buy the wood early and stack it right, and the cords you calculated are the cords you burn. Buy it late and stack it wrong, and you burn more wood for less heat. Firewood demand peaks in autumn, and the best time to cut is February or March, when the dry winter air helps the wood dry faster. Plan to cut and stack a year ahead, and keep a second year of wood in reserve in case a wet year delays seasoning.
Stack the wood off the ground on pallets or rails, in a single row with air on both sides, with the top covered and the sides open. A stack 4 feet high with 16-inch logs runs 24 feet per cord, so 5 cords need 120.0 feet of row, or 15 rows 8 feet long, covering 160.0 square feet of ground. Do not stack against the house wall: the stack holds moisture against the siding and gives insects a path indoors. Do not tarp the whole stack: the tarp traps moisture and the wood rots instead of drying.
Moisture is the hidden variable in every cord calculation. The heat table assumes seasoned wood at about 20% moisture. Freshly cut northern red oak can be 60 to 80% moisture, and wet wood holds far less usable heat: every pound of water in the wood has to be boiled off in the firebox, and each pound of steam carries about 1,210 BTU up the flue, according to the USDA Forest Products Laboratory. A moisture meter costs little and settles the question: split a piece and test the fresh face, not the dry outside. Wood at 20% moisture or less is ready to burn. Wood above 25% is not, and burning it wastes wood and coats the chimney with creosote.
Seasoning takes time, and the time depends on the species. Ash splits easily and dries fast, and it is the one hardwood that burns reasonably well even before it is fully seasoned. Oak is slow: white oak and red oak need 12 to 24 months to season properly. Hickory needs a year or more. Pine and other softwoods season in about 6 months. Split the wood before you stack it: a split piece dries from four faces, a round log dries from two ends, and the difference is a season.
Buying firewood: cords, face cords, and prices
A cord is a stack 4 feet high, 8 feet long, and 4 feet deep: 128 cubic feet of stacked wood, including the air gaps between the splits. It is the standard measure for firewood in the United States, and in most states it is the only legal measure for a sale: a seller who quotes a price per truckload or per pile is selling a measure you cannot check. Penn State Extension gives the measuring formula: multiply the height, width, and length of the pile in feet, then divide by 128. A stack 4 feet high, 8 feet wide, and 8 feet long is 4 times 8 times 8 divided by 128, which is 2 cords.
A face cord is a stack 4 feet high and 8 feet long with a shorter depth, generally 16 inches, though Penn State Extension notes it may run from 12 to 32 inches. A face cord of 16-inch pieces is one third of a full cord, so 3 face cords make a full cord, and 4.06 cords is 12.18 face cords. A face cord of 12-inch pieces is one quarter of a cord. Always ask the depth before you compare prices: a face cord at $100 with 16-inch pieces is $300 a cord, and the same face cord with 12-inch pieces is $400 a cord. If a seller will not state the depth, buy from someone who will.
Prices vary by region, species, season, and whether the wood is delivered, split, and stacked. Kiln-dried delivered wood costs more than air-dried, and split and delivered wood costs more than unsplit and picked up. The calculator takes no position on what a cord should cost: you enter your price, and it works out the season cost and the cost per million BTU. Compare offers on cost per million BTU of delivered heat, not on price per cord. A cord of hickory at $300 in a stove costs $300 divided by 22.40, which is $13.39 per million BTU of delivered heat. A cord of red and silver maple at $200 costs $200 divided by 14.96, which is $13.37. The two offers are the same price for the same heat, even though one cord costs half as much again as the other.
One cord of seasoned northern red oak produces the same amount of heat as 159 gallons of fuel oil, according to Penn State Extension. The default home burns 4.06 cords, which is about 4.06 times 159, which is about 646 gallons of oil equivalent in gross heat terms. That comparison is a rough guide only: it compares gross heat in the wood with gross heat in the oil, before either appliance takes its share, and a modern oil furnace is far more efficient than an open fireplace.
Use cases
Heating a whole house with wood for the first time. Start with the default case for your home size and climate, then buy the cords it suggests and track what you actually burn. Your first winter is a measurement exercise: note the date the stack starts and the date it runs out, and next year you will know your home's real number. If the calculator says 5 cords and you burned 6, your home is draftier than average or your wood was wetter than 20% moisture, and you can adjust the insulation setting next year. Do not buy exactly the calculated figure in your first year: buy the rounded-up figure, and keep a spare face cord or two. Running out in February costs more than a cord left over in spring.
Wood as supplemental heat. Many homes run a stove in the main living area and let the furnace cover the rest, or burn wood on cold evenings and weekends only. Pick the share wood supplies: half the heat halves the cords. A 1,500 square foot home in a Cold climate with average insulation needs 4.06 cords for full wood heat and 2.03 cords at half the heat: the wood share is 78.00 times 50%, which is 39.00 million BTU, and 39.00 divided by 19.20 is 2.03 cords. At a quarter of the heat, the same home needs 1.02 cords: 78.00 times 25% is 19.50 million BTU, and 19.50 divided by 19.20 is 1.02 cords. The EPA notes that zone heating with a certified wood stove can cut the overall heating bill substantially compared with a furnace alone, because the stove heats the room you live in and the furnace runs less.
A cabin or a small home. Small spaces need little wood, and the calculator says so honestly: a 500 square foot cabin in a Mild climate, well insulated, with occasional fires, needs 0.08 cords of Osage orange in a modern stove. The heat load is 500 times 2,500 times 6, which is 7.50 million BTU, wood supplies 25% of it, which is 1.88 million BTU, and each cord of Osage orange in a stove delivers 24.56 million BTU, so the cords are 1.88 divided by 24.56, which is 0.08. Buy 1 cord and it will last more than one winter. The same cabin with a fireplace instead of a stove needs 0.41 cords: each cord of Osage orange in a fireplace delivers 4.61 million BTU, and 1.88 divided by 4.61 is 0.41 cords.
Upgrading from a fireplace to an insert. An EPA-certified insert turns a decorative fireplace into a real heater. On the default home, the fireplace needs 21.67 cords and the insert needs exactly 5.00 cords, so the insert saves 16.67 cords a winter. At $250 a cord, that is $4,167.50 a winter in wood saved, which pays for the insert in one or two seasons. The insert needs a chimney liner and a certified installer, and it uses electricity for a fan, so it will not heat during a power outage the way a freestanding stove does. Check the model against the EPA certified list before you buy.
A wood furnace heating the whole house through ducts. A forced-air wood furnace heats an entire residence through ductwork, like a fossil-fuel furnace, and the EPA classes large forced-air furnaces as capable of 65,000 BTU per hour or more. On the default home, the furnace at 75% efficiency needs 4.33 cords, between the stove at 4.06 and the insert at 5.00. Furnaces need regular loading and ash removal, and the wood must be cut to the firebox length, but they heat rooms a stove cannot reach. If your furnace has a rating plate efficiency, enter it as a custom figure: the 75% default is the midpoint of the USDA Forest Service range, and your model may run higher or lower.
Ordering wood for a woodlot or a farm. If you cut your own wood, the calculator tells you how many trees to plan for. One acre of average eastern woodland grows about 0.5 to 1 cord of wood per year sustainably, so a 10-acre woodlot supports a 5 to 8 cord house when managed. A 5-cord house needs 5 acres at the low end of growth, and cutting more than the growth each year runs the woodlot down. The Nebraska Extension cutter's rule of thumb gives trees per cord by diameter: a 10-inch tree yields about 4 to 6 trees per cord, and a 16-inch tree yields about 2 trees per cord. Plan the cut a year ahead so the wood seasons before you burn it.
Sources
Every figure in this calculator comes from a published source, re-checked on 21 November 2026 unless noted. The heat table, the cord definition, the face cord definition, the fireplace and stove efficiencies, the pellet stove efficiency, the oil equivalence, and the moisture figures come from Penn State Extension, Heating with Wood: An Introduction, Table 1 (Hank Stelzer, 2017). The insert efficiency range and the conventional fireplace range come from University of Maryland Extension Fact Sheet FS-939, Buying a Clean Burning Wood Stove, updated 6 January 2021. The furnace efficiency range comes from the USDA Forest Service, Wood Energy in Alaska (Miles, 2006), which puts high-efficiency cordwood energy systems at about 70 to 80%. The stove efficiency averages, 78% for catalytic stoves and 71% for non-catalytic stoves, and the appliance descriptions come from the US EPA Burn Wise frequent questions and the US EPA choosing wood-burning appliances pages. The heating degree-day city figures come from the Engineering Toolbox United States heating degree-day table and the ICC Appendix D degree-day table, and the degree-day definition and normals come from NOAA, Annual Degree Days to Selected Bases, 1971-2000. The softwood heat values, white pine 14.3 and hemlock 15.9 million BTU per cord, come from Virginia Tech, Firewood Facts, Follies and Forest Management (Bond and Downing). The calibration anchors come from the extension estimates summarized in the Farmers Almanac regional firewood guide (UNH Extension, West Virginia University Extension, Iowa State University Extension, Oklahoma State University Extension, Montana State University Extension) and the Family Handyman guide quoting the Chimney Safety Institute of America. The heating-degree-day formula and the woodlot growth figures come from The Outpost, Wood Heat. The steam heat figure, about 1,210 BTU per pound of steam up the flue, comes from the USDA Forest Service, Forest Products Laboratory, Wood Fuel Combustion Practice (Reineke, Report R1666-18, 1947, reaffirmed 1956). The Douglas fir figure of 20.7 million BTU per cord and the trees-per-cord rule of thumb come from the Nebraska Extension NebGuide G1554, Heating with Wood.
For the heat in the cords you already have, use our Firewood BTU Calculator, which shares the same Penn State Extension table and works out total BTU, usable heat, and cords for a heat target. For the lumber in a log before you cut it for firewood, use our Log Board Foot Calculator. To measure a tree before you fell it, use our Tree Height Calculator, and to see what a tree is worth standing, use our Tree Benefits Calculator. To size electric heat for the rooms wood does not reach, use our Mini-Split BTU Sizer.
Frequently asked questions
How many cords of firewood do I need for a 1,500 sq ft house?
A 1,500 square foot house with average insulation, heated entirely with red oak in a modern wood stove, needs 1.56 cords in a Mild climate, 2.81 cords in a Moderate climate, 4.06 cords in a Cold climate, 5.31 cords in a Very cold climate, and 6.56 cords in an Extreme climate. The Cold climate figure of 4.06 cords means you buy 5 cords, and it matches the UNH Extension estimate of 4 to 5 cords for a fairly weather-tight 1,500 square foot New Hampshire home. A drafty house needs 50% more, a well-insulated house needs 25% less, and wood supplying half the heat needs half the figure.
What is a cord of firewood?
A cord is a stack of wood 4 feet high, 8 feet long, and 4 feet deep, which is 128 cubic feet of stacked wood, including the air gaps between the splits. To measure a stack, multiply the height, width, and length in feet, then divide by 128: a stack 4 feet high, 8 feet wide, and 8 feet long is 4 times 8 times 8 divided by 128, which is 2 cords. A face cord is a stack 4 feet high and 8 feet long with a shorter depth, generally 16 inches, and it holds one third of a full cord, so 3 face cords make a full cord. A face cord of 12-inch pieces holds one quarter of a cord.
How many cords of firewood do I need per 1,000 square feet?
The Chimney Safety Institute of America quotes 2 to 3 cords per 1,000 square feet in northern climates and 1 to 2 cords per 1,000 square feet in milder ones, for primary heat with a reasonably efficient stove. This calculator gives 2.71 cords per 1,000 square feet in a Cold climate with average insulation and red oak in a modern stove, and 1.04 cords per 1,000 square feet in a Mild climate, both inside those bands. A drafty home in a Cold climate needs 4.06 cords per 1,000 square feet, and a well-insulated home in a Cold climate needs 2.03 cords per 1,000 square feet.
Which firewood needs the fewest cords for the same heat?
Osage orange needs the fewest cords: at 30.7 million BTU per cord, it heats the default 1,500 square foot Cold-climate home on 3.18 cords, against 4.06 cords of red oak and 5.21 cords of red and silver maple. Hickory is next at 3.48 cords, then ironwood at 3.57, hornbeam and black birch at 3.64 each, and white oak at 3.79. Penn State Extension warns that burning large amounts of very high heat wood like Osage orange or ironwood can burn through the bottom of some stoves, so mix the hottest wood with a milder species.
Does the stove or fireplace change how many cords I need?
Yes, more than any other factor. The default 1,500 square foot Cold-climate home needs 4.06 cords with a modern wood stove at 80% efficiency, 4.33 cords with a wood furnace at 75%, exactly 5.00 cords with an EPA-certified fireplace insert at 65%, and 21.67 cords with an open fireplace at 15%. The fireplace needs more than five times as many cords as the stove for the same heat, because 80 divided by 15 is 5.33. An insert in an existing fireplace is the single most effective upgrade a wood-burning household can make.
What are heating degree days and how do I find mine?
Heating degree days measure how cold a climate is over a full year, on a base of 65 degrees Fahrenheit. For each day the average temperature falls below 65, the difference is added to the yearly total: a day averaging 35 degrees adds 30. NOAA publishes annual degree-day normals for United States stations, and the Climate Prediction Center publishes current degree-day statistics by city. Concord, New Hampshire, has 7,383 heating degree days: a 1,500 square foot home there with average insulation needs 88.60 million BTU, which is 4.61 cords of red oak in a modern stove. Enter your own figure in the optional box and the calculator uses it instead of the zone figure.
How much does it cost to heat with firewood for a winter?
It depends on your cords and your price per cord. The default 1,500 square foot Cold-climate home needs 4.06 cords of red oak, so you buy 5 cords, and at $250 a cord the season costs $1,250.00, which is $13.02 per million BTU of delivered heat. Dearer wood can cost less per unit of heat: 4 cords of Osage orange at $300 a cord cost $1,200.00 for the season and $12.21 per million BTU of delivered heat, because each Osage orange cord holds 30.7 million BTU against 24.0 for red oak. Compare offers on cost per million BTU of delivered heat, not on price per cord.
How much space do I need to stack the wood?
A full cord is 128 cubic feet of stacked wood. Five cords are 640.0 cubic feet. Stacked 4 feet high with 16-inch logs, one cord runs 24 feet long, so 5 cords run 120.0 feet, which is 15 rows 8 feet long, covering 160.0 square feet of ground. Ten cords double all of it: 1,280.0 cubic feet, 240.0 feet of row, 30 rows 8 feet long, and 320.0 square feet of ground. Five cords equal 15 face cords of 16-inch pieces. Stack the wood off the ground on pallets or rails, in a single row with air on both sides, with the top covered and the sides open.