What Size Tankless Water Heater Do I Need?

Fixtures running at the same time

Count only the fixtures that really run together at your busiest moment, not every fixture in the house. Flow rates are the average figures ENERGY STAR lists for sizing a tankless unit, except the low-flow shower, which uses the EPA WaterSense limit of 2.0 gallons per minute.

Other fixtures (optional)

Use these rows for any fixture whose flow you know from its label or manual, or for a tub filler, which Rinnai puts at about 4 gallons per minute. Enter a flow between 0.1 and 10 gallons per minute.

Incoming water temperature

Use the coldest water of the year, because that sets the size. The Department of Energy says to assume 50 degrees unless you know otherwise, and to heat to 120 degrees for most uses. Zone temperatures are bands from the Rinnai groundwater map, which runs from 35 to 77 degrees across the United States.

Estimated recommended size

This tool provides estimates for general guidance only. Flow rates and groundwater temperatures vary by fixture, home and season, so confirm the size against the manufacturer's flow-at-rise table before buying. Always check the manufacturer's specifications before buying.
Quick answer: Most homes need a tankless unit that delivers 3 to 5 gallons per minute at a 60 to 70 degree temperature rise, which takes roughly 90,000 to 175,000 BTU per hour of heat. Add up the flow of the fixtures you run at the same time, subtract your incoming water temperature from 120 degrees, and multiply flow by rise by 500 to get the heat you need. Gas units cover whole-house loads far more easily than electric ones: at a 70 degree rise, the Department of Energy notes gas units typically manage about 5 gallons per minute while electric units manage about 2.

Last reviewed: 19 November 2026. Reviewed every 180 days; next review due 18 May 2027.

How to use the Tankless Water Heater Size Calculator

A tankless water heater has no tank to run down, so it is sized completely differently from a storage heater. What matters is how much hot water you draw at the same moment, and how far the heater has to lift the temperature of the water coming in. Get either number wrong and the unit runs lukewarm at the worst moment of the day. This calculator follows the sizing method published by the U.S. Department of Energy: add up the flow of the fixtures you run at the same time, find the temperature rise from your incoming water to the temperature you want, and convert the two into the heat the unit must deliver. It takes less than a minute.

  1. Count the fixtures that run at the same time. Work through the list: standard showers, low-flow showers, bathroom faucets, kitchen faucets, dishwasher, washing machine, bathtub. Count only what really runs together at your busiest moment, not every fixture in the house. A shower plus a kitchen faucet is the common real peak for a couple; two showers plus a faucet is the common peak for a family. The flow rate printed under each fixture is the average figure ENERGY STAR lists for sizing a tankless unit, except the low-flow shower, which uses the EPA WaterSense limit of 2.0 gallons per minute.
  2. Add other fixtures if you know their flow. Use the two custom rows for anything whose flow you know from its label or manual. The usual case is a tub filler: Rinnai puts filling a tub at about 4 gallons per minute, because tub spouts are not flow restricted, so a fast tub filler deserves its own row rather than the 2.5 gallon per minute bathtub row.
  3. Set the incoming water temperature. Pick your climate zone and the temperature fills in, or type your own figure. Use the coldest water of the year, because that sets the size. The Department of Energy says to assume 50 degrees unless you know otherwise. Zone temperatures are bands from the Rinnai groundwater map, which runs from 35 to 77 degrees across the United States.
  4. Set the desired hot water temperature. The default is 120 degrees, the figure the Department of Energy uses for most purposes. You can raise it to 140 degrees if you have a dishwasher without an internal heater, but that sharply increases the size of unit you need, as the worked example below shows.
  5. Read your result. You get your required flow rate in gallons per minute, your required temperature rise, the heat you need in BTU per hour and in kilowatts, the gas input a condensing unit and a non-condensing unit would each need, the smallest common gas size and the smallest common electric size that cover the load, the flow each recommended unit delivers at your rise, and plain-language notes on gas lines, venting, breakers and service panels.

This calculator is one of the free tools on Tools Elite. Every figure on this page comes from a published source listed at the bottom, and the calculator shows its work: the flow total, the rise, and the heat figure are all in the result. Sizing is an estimate, not a design for a particular home, so treat the recommendation as a starting point and check the manufacturer's flow-at-rise table before you buy. If you are sizing several systems for the same home, the same approach applies to cooling and air cleaning: see the Mini Split BTU Sizer and the Air Purifier Size Calculator.

How it works

The calculator follows the Department of Energy's sizing method for demand-type water heaters, in three steps: add up the flow, find the temperature rise, and convert the two into heat.

Step 1: add up the flow. Tankless or demand-type water heaters are rated by the maximum temperature rise possible at a given flow rate, the Department of Energy says, so sizing starts by listing the hot water devices you expect to use at any one time and adding up their flow rates in gallons per minute. The flow rates in this calculator are the average figures ENERGY STAR lists for sizing a whole-home gas tankless unit: shower and bathtub 2.5 gallons per minute, clothes washer 3.3, kitchen and bathroom sink 2.2, dishwasher 1.3. The low-flow shower option uses the EPA WaterSense limit of 2.0 gallons per minute; the federal maximum for a showerhead is 2.5 gallons per minute, and WaterSense-labeled bathroom faucets use no more than 1.5 gallons per minute against a standard 2.2.

Step 2: find the temperature rise. Temperature rise is the desired output temperature minus the incoming water temperature. The Department of Energy says to assume incoming water is 50 degrees unless you know otherwise, and to heat to 120 degrees for most uses, which gives a 70 degree rise. Incoming water varies far more than most buyers expect: the EPA puts average shallow groundwater temperatures in the United States at 5 to 25 degrees C, about 41 to 77 degrees F, and the Rinnai groundwater map shows bands from 35 degrees in the far north to 77 degrees in the south, with Hawaii and Puerto Rico at 75 degrees. Size on the coldest water of the year, not the average: Rinnai's own sizing guide warns that this is where even experienced installers make mistakes.

Step 3: convert flow and rise into heat. The formula is: required heat in BTU per hour equals flow in gallons per minute times temperature rise in degrees F times 500. The 500 comes from the weight of water: one gallon weighs about 8.33 pounds, one BTU heats one pound of water by one degree F, and there are 60 minutes in an hour, so 8.33 times 60 is about 500. To get kilowatts instead, divide BTU per hour by 3,412, the number of BTU in one kilowatt-hour. A gas unit's input rating must be higher than the heat figure, because no burner turns all of its fuel into hot water: this calculator divides by 0.95 for a condensing unit, the minimum Uniform Energy Factor for an ENERGY STAR certified gas tankless unit, and by 0.82 for a non-condensing one. Electric units turn nearly all of their input into heat, so the kilowatt figure is used directly.

Worked example, the Department of Energy's own. The Department of Energy's sizing page works this example: a hot water faucet at 0.75 gallons per minute and a shower head at 2.5 gallons per minute running at the same time need a flow of 3.25 gallons per minute. With incoming water at 50 degrees heated to 120 degrees, the rise is 70 degrees. The heat is 3.25 times 70 times 500, which is 113,750 BTU per hour, or about 33.3 kilowatts. A condensing gas unit needs about 119,800 BTU per hour of input for that heat, so the smallest common gas size is 130,000 BTU per hour. An electric unit needs 33.3 kilowatts, so the smallest common electric size is 36 kilowatts. Try it in the calculator: one standard shower plus a custom fixture at 0.75 gallons per minute, 50 degrees in, 120 degrees out.

Worked example, two showers and a kitchen faucet. Two standard showers at 2.5 gallons per minute each plus a kitchen faucet at 2.2 gallons per minute come to 7.2 gallons per minute. At a 70 degree rise the heat is 7.2 times 70 times 500, which is 252,000 BTU per hour, or about 73.9 kilowatts. A condensing gas unit would need about 265,300 BTU per hour of input, which is above the largest residential gas unit at 199,000 BTU per hour, so no single unit covers this load. That is the honest answer the calculator gives for heavy simultaneous use, and it is why the Department of Energy says that even the largest gas-fired model cannot supply enough hot water for simultaneous, multiple uses in large households, and that taking a shower and running the dishwasher at the same time can stretch a tankless water heater to its limit.

Worked example, the 140 degree trap. The Department of Energy notes that dishwashers without internal heaters may want water heated to 140 degrees. From 50 degree incoming water that is a 90 degree rise, not 70. One shower at 2.5 gallons per minute then needs 2.5 times 90 times 500, which is 112,500 BTU per hour, against 87,500 at a 70 degree rise, and the electric answer jumps from 25.6 kilowatts to 33 kilowatts. Most modern dishwashers heat their own water, so check the appliance manual before sizing the whole house for 140 degrees.

What your result means

The flow rate and the rise are two separate tests. A unit must deliver your flow at your rise, not merely match one of the two numbers. Every tankless unit delivers less flow as the rise grows, because the burner or the elements can only add heat at a fixed rate. Rinnai's RXP 199, a 199,000 BTU per hour unit, delivers 5.5 gallons per minute at a 70 degree rise, half its 11 gallon per minute maximum. The calculator shows the flow each recommended unit delivers at your rise, so you can see the margin, and the number to check on any spec sheet is the flow at your rise, never the headline gallons per minute on the box.

The gas answer and the electric answer are very different sizes. Gas-fired tankless units produce higher flow rates than electric ones, the Department of Energy says, and the numbers show why. A 70 degree rise is typically possible at about 5 gallons per minute through gas-fired units but only about 2 gallons per minute through electric ones, per the Department of Energy's sizing page. A single standard shower at a 70 degree rise needs 87,500 BTU per hour of heat, which is a 130,000 BTU per hour gas unit or a 27 kilowatt electric unit drawing 112.5 amps. Two showers at the same rise need a 199,000 BTU per hour gas unit, and no single electric unit covers them at all.

The electric answer comes with an electrical bill, not just a unit. Whole-house electric tankless units split their load across two to four 240 volt circuits, each on its own 40 or 50 amp double-pole breaker. The Rheem 18 kilowatt RTEX-18, the best-selling water heater on Amazon in the Water Heaters category per Tools Elite's Amazon category analysis of November 2026, draws 75 amps, needs two 40 amp double-pole breakers, and Rheem recommends at least a 150 amp service panel for it, noting that a panel upgrade is often needed when switching from an electric tank. The 36 kilowatt unit draws 150 amps across four 40 amp breakers and needs a 300 amp panel. If your panel cannot carry the unit, the panel upgrade is part of the real cost, and an electrician should confirm it before you buy.

The gas answer comes with gas line and venting work. A tankless burner fires at 130,000 to 199,000 BTU per hour, and the gas line that fed a storage tank is often too small for it. ENERGY STAR advises having a plumber confirm the gas line is big enough, and the Department of Energy advises having a qualified plumbing and heating contractor install the unit, because installation depends on fuel type, climate, local building code and safety issues around combustion. Condensing models vent through PVC pipe and need a condensate drain; the calculator flags both in its notes.

If the result says no single unit covers your load, that is a real answer. The realistic options are to stagger the heavy uses, for example running the washing machine when nobody is showering, to install two units, or to add a small point-of-use unit for a remote bathroom. The Department of Energy notes that installing a demand water heater at each hot water outlet can save even more energy than one whole-house unit. A plumber can confirm which option fits your home. Do not solve it by buying the biggest unit and hoping: above 199,000 BTU per hour input there is no residential gas unit to buy, because the federal definition of a gas-fired instantaneous water heater caps input below 200,000 BTU per hour.

Both fuels need electricity. Gas tankless units need electricity for ignition, the control board, safety sensors and the blower motor, even though gas heats the water, so neither fuel works in a power outage without backup power. If outages matter to you, our Home Generator Size Calculator sizes a generator for the loads you want to keep running.

Tankless water heater sizes explained

The tables below are the ladders this calculator uses. Gas sizes are input ratings in BTU per hour from Rinnai's RU series of condensing units; electric sizes are kilowatts from Rheem's RTEX series and the matching Eemax electrical table. Every figure is the manufacturer's own published number.

Gas size (input)Maximum flowUEFTypical use
130,000 BTU/hr6.6 GPM0.91One shower, or one shower plus a faucet, in a warm or moderate climate
160,000 BTU/hr8.0 GPM0.93One shower plus a faucet, or two low-flow showers, at a moderate rise
180,000 BTU/hr9.0 GPM0.93Two showers, or one shower plus a kitchen faucet, at a 70 degree rise
199,000 BTU/hr9.8 GPM0.93Two showers at a 70 degree rise; the largest residential gas unit

The maximum flows above are the headline figures, measured at a small temperature rise. At a 70 degree rise the 199,000 BTU per hour unit delivers about 5.4 gallons per minute, and Rinnai's own RXP 199 publishes 5.5 gallons per minute at a 70 degree rise. ENERGY STAR requires a certified gas tankless unit to deliver at least 2.8 gallons per minute over a 67 degree rise, with a Uniform Energy Factor of at least 0.95. Rinnai's RU series carries a UEF of 0.93 on the 160,000 to 199,000 BTU per hour models and 0.91 on the 130,000 model, which is why this calculator uses 0.95 for condensing efficiency and shows the non-condensing figure separately: real units vary, and the spec sheet of the exact model has the last word.

Electric sizeAmps at 240 VBreakersService panel
8 kW331 x 40 ampCheck with an electrician
11 kW461 x 60 ampCheck with an electrician
13 kW541 x 60 ampCheck with an electrician
18 kW752 x 40 amp150 amp minimum
24 kW1003 x 40 amp200 amp minimum
27 kW112.53 x 40 amp200 amp minimum
36 kW1504 x 40 amp300 amp minimum

Every breaker above is double-pole, one per circuit, and each circuit runs to its own terminal on the heater. Amps are watts divided by 240 volts. The panel figures are Rheem's recommendations for the RTEX series; no panel figure is published for the 8, 11 and 13 kilowatt sizes, so the calculator tells you to ask an electrician. Note how quickly the electrical demand grows: an 18 kilowatt unit alone draws more current than many whole homes used to draw, which is why the Department of Energy's 2 gallon per minute figure for electric units at a 70 degree rise is a practical limit, not just a rating.

Gas tanklessElectric tankless
Flow at a 70 degree riseAbout 5 GPM (DOE)About 2 GPM (DOE)
Largest common size199,000 BTU/hr input36 kW, about 122,800 BTU/hr of heat
Hookup the house needsGas line sized for the burner, venting, condensate drain on condensing modelsTwo to four 240 V circuits, 150 to 300 amp service panel
EfficiencyUEF 0.91 to 0.95 condensing; about 0.82 non-condensingUEF 0.94 on the Rheem RTEX-18; near all input becomes heat
Best forWhole-house use, cold climates, several fixtures at onceOne or two fixtures, warm climates, point-of-use spots

On energy use, the Department of Energy puts demand water heaters at 24 to 34 percent more energy efficient than conventional storage tanks for homes using 41 gallons or less of hot water a day, and 8 to 14 percent more efficient for homes using around 86 gallons a day. Most tankless units last more than 20 years, against 10 to 15 years for a storage tank. The saving comes from ending standby loss, the heat a tank bleeds through its walls while nobody is showering, so light-use homes gain the most in percentage terms and heavy-use homes gain the least.

Common mistakes to avoid

  • Buying on the headline GPM. The gallons per minute on the box is measured at a small temperature rise. A unit rated 11 gallons per minute may deliver 5.5 at a 70 degree rise. Size by the flow at your rise, from the manufacturer's flow-at-rise table.
  • Sizing on summer water. Groundwater is coldest in winter, and the rise in January can be 20 degrees larger than in July. Size on the coldest water of the year, as Rinnai's sizing guide advises, or the unit runs short exactly when you notice it most.
  • Counting every fixture in the house. Size for the fixtures that run at the same time, not for all of them. The Department of Energy's Building America guide makes the same point: a home may have a second and a third shower, but it is unlikely that all showers, the clothes washer and the dishwasher run at the same time. Count the realistic peak, and use the custom rows only for fixtures you know run together.
  • Forgetting the washing machine and dishwasher are intermittent. Both fill in short bursts, and many modern ones heat their own water or run cold cycles. If yours does, leave it out of the list. If you count a 3.3 gallon per minute washer that never draws hot water, you oversize by a whole unit class.
  • Assuming electric can do what gas does. At a 70 degree rise an electric unit typically manages about 2 gallons per minute against about 5 for gas, per the Department of Energy. A 27 kilowatt electric unit already needs 112.5 amps and three 40 amp breakers. Check the panel before falling in love with the unit.
  • Ignoring the minimum flow. Tankless units need a minimum flow to fire, 0.4 gallons per minute on the Rinnai RU series and 0.3 on the Rheem RTEX-18. A hand-washing trickle below that flow gets no hot water at all. The Building America guide warns that flow rates below 0.5 gallons per minute are common when washing hands or dishes, and not all units can deliver them.
  • Setting the temperature to 140 degrees without a reason. It raises the rise from 70 to 90 degrees from 50 degree water, which adds nearly 30 percent to the heat needed, and it raises the scald risk. Keep 120 degrees unless a dishwasher without an internal heater genuinely needs more.

Where sources disagree

Total flow against hot-water-only flow. This calculator sizes on total fixture flow, the flow the fixture delivers, which is the conservative approach and the one the Department of Energy's own worked example uses: a 2.5 gallon per minute shower head plus a 0.75 gallon per minute faucet. The Department of Energy's Building America guide sizes on hot-water-only flow instead: in its example a shower head rated at 2 gallons per minute draws only 1.5 gallons per minute of hot water at about 120 degrees, mixed with colder water to reach a comfortable temperature, and its sample home totals 4.5 gallons per minute of hot water from a shower, a clothes washer, a kitchen sink and a dishwasher. The hot-water figure is lower because the shower valve mixes cold water in. A unit that meets this calculator's total-flow number therefore has margin built in; a unit sized on hot-water-only flow is tighter and depends on the mixing assumption holding.

The washing machine: 3.3 against 2.0 gallons per minute. ENERGY STAR lists 3.3 gallons per minute as the average figure for a clothes washer, and this calculator uses it. The ASHRAE fill-rate range published by the Building America Solution Center runs from 1.0 to 6.0 gallons per minute, and other sizing guides use 2.0 as the typical figure inside that range. The difference is 1.3 gallons per minute, which at a 70 degree rise is 45,500 BTU per hour, enough to move the recommendation a full size class. Check your washer's manual: a front-loader on a cold cycle draws no hot water at all.

The bathtub: 2.5 against 4.0 gallons per minute. ENERGY STAR lists 2.5 gallons per minute for a shower and bathtub, and this calculator uses it for the bathtub row. Rinnai's sizing guide puts filling a tub at about 4 gallons per minute, and trade tables agree, because tub spouts are not flow restricted. If your tub fills fast, use a custom fixture row with 4 gallons per minute instead of the bathtub row.

Condensing efficiency: 0.93 against 0.95. This calculator divides by 0.95 for condensing gas input, the minimum Uniform Energy Factor for an ENERGY STAR certified gas tankless unit. Rinnai's RU series publishes a UEF of 0.93 on its 160,000 to 199,000 BTU per hour models and 0.91 on the 130,000 model, and some newer listings show 0.95 for the same units. The difference is small, about 2 percent on the input figure, and the ladder recommendation rarely changes. The spec sheet of the exact model has the last word, and the calculator shows the non-condensing input at 0.82 alongside so the range is visible.

The bathroom faucet: 2.2 against 1.5 gallons per minute. ENERGY STAR lists 2.2 gallons per minute for kitchen and bathroom sinks, the federal maximum, and this calculator uses it. WaterSense-labeled bathroom faucets use no more than 1.5 gallons per minute. If your faucets are WaterSense-labeled, the tool's figure is conservative by 0.7 gallons per minute per faucet, and the custom rows let you enter 1.5 exactly.

Frequently asked questions

What size tankless water heater do I need for 2 showers?

Two standard showers at 2.5 gallons per minute each need 5 gallons per minute, and at a 70 degree rise, from 50 degree incoming water to 120 degrees, that takes 175,000 BTU per hour of heat, or about 51.3 kW. A condensing gas unit needs about 184,300 BTU per hour of input for that heat, so the smallest common size that covers it is a 199,000 BTU per hour unit, which delivers about 5.4 gallons per minute at a 70 degree rise. No single electric unit covers two showers at a 70 degree rise: the largest common electric tankless is 36 kW, which makes about 122,800 BTU per hour. With low-flow showerheads at 2.0 gallons per minute each, the need drops to 4 gallons per minute, 140,000 BTU per hour, and a 160,000 BTU per hour gas unit covers it.

How many BTU do I need for a tankless water heater?

Multiply the gallons per minute you use at once by the temperature rise and by 500. One shower at 2.5 gallons per minute with a 70 degree rise needs 87,500 BTU per hour of heat; a shower plus a kitchen faucet at 4.7 gallons per minute needs 164,500 BTU per hour; two showers need 175,000 BTU per hour. A gas unit's input rating must be higher than the heat figure, because no burner is perfectly efficient: divide by 0.95 for a condensing unit or 0.82 for a non-condensing one. So one shower needs about 92,100 BTU per hour of gas input from a condensing unit, and two showers need about 184,300. Use the calculator above for your own fixtures and groundwater temperature.

Can an electric tankless water heater run a whole house?

Rarely, and only in a warm climate or a small home. The Department of Energy notes that a 70 degree rise is typically possible at about 2 gallons per minute through electric units, against about 5 gallons per minute through gas-fired ones. The largest common electric tankless is 36 kW, which makes about 122,800 BTU per hour of heat and draws 150 amps at 240 volts across four 40 amp breakers, with Rheem recommending at least a 300 amp service panel. A single standard shower at a 70 degree rise already needs 25.6 kW. Electric tankless suits one or two fixtures, a warm climate with a small rise, or a point-of-use installation. For a whole house in a cold climate, gas is the practical answer in most homes.

What size tankless water heater do I need for a family of 4?

It depends on how many fixtures run at the same time, not on the number of people. A family of four that runs two showers at once needs 5 gallons per minute, which at a 70 degree rise takes 175,000 BTU per hour of heat and a 199,000 BTU per hour gas unit. If the household staggers showers so only one runs at a time, with a faucet alongside, the need is about 4.7 gallons per minute, 164,500 BTU per hour, and a 180,000 BTU per hour gas unit covers it. Add a washing machine at 3.3 gallons per minute to two showers and the total passes what any single residential unit can do, which is why the calculator asks which fixtures really run together. Enter your own busiest moment above for the answer that fits your home.

Does a tankless water heater need a bigger gas line?

Often, yes. A tankless burner fires at 130,000 to 199,000 BTU per hour. ENERGY STAR advises having a plumber confirm the gas line is big enough, and the Department of Energy advises having a qualified plumbing and heating contractor install the unit, because installation depends on fuel type, climate, local building code and safety issues around combustion. The same contractor should confirm the venting: condensing models vent through PVC pipe. Get the gas line and the vent run checked before you buy the unit, not after.

What temperature should I set my tankless water heater to?

120 degrees F for most uses. That is the figure the Department of Energy uses in its sizing guidance, and it is hot enough for showers, sinks and laundry while keeping scald risk low. The Department of Energy notes one exception: dishwashers without internal heaters, and similar uses, may want 140 degree water, which raises the temperature rise to 90 degrees from 50 degree incoming water and sharply increases the size of unit you need. Most modern dishwashers heat their own water, so check the appliance manual before sizing for 140 degrees. Never set a unit above 140 degrees: Rinnai caps its units at 140 degrees even with a parameter adjustment.

Why does my tankless water heater run cold in winter?

Because the incoming water is colder, so the temperature rise is bigger and the unit's flow drops. Rinnai's RXP 199 delivers 5.5 gallons per minute at a 70 degree rise, half its 11 gallon per minute maximum, and groundwater in the far north sits at 35 to 42 degrees on the Rinnai map, pushing the rise past 80 degrees. The Department of Energy's sizing method uses the coldest water of the year for exactly this reason, and Rinnai advises sizing on the coldest groundwater temperature of the year, not summer temperatures. If the unit was sized on summer water, it runs short in January. The fix is to check the unit's flow-at-rise table against your winter rise, and to stagger the heavy uses, for example running the washer when nobody is showering.