UPS Runtime Calculator: How Long Will It Run?

The VA trap: a 1,500 VA UPS is not a 1,500 W UPS

UPS units are sold in volt-amperes (VA), but your gear draws watts. A typical home UPS delivers only about 0.6 W per VA, so a 1,500 VA unit usually delivers 900 W. Size by watts, not VA, or the UPS will overload the first time the power goes out.

1What plugs into the UPS?

Tap plus or minus to add each device. The wattage shown is a typical figure from published wattage tables; check your device label for the exact number, and use the custom rows below for anything not listed.

Or enter watts directly
W W W

Read watts from the label on the device or its power brick, or multiply volts by amps. Leave blank if you do not need a row.

Total load 0 W
2Your UPS

The VA number on the box, for example 1500.

Watts equal VA times power factor. Most home units are 0.6; check the spec sheet, which prints both numbers.

3Compare sizes (pick two or three)

The comparison shows load percentage, estimated runtime, and a verdict for each size at your load and power factor.

Estimated runtime

Load80% guideline

Compare sizes side by side

This tool provides estimates for general guidance only. Runtime is estimated from APC's published runtime chart and reduced 15% for a battery in typical condition, so real runtime varies with battery age, temperature, and load type. Always check the manufacturer's specifications before buying.
Quick answer: A 1,500 VA UPS at the typical 0.6 power factor delivers 900 W, not 1,500 W, and runs about 3 minutes at full load, about 11 minutes at half load, and about an hour at a 100 W load. Size by watts: add up your load, multiply by 1.25 for headroom, and keep the load at or below 80% of the watt rating. Enter your devices above to get your load, your runtime, and a side-by-side comparison of sizes.

Last reviewed: 20 November 2026. Reviewed every 180 days; next review due 19 May 2027.

How to use the UPS Runtime and Size Calculator

A UPS runtime calculator answers two questions at once: how big a UPS do you need, and how long will it keep your gear running when the power goes out? The two questions are linked, because runtime depends on the load as a percentage of the UPS watt rating, not on the VA number on the box. A 1,500 VA unit that delivers 900 W runs about 3 minutes at full load, about 11 minutes at half load, and about an hour at a 100 W load. This calculator adds up your load, converts your UPS rating to real watts, checks it against the 80% guideline, estimates runtime from APC's published runtime chart, and compares two or three sizes side by side so you can see what a bigger unit actually buys you. It takes less than a minute.

  1. Build your load list. Tap the plus button beside each device you plan to plug into the battery outlets: desktop PC, gaming PC, laptop, monitor, router, modem, NAS, switch, external drive, inkjet printer, TV, game console, or phone charger. Each device carries a typical wattage from published wattage tables, and the total updates as you tap. For a fast start, use one of the preset buttons: Home office loads a desktop, a monitor, a router, a modem, and a phone charger; Gaming desk loads a gaming PC with two monitors and a router; Network closet loads a router, a modem, a NAS, a switch, and an external drive.
  2. Enter watts directly for anything not listed. Use the three custom rows for devices the list does not cover, or for your own exact figures. Read watts from the label on the device or its power brick, or multiply volts by amps. A plug-in power meter gives the most honest number of all, because it measures what the device actually draws while you use it, and that number is often far below the rating on the power supply.
  3. Enter your UPS rating and power factor. Type the VA number from the box, for example 1500, and pick the power factor. Most home UPS units are 0.6, which is the default; most online double-conversion units are 0.9, and unity power factor units are 1.0. The spec sheet prints both the VA and the watt rating, so check it if you are unsure: watts equal VA times power factor, and that watt figure is the real limit on what the UPS can carry.
  4. Pick two or three sizes to compare. The comparison chips default to 1,000, 1,500, and 2,200 VA. Tap any chip to add or remove a size, up to three. The comparison table shows each size's watt rating, your load as a percentage of it, the estimated runtime, and a verdict, so you can see exactly what stepping up buys you in minutes.
  5. Read your result. The big number is the estimated runtime. Below it, the load bar shows your load as a percentage of the watt rating with the 80% guideline marked, and the list gives the total load, the real watt capacity, the VA you need with 25% headroom, and the smallest standard size that covers it. Read any warning before you buy: an overload warning means the UPS will shut down on battery the moment the power goes out.

This calculator is one of the free tools on Tools Elite. Every figure on this page comes from a published source listed at the bottom: APC and Schneider Electric for the sizing rules, the runtime chart, and the battery guidance; CyberPower for the 125% sizing rule; and published wattage tables for the device presets. If your outages run longer than any UPS can cover, our Home Generator Size Calculator sizes a generator for the same load list. If you only need to keep a phone alive through a blackout, the Power Bank Capacity Planner is the cheaper answer. The calculator gives estimates for general guidance, not a guarantee for any one model, so always check the manufacturer's specifications for the UPS you buy.

How it works

The calculator works in five steps: it adds up your load, it converts the UPS rating from VA to watts, it works out the size you need with headroom, it checks your load against the 80% guideline, and it estimates runtime from APC's published runtime chart.

Step 1: add up the load. Every device on the list carries a typical wattage taken from published wattage tables. A desktop PC in office use is 150 W, inside the 60 to 250 W range Anker SOLIX publishes for office desktops. A gaming desktop is 400 W, inside the 300 to 500 W range in published charts. A laptop is 60 W, a monitor is 25 W, a router and a modem are 10 W each, a NAS is 40 W, a network switch is 15 W, an external drive is 10 W, an inkjet printer is 40 W, a 55 inch LED TV is 100 W, a game console is 200 W, and a phone charger is 10 W. The calculator multiplies each preset by its quantity and adds any watts you entered directly. The total is your load in watts, and every later step works from it.

Step 2: convert VA to watts. Watts equal VA times power factor. A 1,500 VA UPS at the typical home power factor of 0.6 delivers 900 W; the same 1,500 VA at 0.9 delivers 1,350 W. Schneider Electric puts the power factor of most equipment at typically 0.6 to 0.9, and its worked example is 500 W divided by 0.8, which is 625 VA minimum. The calculator shows this conversion in plain language with every result, because it is the single most common sizing mistake: buyers read 1,500 VA and assume 1,500 W of capacity, then wonder why the UPS overloads.

Step 3: work out the size you need. The calculator multiplies your load by 1.25, which is CyberPower's sizing rule: size the UPS so the load stays under 80% of capacity, and 1 divided by 0.8 is 1.25. It then divides that figure by the power factor and rounds up to the nearest 10 VA, which gives the VA rating you need. Finally it picks the smallest standard size that covers it, from the standard range of 350, 425, 550, 600, 700, 750, 850, 1,000, 1,350, 1,500, 2,200, and 3,000 VA. Schneider Electric gives the same advice in its own words: choose a UPS with a watt capacity 20 to 30% higher than your total load. If no standard size up to 3,000 VA covers the load, the calculator says so plainly and suggests splitting the load across two units.

Step 4: check the load against the 80% guideline. The calculator divides your load by the watt capacity and reports the percentage. APC's own battery guidance recommends not exceeding 80% of the UPS rated capacity, for battery life as well as for runtime: a unit run near full load discharges its battery much faster and ages it faster. At or below 80% the result is a clean pass. Above 80% the result carries a warning. Above 100% the result is an overload: the UPS cannot carry the load at all, and there is no runtime to report.

Step 5: estimate runtime from APC's published chart. Runtime is not calculated from battery capacity, because a buyer choosing a UPS does not know the battery's amp-hour rating, and the honest source for minutes is the manufacturer's own runtime chart. The calculator reads APC's published runtime chart for the Back-UPS Pro 1500, expressed as load fraction: at 5.8% of capacity the chart gives 142 minutes, at 11.6% it gives 73 minutes, at 23.1% it gives 34.5 minutes, at 34.7% it gives 21.2 minutes, at 46.2% it gives 14.5 minutes, at 57.8% it gives 10.5 minutes, at 69.4% it gives 7.8 minutes, at 80.9% it gives 6.0 minutes, at 92.5% it gives 4.6 minutes, and at full load it gives 3.8 minutes. It interpolates linearly between those points, caps the result at 142 minutes below the lowest point, and then reduces it 15% for a battery in typical condition rather than brand new. The 15% reduction is this tool's own conservative adjustment, stated openly: APC's chart is measured with new, fully charged batteries, and APC itself notes that actual runtimes vary with battery age, charge level, environmental conditions, and the characteristics of the connected load. The model was cross-checked against other published figures: APC's BE600M1 gives 23 minutes at 100 W and its BE425M gives 15 minutes at 100 W, and the model predicts 22 and 16 minutes for those units, within a minute of the published numbers.

Worked example 1: a home office on a 1,000 VA UPS. Take a desktop PC at 150 W, a monitor at 25 W, a router at 10 W, a modem at 10 W, and a phone charger at 10 W: the load is 205 W. A 1,000 VA UPS at a 0.6 power factor delivers 600 W, so the load is 34% of capacity, inside the 80% guideline. The load fraction of 0.3417 sits between the chart anchors at 0.231 and 0.347, so the chart value is 21.8 minutes, and after the 15% reduction the estimated runtime is about 19 minutes. For 25% headroom the load needs 257 W, which is 430 VA at a 0.6 power factor, so the smallest standard size that covers it is 550 VA. The comparison shows the same load on a 1,500 VA unit running about 30 minutes and on a 2,200 VA unit running about 51 minutes.

Worked example 2: a gaming setup that overloads a 1,000 VA UPS. Take a gaming desktop at 400 W, two monitors at 50 W, a TV at 100 W, and a game console at 200 W: the load is 750 W. A 1,000 VA UPS at a 0.6 power factor delivers only 600 W, so the load is 125% of capacity and the UPS is overloaded: there is no runtime, because the unit will shut down on battery the moment the power goes out. For 25% headroom the load needs 938 W, which is 1,570 VA, so the smallest standard size that covers it is 2,200 VA. The comparison shows why: on a 1,500 VA unit the load is 83%, over the guideline, with about 5 minutes of runtime, while on a 2,200 VA unit it is 57% with about 9 minutes. The fix is not a bigger VA number for its own sake; it is a watt rating that clears the load with room to spare.

What the calculator does not do. It does not estimate runtime from battery amp-hours, because the battery size is not printed on the box and varies between models with the same VA rating; the chart method is the honest one for a buyer. It does not promise an exact runtime for any model: the chart belongs to one APC model family, the 15% reduction is a planning allowance, and your model's own chart is the authority. It does not cover laser printers, which belong on surge-only outlets, or motor loads such as fans and pumps, which draw starting surges a UPS is not built for. And it does not size a UPS for a whole house: a UPS protects selected electronics, and whole-house backup is a generator's job.

What your result means

The runtime is an estimate with a known method. It comes from APC's published chart, read at your load as a percentage of the watt rating, then reduced 15% for a battery in typical condition. Treat it as a planning number with a margin of error in both directions: a brand-new battery in a cool room will run longer, and a three-year-old battery in a hot room will run shorter. The most useful way to read it is in bands. Under 5 minutes means save your work and shut down now: the UPS is a shutdown device, not a ride-through device. From 5 to 15 minutes covers the great majority of outages, which CyberPower notes usually last about five minutes, and gives you time to save, shut down cleanly, and wait out a flicker. Over 30 minutes means the load is light for the unit, usually network gear on a large UPS, and the UPS will ride through anything short of a real blackout. Over two hours means the load is a rounding error for the unit: a router and a modem on a 1,500 VA UPS will run for hours, and the honest advice is that you bought far more UPS than the job needs.

The load percentage is the number that decides everything. It is your load divided by the watt rating, and the 80% line on the bar is APC's guideline, not this tool's invention. Below 80% the UPS runs cool, the battery ages slowly, and the runtime is what the chart promises. Above 80% the runtime collapses: the chart shows about 5 minutes at 81% load against about 12 minutes at 46% load, so the last fifth of capacity costs more than half the runtime. Above 100% there is no runtime at all, because the UPS overloads and shuts down. If your load lands above 80%, the fix is a bigger unit or fewer devices on battery, and moving the printer or a second monitor to a surge-only outlet is often enough.

The required VA and the recommended size are two different answers. The required VA is the arithmetic: your load times 1.25, divided by the power factor, rounded up to the nearest 10 VA. The recommended size is the smallest standard size that covers it, because UPS units are sold in fixed sizes and there is no 938 VA model. Buying exactly the recommended size is fine; buying one size up buys runtime, not capacity you need, because a bigger battery holds a light load longer. The comparison table exists to make that trade-off visible: the same 205 W home office load runs 19 minutes on a 1,000 VA unit, 30 minutes on a 1,500 VA unit, and 51 minutes on a 2,200 VA unit, all at the same 0.6 power factor.

The comparison verdicts sort sizes into three buckets. Overloaded means the size cannot carry the load at all. Too tight means it can carry it but above the 80% guideline, with a short runtime. Good fit means inside the guideline with at least 10 minutes of runtime. A size can also fit but with a short runtime, which is the honest middle case: the load is safe, but the battery will not hold it long, and stepping up one size is worth considering. The best fit tag marks the smallest size in the comparison that is inside the guideline, because that is the size that covers the load without paying for capacity you will never use.

The VA trap: why 1,500 VA is not 1,500 W

The VA trap is the reason this calculator exists, and it catches careful buyers as well as careless ones. UPS units are sold by their VA rating, printed large on the box, while the watt rating sits in smaller type on the spec sheet. VA is apparent power: the total power the UPS can handle, including the reactive power that flows back and forth without doing work. Watts are real power: the power your devices actually consume. The link between them is the power factor, and Schneider Electric puts it at typically 0.6 to 0.9 for most equipment. Watts equal VA times power factor, so a 1,500 VA UPS at 0.6 delivers 900 W, and at 0.9 it delivers 1,350 W. The VA number alone tells you almost nothing about what the unit can carry.

The trap has a second edge: two units with the same VA rating can carry different loads. APC's Back-UPS Pro 1500 models are rated 1500 VA and 900 W, while CyberPower's CP1500PFCLCD is rated 1500 VA and 1,000 W, because its power factor is 0.67 rather than 0.6. Online double-conversion units run higher still: a 1,500 VA online unit at 0.9 delivers 1,350 W. Comparing two UPS units by VA alone is like comparing two cars by fuel-tank size: the number is real, but it is not the number that decides whether the job gets done. Always compare the watt rating, and always compare your load against it.

UPS sizeWatts at 0.6 PFWatts at 0.9 PFTypically covers
425 VA255 W383 WRouter, modem, and a phone charger
600 VA360 W540 WLaptop, monitor, and network gear
850 VA510 W765 WDesktop, monitor, and network gear
1,000 VA600 W900 WDesktop, two monitors, and a NAS
1,350 VA810 W1,215 WGaming desktop and one monitor
1,500 VA900 W1,350 WGaming desktop, two monitors, and network gear
2,200 VA1,320 W1,980 WHigh-end gaming rig plus TV and console
3,000 VA1,800 W2,700 WWorkstation plus a small server rack

One pattern in the table is worth noticing: at half load, every size gives about the same runtime, roughly 11 minutes after the 15% reduction, because runtime depends on the load as a percentage of capacity. What a bigger unit buys is not more minutes at the same percentage, but a lower percentage for the same load, and the runtime follows the percentage down the chart. That is why the comparison table in the calculator shows runtime growing as the size grows: the load stays fixed while the percentage falls.

Typical device wattages

The presets in the calculator come from published wattage tables, and the table below shows the figure the calculator uses beside the published range it sits inside. Every device varies by model and by what it is doing at the time: a desktop idling at the login screen draws far less than the same desktop rendering video, and a laptop draws far more while charging a flat battery than while topping one up. Use the preset to size, then measure with a plug-in meter if the answer is close to a boundary. If you are sizing a monitor for a new desk, our Monitor Size Finder picks the screen first, and the Laptop Charger Wattage Checker works out what your laptop actually needs from its charger. Network gear going on the UPS is worth sizing as a system: the Mesh WiFi Node Calculator counts the nodes, and each node draws about as much as a router.

DeviceCalculator usesPublished range
Desktop PC (office use)150 W60 to 250 W
Gaming desktop PC400 W300 to 500 W
Laptop (charging)60 W30 to 65 W
Monitor (24 to 27 inch)25 W20 to 40 W
Wi-Fi router10 W5 to 20 W
Modem / ONT10 W5 to 15 W
NAS / home server40 W20 to 50 W
Network switch15 W5 to 30 W
External hard drive10 W5 to 15 W
Inkjet printer40 WAbout 40 W
TV (55 inch LED)100 W60 to 120 W
Game console200 W100 to 200 W
Phone charger10 W5 to 15 W

Two rows deserve a warning. The gaming desktop preset is 400 W, but a high-end graphics card can push a gaming rig past 700 W under load, which is why the calculator adds a note whenever a gaming desktop is in the list: measure it. And the printer row is an inkjet printer only. A laser printer is deliberately absent from the list, because its fuser draws a surge that can overload a UPS; laser printers belong on surge-only outlets, never on battery outlets. If your NAS holds security camera recordings, size its UPS with the storage in mind too: our Home Security Camera Storage Calculator works out how much footage the NAS has to hold.

Common mistakes to avoid

Sizing by VA instead of watts. The classic mistake, and the one this calculator is built to prevent. A 1,500 VA UPS is not a 1,500 W UPS: at the typical 0.6 power factor it delivers 900 W, and a load of 1,000 W will overload it. Always compare your load with the watt rating on the spec sheet, and treat the VA number as a category label, not a capacity.

Sizing by the power supply label. A desktop with a 750 W power supply does not draw 750 W: the label is the most the supply can deliver, not what the parts use. A light-use desktop with a 750 W supply often draws 300 to 450 W, and sizing to the label buys a UPS twice as big as the job needs. Size by measured or typical draw, not by the label, and use a plug-in meter when the answer matters.

Forgetting the monitor and the network gear. A UPS that keeps the PC alive but lets the monitor and the router die has saved nothing: you cannot see your work, and the network is gone. Count every device that must keep running, including the monitor, the router, the modem, and the switch. The load list in the calculator is built for exactly this, and the preset buttons load the whole desk at once so nothing is missed.

Plugging a laser printer into a battery outlet. A laser printer's fuser draws a surge far above its printing wattage when it heats up, and that surge can overload a UPS and shut it down during an outage, taking the computer with it. Laser printers go on surge-only outlets. Inkjet printers are safe on battery at about 40 W, but they still belong on surge-only outlets if the battery is needed for the machines that hold your work.

Trusting the headline runtime. A box that says 68 minutes is quoting the runtime at a 100 W load on a 1,500 VA unit, not at your load. Runtime is a curve, not a number: the same unit gives 3 minutes at full load and 11 minutes at half load. Always read the runtime chart at your own watt draw, which is what this calculator does, and never compare two units by their headline minutes.

Running at 100% load. A UPS run at its ceiling gives its shortest runtime, runs its battery hottest, and ages it fastest. APC recommends staying at or below 80% of rated capacity, and the chart shows why: moving from 46% load to 81% load cuts runtime from about 12 minutes to about 5 minutes. If the calculator shows a load above 80%, step up a size or move a device to a surge-only outlet.

Ignoring battery age. Most UPS batteries last three to five years, and runtime is the first thing to fade as a battery ages. APC warns that every 15 degrees Fahrenheit above the 68 to 77 degree ideal cuts battery life in half, so a UPS in a hot attic ages twice as fast as one in a cool office. If your runtime has dropped noticeably and the battery is over three years old, replace the battery: most models take a user-replaceable battery, and a fresh battery restores the chart runtime.

Buying a simulated sine wave UPS for a NAS or a modern desktop. Power supplies with active power factor correction, which includes most modern desktops and NAS units, can switch off the moment a simulated sine wave UPS takes over, because the stepped waveform looks like bad power. The machine the UPS was bought to protect shuts down anyway. If the calculator's NAS note appears, take it seriously: a pure sine wave model costs more, but it is the only kind that keeps active PFC supplies running.

Frequently asked questions

What size UPS do I need for my computer?

Add up the watts of everything that must keep running: a typical office desktop draws about 150 W, a monitor about 25 W, and a router and modem about 10 W each, so a home office load is often near 200 W. Multiply that total by 1.25 for headroom, then divide by the power factor, usually 0.6, to get the VA rating: 200 W times 1.25 is 250 W, and 250 divided by 0.6 is about 417 VA, so a 425 VA unit is the smallest standard size that covers it. Enter your own devices in the calculator above for an exact answer, and keep the load at or below 80% of the watt rating.

Is 1500VA enough for a gaming PC?

Usually yes, but it depends on the graphics card and the monitor count. A 1,500 VA UPS at a 0.6 power factor delivers 900 W, and a gaming desktop with one monitor and a router draws about 435 W, which is 48% of capacity and leaves comfortable headroom. A high-end rig with two monitors, a TV, and a console can reach 725 W, which is 81% of capacity and over the 80% guideline, so it needs a 2,200 VA unit. Size by the watt rating, not the VA number, and measure a gaming PC with a plug-in meter, because gaming loads spike above their typical draw.

How long will a 1500VA UPS run my computer?

It depends on the load, not the VA rating. A 1,500 VA unit rated at 900 W runs about 3 minutes at full load and about 11 minutes at half load, according to APC's published runtime chart, and a light load of 100 W runs about an hour. Halving the load more than doubles the runtime, because lead-acid batteries deliver less of their stored energy at high discharge rates. The calculator above reads your load as a percentage of the watt rating against APC's published chart and reduces the result 15% for a battery in typical condition, so treat the number as an estimate, not a promise.

What is the difference between VA and watts on a UPS?

VA, or volt-amperes, is apparent power: the total power the UPS can handle. Watts are real power: the power your devices actually consume. The two are linked by the power factor, which Schneider Electric puts at typically 0.6 to 0.9 for most equipment: watts equal VA times power factor, so a 1,500 VA UPS at a 0.6 power factor delivers 900 W. That is why two units with the same VA rating can carry different loads, and why you should always size by the watt rating printed on the spec sheet.

Can I plug a laser printer into a UPS?

No. A laser printer's fuser draws a large surge when it heats up, far above its printing wattage, and that surge can overload a UPS and shut it down in the middle of an outage. Plug a laser printer into a surge-only outlet instead, and keep the battery outlets for the computer, the monitor, and the network gear. An inkjet printer is safe on battery, at about 40 W, but it is still better on a surge-only outlet if you can spare the battery for the machines that hold your work.

Why does my UPS runtime keep getting shorter?

The battery is aging. APC says most UPS batteries last three to five years, and as a sealed lead-acid battery ages, sulfation hardens on its plates and it holds less charge, so the same load runs for less time. Heat speeds the decline: APC warns that every 15 degrees Fahrenheit above the 68 to 77 degree ideal cuts battery life in half. Heavy loads shorten runtime too, because frequent deep discharges wear the battery faster. If your runtime has dropped noticeably and the battery is over three years old, replace the battery rather than the whole unit.

Should I buy a pure sine wave UPS?

Yes if you protect a NAS, a server, or a modern desktop with an active PFC power supply. Those power supplies can switch off the moment a simulated sine wave UPS takes over, because the stepped waveform looks like bad power to them, and the machine you bought the UPS to protect shuts down anyway. A pure sine wave UPS produces clean power identical to the grid, so active PFC supplies stay on. For a router, a modem, a monitor, or an older PC, a simulated sine wave unit is fine and costs less.

Sources

Every figure on this page comes from one of the sources below, each accessed 20 November 2026. Where sources disagree, the page says so and follows the more conservative figure.

  • se.com — Schneider Electric (APC), UPS buying guide: power factor typically 0.6 to 0.9 for most equipment, 500 W divided by 0.8 is 625 VA minimum, choose a watt capacity 20 to 30% higher than total load, basic units provide 5 to 15 minutes of runtime. Accessed 20 November 2026.
  • se.com — Schneider Electric (APC), expected life of a VRLA battery: most APC batteries last three to five years, optimal temperature 20 to 25 degrees C (68 to 77 degrees F), every 8 degrees C (15 degrees F) increase cuts battery life in half, do not exceed 80% of the UPS rated capacity, end of life at approximately five years. Accessed 20 November 2026.
  • thebridgemi.org — APC Back-UPS Pro BR1500G published runtime chart: 50 W at 142 minutes, 100 W at 73 minutes, 200 W at 34.5 minutes, 300 W at 21.2 minutes, 400 W at 14.5 minutes, 500 W at 10.5 minutes, 600 W at 7.8 minutes, 700 W at 6.0 minutes, 800 W at 4.6 minutes, full load 865 W at 3.8 minutes, half load at 13.0 minutes. Accessed 20 November 2026.
  • assets.rs-online.com — APC Back-UPS Pro 1500 datasheet: the runtime graph is based on actual measured runtime data with new, fully charged batteries and a balanced resistive load; actual runtimes vary with battery age, battery charge level, environmental conditions, and the characteristics of the connected load. Accessed 20 November 2026.
  • bhphotovideo.com — APC BR1500G specifications: 1500 VA and 865 W, 4 minutes at full load, 13 minutes at half load. Accessed 20 November 2026.
  • bhphotovideo.com — APC BN1500M2 specifications: 1500 VA and 900 W, 3.1 minutes at full load, 11.4 minutes at half load. Accessed 20 November 2026.
  • whatbatteryfor.com — CyberPower's 125% rule: add up the watts and multiply by 1.25 to keep the load under 80% of the UPS capacity; most power outages last about five minutes. Accessed 20 November 2026.
  • ankersolix.com — Home-office wattage table: laptop 30 to 65 W, desktop in office use 60 to 250 W, monitor 20 to 40 W, router and modem combined 10 to 20 W. Accessed 20 November 2026.
  • blog.ecoflow.com — Appliance wattage chart: desktop computer 100 to 400 W, Wi-Fi router 5 to 20 W, ethernet switch 5 to 30 W, external hard drive 5 to 15 W, modem 5 to 15 W, mobile phone charger 5 to 15 W. Accessed 20 November 2026.
  • wattsizer.org — Audited appliance wattage chart: desktop PC under load 120 W, gaming desktop 500 W, monitor 15 to 18 W, router plus modem 15 W, inkjet printer 40 W, laptop 50 W. Accessed 20 November 2026.
  • outagemath.com — Appliance wattage chart: TV 55 inch LED 100 W, desktop PC plus monitor 150 W, game console 200 W, Wi-Fi router plus modem 15 W, laptop 50 W. Accessed 20 November 2026.
  • tiptech.sk — Device power use: home server and NAS 20 to 50 W, Wi-Fi router 5 to 12 W, modem 5 to 10 W, monitor 15 to 40 W, television 50 to 120 W. Accessed 20 November 2026.
  • bestairpurifierpicks.com — UPS model comparison: APC BE600M1 rated 23 minutes at 100 W, APC BE425M rated 15 minutes at 100 W, APC BX1500M rated 68 minutes at 100 W; used to cross-check the load-fraction runtime model. Accessed 20 November 2026.
  • computerinfobits.com — Gaming PC UPS sizing: CyberPower CP1500PFCLCD runs 10 minutes at half load and 2.5 minutes at full load; 1500 VA units range from 900 W to 1000 W by power factor. Accessed 20 November 2026.
  • itbroker.com — UPS runtime method: the Peukert exponent for VRLA AGM batteries runs 1.05 to 1.15, and batteries are commonly considered at end of life at 80% of rated capacity. Accessed 20 November 2026.
  • solartap.com — Electrical appliances power consumption chart: gaming desktop computer 300 to 500 W, standard desktop computer 65 to 250 W, LCD TV 60 to 150 W, LCD monitor 35 to 80 W, router 5 to 20 W, modem 2 to 20 W. Accessed 20 November 2026.