Off-Grid Solar and Battery Bank Sizer
Verified Last reviewed: 22 November 2026. Page history
Solar array
Panels
Battery bank
Inverter
Notes and how it works
Daily electricity use
The average US home uses about 30 kWh a day (EIA, 2022). A small off-grid cabin uses 2 to 5 kWh a day. Divide a monthly bill by 30 if you only know the monthly figure.
Daily electricity use
Tick each load you run and set its hours per day. Fridge and freezer hours are compressor run hours, about 8 a day, not 24. Wattages are typical values from the US Department of Energy Energy Saver list and the Champion Power Equipment wattage chart. Check your own appliance nameplates for exact figures.
Peak sun hours per day
Peak sun hours are the equivalent hours of full 1,000 W per square meter sun, not daylight hours. The US averages about 5 a day; Arizona averages 6.54 and Washington 3.95. Use your darkest month, from PVWatts for your address.
Days of autonomy
How many days the battery alone must carry your loads. Two to three days is standard for a full-time off-grid home; one day is enough with a backup generator.
System voltage and battery type
48 V suits most farmhouse systems. 12 V is for small systems only: above about 3 kWh a day the currents get very large. Lead-acid gives 50% usable capacity, lithium 80%.
Panel wattage and peak load (optional)
Most home panels quoted in 2026 are 400 to 460 watts. Peak load is the watts of everything running at the same time; it sizes the inverter. In load mode the peak is worked out from your ticked loads, unless you enter a figure here.
Free to use — no sign-up, no paywall. Spotted a mistake? Tell us — we fix reported errors within 24 hours.
Your inputs stay in your browser: every calculation runs on your device, and nothing you type is sent to our servers.
Last reviewed: 22 November 2026. Reviewed every 180 days; next review due 22 May 2027.
How to use the Off-Grid Solar and Battery Bank Sizer
An off-grid farmhouse runs on four numbers: how much electricity you use each day, how much sun your site gets, how many sunless days the battery must cover, and how much power everything draws at once. This sizer turns those four numbers into the four answers that decide the system: the solar array size in watts, the number of panels, the battery bank size in amp-hours and kilowatt-hours, and the inverter size. It works in two ways. If you know your daily use, enter it directly in kilowatt-hours. If you do not, tick the loads in the built-in estimator and it adds up your daily use from typical appliance wattages, then sizes the system from that total.
The sizer is built for farmhouses and rural homes, where the loads are different from a city apartment: a well pump that starts with a surge, a chest freezer in the barn, a furnace fan, and lights spread across outbuildings. The estimator covers 22 common farmhouse loads plus LED lighting, with wattages taken from the US Department of Energy Energy Saver list and the Champion Power Equipment wattage chart, both re-checked on 22 November 2026. Every figure the tool prints can be checked by hand: the steps section shows each calculation with its inputs, so you can follow the arithmetic from your daily use to the panel count without trusting a black box.
To get your result, follow these steps:
- Enter your daily electricity use. Choose "Enter kWh directly" and type your daily use in kilowatt-hours, from 0.1 to 500. The average US home uses about 30 kWh a day: the Energy Information Administration reports 10,791 kWh a year for the average residential customer in 2022, which is 899 kWh a month and about 29.6 kWh a day. A careful off-grid farmhouse usually lands between 5 and 15 kWh a day, because the big electric loads, water heating, clothes drying, and space heating, run on gas, propane, or wood instead. If you only know a monthly figure, divide it by 30. If you have a utility bill, the daily average on the bill is the most honest starting point you have.
- Or build from your loads. Choose "Build from my loads", tick each appliance you run, and set its hours per day. Fridge and freezer hours are compressor run hours, about 8 a day, not 24: the compressor cycles on and off, and the Department of Energy guidance is to divide the plugged-in time by three. The estimator adds watts times hours for every ticked load and shows the daily total in watt-hours. It also works out your peak load from the ticked loads, which sizes the inverter, and it tracks motor starting surge for the well pump, sump pump, furnace fan, fridge, and freezer. When loads are ticked, they govern: any kWh figure entered directly is ignored, and the result says so.
- Enter peak sun hours. Peak sun hours are the equivalent hours of full 1,000 W per square meter sun your site averages each day, not the hours of daylight. The US averages about 5 a day. Arizona averages 6.54, New Mexico 6.42, and Nevada 6.41 at the sunny end; Washington averages 3.95 and Alaska 3.17 at the cloudy end. Enter the figure for your darkest month, not the yearly average: an off-grid system that only balances in June goes dark in December. The free PVWatts calculator from the National Laboratory of the Rockies gives month-by-month sun hours for any US address. The regional table below gives the ranges to start from.
- Enter days of autonomy. Days of autonomy are how many days the battery alone must carry your loads with little or no sun. Two to three days is the standard recommendation for a full-time off-grid home. One day is enough if you have a backup generator that can recharge the bank, and four or more days is for homes in long gray winters with no generator. Every extra day adds the same again to the battery bank, so autonomy is the most expensive input in the whole calculation: doubling it doubles the bank.
- Pick the system voltage and battery type. System voltage is 12, 24, or 48 volts. 48 V suits most farmhouse systems. 12 V is for small systems only: above about 3 kWh a day the currents get very large, and the tool warns you. Battery type sets the usable depth of discharge: lead-acid gives 50% usable capacity, lithium iron phosphate (LiFePO4) gives 80%. A lead-acid bank must therefore be 60% larger in rated capacity than a lithium bank for the same usable energy, because 0.5 divided by 0.8 is 0.625, so the lithium bank needs only 62.5% of the rated capacity.
- Set the panel wattage. Most home panels quoted in the first half of 2026 are 400 to 460 watts, with the largest share, 47%, quoted between 430 and 440 watts, according to EnergySage Marketplace data. The default is 400 W. Enter the wattage of the panel you plan to buy and the count adjusts: higher-wattage panels mean fewer panels for the same array.
- Enter peak load, if you know it. Peak load is the watts of everything running at the same time, and it sizes the inverter. In load mode the tool works it out from your ticked loads, unless you enter a figure here, in which case your figure governs. In direct mode there is no peak figure unless you enter one, and the inverter is left unsized with a note saying so. Add up the running watts of everything that runs together, and remember that motors need extra watts to start: the tool adds the largest single starting surge on top of the peak when it knows the loads.
The tool updates as you type, so you can try different numbers quickly. Try the example buttons under the form: the farmhouse example is a 5 kWh a day home with 4.5 peak sun hours, 2 days of autonomy, a 48 V lithium bank, and a 3,000 W peak load; the cabin example is a 2 kWh a day cabin on 12 V lead-acid with 3 days of autonomy; and the loads example builds a farmhouse from its appliances, well pump included. Read the full result, not just the headline. The cards show the array, the panel count, the battery bank, and the inverter. The guidance explains the result in plain language, the warnings flag the inputs that need a second look, the steps print the full working so you can check every figure, and the notes cover the method and its limits.
How it works
The sizer runs five calculations in order: your daily energy use, your solar array size, your panel count, your battery bank size, and your inverter size. Each one uses the result of the one before it, and the steps section on the page prints all five so you can check them against your own arithmetic. The formulas are the standard off-grid sizing formulas used across the solar industry, verified against published sizing guides on 22 November 2026.
Step 1: daily energy use
Daily energy is the foundation everything else stands on, and it is the input most worth getting right. In direct mode the tool takes the kilowatt-hours you enter and converts to watt-hours: 5 kWh a day is 5,000 Wh a day. In load mode it adds up each load as watts times hours per day: a refrigerator at 275 W running 8 compressor hours a day uses 2,200 Wh, a well pump at 875 W running 1 hour uses 875 Wh, and ten LED bulbs at 12 W each running 6 hours use 720 Wh. The total is rounded to the nearest whole watt-hour, and each load row is rounded the same way first, so the printed rows always add up to the printed total exactly.
The honest way to get this number is a month of real measurements. A plug-in meter on the fridge and freezer for a week tells you more than any chart, because a 2024 Energy Star refrigerator uses far less than a 2003 side-by-side. The estimator wattages are midpoints of published ranges, which means they overstate a new efficient appliance and understate an old one. If your loads are mostly new and efficient, enter a lower daily figure directly, or cut the hours on the big loads. If they are old, the estimator total is the safer number to size from.
Step 2: solar array size
The array formula is: array watts equals daily watt-hours divided by peak sun hours, times 1.3 for system losses. The 1.3 factor covers inverter losses, wiring losses, and battery round-trip losses, and it matches the standard off-grid practice of adding about 30% for losses: published sizing guides use daily energy times 1.3 divided by peak sun hours, and the PVWatts derate of 0.77 gives the same factor, since 1 divided by 0.77 is 1.30. The result is rounded up to the nearest 10 W, so the array is never smaller than the calculation asks for.
Worked example: a farmhouse uses 5,000 Wh a day with 4.5 peak sun hours. 5,000 divided by 4.5 is 1,111.1 W, times 1.3 is 1,444.4 W, rounded up to 1,450 W. The same home in Arizona at 6.5 peak sun hours needs 5,000 divided by 6.5 times 1.3, which is 1,000 W exactly. In Washington at 3.95 peak sun hours it needs 5,000 divided by 3.95 times 1.3, which is 1,645.6 W, rounded up to 1,650 W. Sun hours move the answer more than any other input except daily use itself.
Step 3: panel count
Panel count is the array watts divided by the panel wattage, rounded up to a whole panel. The count is worked out from the rounded-up array figure, not the raw figure, so the installed array is always at least the size the calculation asks for. At 1,450 W with 400 W panels, 1,450 divided by 400 is 3.625 panels, rounded up to 4 panels, and the installed array is 1,600 W. At 950 W with 105 W panels, 950 divided by 105 is 9.05 panels, rounded up to 10 panels, and the installed array is 1,050 W. Counting from the raw figure instead would have given 9 panels and 945 W, below the 950 W the home needs: a small trap that this tool does not fall into.
Step 4: battery bank size
The battery formula is: battery amp-hours equals daily watt-hours times days of autonomy, divided by depth of discharge times system voltage. Depth of discharge is the usable share of the battery: 50% for lead-acid, 80% for lithium. The result is rounded up to a whole amp-hour. Rated energy in kilowatt-hours is amp-hours times volts divided by 1,000, and usable energy is rated energy times depth of discharge. Usable energy is computed from the rounded rated figure, so the printed equation always balances: a 12.53 kWh bank at 80% depth of discharge gives 10.02 kWh usable, and 12.53 times 0.8 is 10.024, which rounds to 10.02.
Worked example: the same 5,000 Wh a day farmhouse, 2 days of autonomy, 48 V, lithium at 80%. 5,000 times 2 is 10,000 Wh, divided by 0.8 times 48, which is 38.4, gives 260.4 Ah, rounded up to 261 Ah. Rated energy is 261 times 48 divided by 1,000, which is 12.53 kWh, and usable energy is 12.53 times 0.8, which is 10.02 kWh, covering the 10 kWh the two days need. The same home on lead-acid at 50% needs 10,000 divided by 24, which is 416.7 Ah, rounded up to 417 Ah, a 20.02 kWh bank with 10.01 kWh usable. The lead-acid bank is 60% larger in rated capacity for the same usable energy.
One rounding detail is worth knowing. Because both the rated energy and the usable energy are rounded to two decimals for display, the printed usable figure can land a hundredth of a kilowatt-hour below the printed requirement in rare cases, even though the true bank holds more than enough. When that happens the tool adds 1 Ah, very rarely 2 or 3, and says so in the battery step, so the printed figures always cover the full autonomy period. The bank is never undersized on the numbers you see.
Step 5: inverter size
The inverter formula is: inverter continuous watts equals peak load watts times 1.25, rounded up to the nearest 100 W. The 25% headroom keeps the inverter out of its top end, where efficiency falls and heat rises, and it leaves room for a load you forgot. A 3,000 W peak load needs 3,750 W, rounded up to a 3,800 W inverter. An 8,000 W peak load needs 10,000 W exactly.
Motors need more than their running watts to start, and the inverter surge rating must cover that. The tool adds the largest single starting surge to the peak load: a 1/2 HP well pump draws 875 W running and 1,750 W to start, an extra 875 W, so a 3,151 W peak load with that pump needs a surge rating of 3,151 plus 875, which is 4,026 W, rounded up to 4,100 W. Only the largest single surge is added, because motors start one at a time, not all at once. If two big motors can start together, the surge is larger than this figure, and the inverter needs checking against both.
Worked example: the farmhouse from its loads
A farmhouse ticks seven loads and eight LED bulbs: a refrigerator at 275 W for 8 hours (2,200 Wh), a chest freezer at 300 W for 8 hours (2,400 Wh), a 1/2 HP well pump at 875 W for 1 hour (875 Wh), a microwave at 925 W for 0.25 hours (231 Wh, since 925 times 0.25 is 231.25, rounded to 231), a clothes washer at 425 W for 1 hour (425 Wh), a TV at 240 W for 4 hours (960 Wh), a Wi-Fi router at 15 W for 24 hours (360 Wh), and 8 LED bulbs at 12 W each, 96 W, for 5 hours (480 Wh). The total is 7,931 Wh a day, or 7.93 kWh. At 5 peak sun hours the array is 7,931 divided by 5 times 1.3, which is 2,062.1 W, rounded up to 2,070 W, or 6 panels of 400 W (2,400 W installed). For 2 days of autonomy at 48 V on lithium, the bank is 7,931 times 2 divided by 38.4, which is 413.1 Ah, rounded up to 414 Ah, a 19.87 kWh bank with 15.90 kWh usable. Peak load is the running watts added together, 3,151 W, so the inverter is 3,151 times 1.25, which is 3,938.75 W, rounded up to 4,000 W continuous, with a 4,100 W surge rating for the well pump start.
Worked example: the small cabin on lead-acid
A cabin uses 2,000 Wh a day with 3.5 peak sun hours, 3 days of autonomy, a 12 V lead-acid bank, and 400 W panels. The array is 2,000 divided by 3.5 times 1.3, which is 742.9 W, rounded up to 750 W, or 2 panels (800 W installed). The bank is 2,000 times 3 divided by 0.5 times 12, which is 6, giving exactly 1,000 Ah, a 12 kWh bank with 6 kWh usable, covering the 6 kWh the three days need. The tool warns that three or more days of autonomy on lead-acid makes a very large, heavy bank, and that a lithium bank would need only 62.5% of the rated capacity for the same usable energy.
Worked example: the average US home, off-grid
The average US home uses about 30 kWh a day. At 5 peak sun hours with 2 days of autonomy on a 48 V lithium bank, the array is 30,000 divided by 5 times 1.3, which is 7,800 W exactly, or 20 panels of 400 W (8,000 W installed). The bank is 30,000 times 2 divided by 38.4, which is 1,562.5 Ah, rounded up to 1,563 Ah, a 75.02 kWh bank with 60.02 kWh usable. With an 8,000 W peak load the inverter is 10,000 W exactly. The example shows why off-grid homes cut the big electric loads first: at 30 kWh a day the battery bank alone is 75 kWh of rated capacity, and halving daily use to 15 kWh halves every number in the system.
Peak sun hours by region
Peak sun hours vary more than twofold across the United States, and the range inside a single state can be as wide as the range between states: California runs from about 4.5 peak sun hours on the foggy north coast to more than 6 in the southeastern desert. The table below gives annual average ranges by region, drawn from state data based on the National Solar Radiation Database, the same data behind PVWatts. Treat every figure as a starting point. Your address-level number from PVWatts, for your darkest month, is the figure to size from, and it can sit a full hour or more below the annual average in northern winters.
| Region | States | Annual average peak sun hours |
|---|---|---|
| Southwest | Arizona, New Mexico, Nevada | 5.5 to 6.5 |
| Hawaii and Southern California | Hawaii, southern California | 5.5 to 6.0 |
| Mountain West | Colorado, Utah, Wyoming | 5.0 to 5.5 |
| Southern Plains | Texas, Oklahoma, Kansas | 5.0 to 5.5 |
| Southeast | Florida, Georgia, the Carolinas | 4.5 to 5.5 |
| Midwest | Illinois, Ohio, Indiana, Iowa | 4.0 to 4.5 |
| Northeast | New York, Pennsylvania, New England | 3.5 to 4.5 |
| Pacific Northwest | Washington, Oregon | 3.5 to 4.0 |
| Alaska | Alaska | 2.5 to 3.5 |
| US average | All states | About 5.0 |
Two cautions belong with this table. First, state averages hide the spread: the sunniest and cloudiest parts of Texas differ by more than an hour a day, and a shaded valley floor can sit well below its county average. Second, the annual average is the wrong number for off-grid sizing. December in Oregon delivers about 2 peak sun hours a day against a July figure above 6, and a system sized on the yearly average of about 4 runs short all winter. Size on the worst month, and let the summer surplus go unused. The tool warns you when peak sun hours fall below 3, and again when they rise above 6.5, which is higher than any US state annual average: Arizona, the sunniest state, averages 6.54, so a figure above 6.5 is almost certainly a summer number.
Panel tilt and direction shift the number too. A fixed array tilted at roughly your latitude and facing true south collects the most energy over the year in the northern hemisphere. A steeper tilt favors winter production, which is what an off-grid home needs, at the cost of some summer output. Shading is the silent killer: a panel shaded for an hour at midday can lose far more than an hour of production, because the shaded cells drag down the whole string unless the panels have optimizers or the array uses microinverters. PVWatts lets you enter tilt, direction, and system losses, and its monthly table shows the winter dip directly.
The load estimator wattages
The estimator uses one wattage per load, chosen as the midpoint of a published range, or the published single value where the source gives one. The two sources are the US Department of Energy Energy Saver list of typical appliance wattages, as reproduced by Virginia Cooperative Extension, and the Champion Power Equipment generator wattage chart. Both were re-checked on 22 November 2026. The table below shows every load, the wattage the tool uses, the published range behind it, the default hours, and the daily energy at those hours.
| Load | Watts used | Published range | Default hours | Wh per day |
|---|---|---|---|---|
| Refrigerator | 275 | 150 to 400 (Champion) | 8 | 2,200 |
| Chest freezer | 300 | 100 to 500 (Champion) | 8 | 2,400 |
| Microwave oven | 925 | 750 to 1,100 (DOE) | 0.25 | 231 |
| Coffee maker | 1,050 | 900 to 1,200 (DOE) | 0.25 | 263 |
| Dishwasher | 1,800 | 1,200 to 2,400 (DOE) | 1 | 1,800 |
| Toaster | 1,100 | 800 to 1,400 (DOE) | 0.1 | 110 |
| Well pump (1/2 HP) | 875 | 750 to 1,000 (Champion) | 1 | 875 |
| Well pump (1 HP) | 1,500 | 1,000 to 2,000 (Champion) | 1 | 1,500 |
| Sump pump (1/2 HP) | 925 | 800 to 1,050 (Champion) | 1 | 925 |
| Electric water heater | 5,000 | 4,500 to 5,500 (DOE) | 3 | 15,000 |
| Clothes washer | 425 | 350 to 500 (DOE) | 1 | 425 |
| Electric clothes dryer | 3,400 | 1,800 to 5,000 (DOE) | 1 | 3,400 |
| Ceiling fan | 120 | 65 to 175 (DOE) | 8 | 960 |
| Portable space heater | 1,125 | 750 to 1,500 (DOE) | 4 | 4,500 |
| Furnace fan (gas or oil furnace) | 550 | 300 to 800, 1/2 HP (Champion) | 6 | 3,300 |
| TV (32 to 55 inch) | 240 | 80 to 400 (Champion) | 4 | 960 |
| Laptop computer | 50 | 50 (DOE) | 6 | 300 |
| Desktop computer and monitor | 270 | 120 plus 150 (DOE) | 6 | 1,620 |
| Wi-Fi router and modem | 15 | 10 to 20 | 24 | 360 |
| Phone charger | 10 | 10 | 2 | 20 |
| Hair dryer | 1,540 | 1,200 to 1,875 (DOE) | 0.25 | 385 |
| Vacuum cleaner | 1,220 | 1,000 to 1,440 (DOE) | 0.5 | 610 |
| LED bulb | 12 | 8 to 15 (Champion) | 5 | 60 per bulb |
Three of these figures deserve a note, because the sources disagree and the tool had to choose. First, the refrigerator: the Department of Energy list gives 725 W for a frost-free 16 cubic foot model, but that is a nameplate maximum for an older unit, while Champion gives 150 to 400 W running and modern Energy Star models draw about 100 to 200 W. The tool uses the Champion midpoint of 275 W, which matches the figure in our Home Generator Size Calculator, and the 8-hour default already accounts for compressor cycling. Second, the chest freezer: Champion gives 100 to 500 W, and the tool uses the 300 W midpoint, while modern chest freezers draw about 80 to 200 W running; if yours is new, cut the hours or enter your daily use directly. Third, the TV: Champion gives 80 to 400 W, and the tool uses the 240 W midpoint, while a modern 55 inch LED set draws about 60 to 120 W; the range covers older and larger sets, and the midpoint is the honest middle of the published range rather than the modern low end.
The furnace fan is the other judgment call. The Department of Energy list gives 750 W with no motor size attached, while Champion gives 300 to 800 W for a 1/2 HP fan, and the tool uses the 550 W midpoint for a 1/2 HP unit, matching the generator sizer. A larger blower motor draws more: check the motor plate. The hair dryer figure of 1,540 W is the midpoint of the Department of Energy range of 1,200 to 1,875 W, which is 1,537.5 W, rounded to the nearest 10 W. Every other figure in the table is an exact midpoint or a published single value.
Two loads dominate any farmhouse list, and both are usually better served off electricity. An electric water heater at 5,000 W for 3 hours uses 15,000 Wh a day, more than the rest of the farmhouse example put together, and an electric dryer at 3,400 W for an hour uses 3,400 Wh a load. Off-grid homes normally heat water with propane, a heat pump, or solar thermal, and dry clothes on a line or with a gas dryer. If you keep either electric load, size honestly for it: the water heater alone, at 15 kWh a day with 4.5 peak sun hours, needs an array of 15,000 divided by 4.5 times 1.3, which is 4,333.3 W, rounded up to 4,340 W, and a 2-day lithium bank at 48 V of 15,000 times 2 divided by 38.4, which is 781.25 Ah, rounded up to 782 Ah. Our Tankless Water Heater Size Calculator and Washer Dryer Capacity Finder help with the gas and sizing side of those choices.
Lead-acid vs lithium batteries
The battery choice changes the bank size, the weight, the maintenance, and the lifetime cost, all at once. Lead-acid is cheaper to buy and heavier to own. Lithium iron phosphate costs more up front and returns it in usable capacity and cycle life. The table below compares the two on the figures that matter for sizing.
| Lead-acid (flooded, AGM, gel) | Lithium (LiFePO4) | |
|---|---|---|
| Usable depth of discharge | 50% | 80% |
| Round-trip efficiency | 75 to 85% | About 95% |
| Cycle life at stated depth of discharge | 500 to 1,500 cycles | 3,000 to 7,000 cycles |
| Rated capacity for 10 kWh usable | 20 kWh | 12.5 kWh |
| Cold weather | Capacity drops 20 to 40% in the cold | Must not be charged below 0 degrees C (32 degrees F) without heating |
| Maintenance | Flooded needs watering and ventilation; AGM and gel are sealed | No watering; battery management system handles balancing |
| Weight for the same usable energy | About 4 to 5 times heavier | Lightest per usable kWh |
The depth-of-discharge numbers are the ones this tool uses: 50% for lead-acid, 80% for lithium. Some lithium manufacturers allow 90% or even 100% discharge, and some sizing guides use 85% for LiFePO4. The tool uses 80% because it is the conservative standard across the published guides, and because a battery that is never pushed to its limit lasts longer. If your battery datasheet allows 90% routinely, your bank could be about 11% smaller than the tool says: divide the tool bank by 0.9 and multiply by 0.8. For lead-acid, 50% is a hard limit for reasonable life: discharging to 80% regularly cuts the cycle count sharply, and the tool warns you when three or more days of autonomy on lead-acid makes the bank very large.
The efficiency gap matters for the array as well as the bank. A lead-acid bank returns 75 to 85% of the energy put into it, against about 95% for lithium, so the same loads need a slightly larger array on lead-acid to make up the round-trip loss. The tool 1.3 loss factor already covers battery round-trip losses at a typical level, so no extra adjustment is needed for planning, but the gap is real and it is one more reason lithium has become the default for new off-grid systems. For a backup power view of the same question, our Propane Tank Runtime Calculator sizes the generator fuel side, and our Home Generator Size Calculator sizes the generator itself.
Choosing system voltage: 12 V, 24 V, or 48 V
Voltage is about current. The same power at 12 V carries four times the current it carries at 48 V, and current is what decides cable thickness, fuse sizes, and voltage drop. A 3,000 W inverter draws 250 amps from a 12 V bank, 125 amps at 24 V, and 62.5 amps at 48 V. The 12 V version needs very thick, expensive cables and still loses more energy as heat. That is why systems above roughly 2 to 3 kWh a day are usually built at 24 V or 48 V, and why the tool warns when a 12 V system is asked to carry more than 3 kWh a day, and when a 24 V system is asked to carry more than 10 kWh a day.
12 V suits small systems: a cabin, a workshop, a barn, or a weekend place with a small array and a modest inverter. The parts are common and cheap, and 12 V appliances and lights run directly off the bank. 24 V suits medium systems, roughly 2,000 to 3,000 W inverters, large RVs, and small cabins. 48 V suits full-time homes: it halves the current again against 24 V, it is the standard for modern all-in-one inverter and charge controller units, and it keeps the cable runs manageable across a farmhouse and its outbuildings. The tool does not force the choice. It sizes the bank at the voltage you pick, and warns when the voltage is small for the load.
One practical note: battery banks are built from series and parallel strings, and the voltage you pick decides the string layout. A 48 V bank from 12 V batteries needs four in series; a 48 V bank from 51.2 V lithium modules needs one module per string, paralleled for capacity. The tool gives the total amp-hours at your system voltage, not the string layout: your installer works out the strings from the battery you buy. The amp-hour figure is the same either way, because amp-hours at system voltage already account for the series arrangement.
Inverter sizing and motor surge
The inverter is sized by peak load, not by daily energy. A home that uses 5 kWh a day but never runs more than 2,000 W at once needs a smaller inverter than a home that uses 3 kWh a day with a 5,000 W well pump and a 3,400 W dryer running together. The tool multiplies peak load by 1.25 for headroom and rounds up to the nearest 100 W. The headroom matters: an inverter run at its continuous limit runs hot, and its efficiency falls, so a 25% margin is cheap insurance against both.
Motor starting surge is the detail that trips up most first-time designs. A motor draws two to three times its running watts for a fraction of a second at startup. The well pump is usually the worst offender on a farm: a 1/2 HP pump draws 875 W running and 1,750 W to start, and a 1 HP pump draws 1,500 W running and 3,000 W to start. The refrigerator adds 725 W above its 275 W running draw, the chest freezer 450 W above 300 W, the sump pump 800 W above 925 W, and the furnace fan 650 W above 550 W. The tool adds only the largest single extra surge to the peak, because motors start one at a time. If your well pump and your sump pump can start in the same second, add both surges by hand and check the inverter surge rating against that total.
Inverter surge ratings are usually about double the continuous rating, and they last for a few seconds, which is long enough for a motor start. Check the datasheet rather than assuming: a 4,000 W continuous inverter with an 8,000 W surge rating covers a 4,100 W surge need comfortably, but a budget inverter with a 1.5 times surge rating would not. If the tool shows no inverter size, it is because no peak load was entered and no loads were ticked: add up the watts of everything that runs at the same time and enter it. For the small end of the same question, our Power Bank Capacity Planner covers portable power, and our Cordless Drill Battery Runtime Estimator covers tool batteries.
Features
Two ways to enter daily use. Enter kilowatt-hours directly when you know them, or build from the 22-load estimator when you do not. The estimator covers the loads a farmhouse actually runs, including two well pump sizes, a sump pump, a chest freezer, and a furnace fan, with LED lighting counted by the bulb. When loads are ticked they govern the result, and the tool says so in the guidance.
Full system sizing in one pass. Array watts, panel count, battery amp-hours and kilowatt-hours, and inverter continuous and surge watts come out of one calculation, with each figure feeding the next. The panel count is worked out from the rounded-up array figure, so the installed array never falls short of the calculated size, and the battery bank is checked so the printed usable energy always covers the full autonomy period.
Motor starting surge. The estimator tracks starting watts for the five motor loads and adds the largest single starting surge to the peak load for the inverter surge rating. The result names the motor, its starting watts, and the surge rating the inverter needs, so a well pump start does not trip the system on the first day.
Warnings that catch the expensive mistakes. Low sun hours, summer sun hours entered by mistake, a 12 V system carrying a farmhouse load, a 24 V system carrying a large home, an array above 10 kW, and a large lead-acid bank all earn a warning with the reason and the fix. The warnings fire on the numbers you see, so a warning never contradicts a figure on the page.
Every figure checkable by hand. The steps print the full working: daily use, array size with the raw figure before rounding, panel count with the division, battery bank with the raw amp-hours before rounding, usable energy with the multiplication, inverter with the headroom, and surge with the extra starting watts. Worked examples in this page use the same numbers the tool produces, so you can verify the tool against the page and the page against your own arithmetic.
Current 2026 figures. Panel wattages follow EnergySage Marketplace data for the first half of 2026, when 97% of quoted home panels were 400 to 460 W. Sun-hour ranges come from state data based on the National Solar Radiation Database. Appliance wattages come from the Department of Energy Energy Saver list and the Champion wattage chart, re-checked on 22 November 2026. Household use follows the Energy Information Administration 2022 figure of 10,791 kWh a year. The page carries a last-reviewed date and a six-month review cycle, so stale figures get caught.
Use cases
A farmhouse going off-grid. The most common case: a rural home with a well, a freezer, and a furnace, leaving the grid or building where the grid does not reach. Start with the load estimator, tick everything, and set honest hours. The well pump and the freezer usually dominate the peak, and the water heater usually dominates the energy: moving water heating to propane often halves the system. Size on the darkest month, pick 48 V and lithium unless budget forces lead-acid, and keep a generator for the long gray spells. Our Farm Machinery Cost Calculator and Livestock Housing Space Calculator cover the working side of the same farm.
A cabin or weekend place. Small daily use, one or two days of autonomy, and a 12 V or 24 V system. The cabin example on this page, 2 kWh a day on 12 V lead-acid with 3 days of autonomy, needs a 750 W array and a 1,000 Ah bank. A weekend cabin used two days a week can size on the average over the week rather than the daily peak, because the battery recharges during the five empty days, but only if the array can refill the bank between visits: check the weekly energy balance, not just the daily one.
A barn, workshop, or outbuilding. Outbuildings have spiky loads: a welder, a compressor, a table saw, or a stock tank heater that runs all winter. Size the inverter on the largest single tool plus everything else running at the same time, and size the array on the winter daily total, when the days are short and the heater runs longest. A separate small system for the barn is often cheaper than upsizing the house system to cover it, because the barn loads are intermittent and the cable run from the house is long.
Backup power for a grid-connected farmhouse. The same math sizes a backup system: pick the loads that must stay on in an outage, fridge, freezer, well pump, furnace fan, lights, router, and size the battery for the longest outage you plan for. One day of autonomy with a generator for recharge is the usual shape. The array can be smaller than a full off-grid system, because the grid does the daily charging and the panels only need to stretch the battery through the outage. Our Home Generator Size Calculator sizes the generator that pairs with it.
A chicken coop, greenhouse, or smallholding setup. Small loads, long hours: heat lamps, fans, water heaters for stock, and lighting on timers. The estimator covers fans and lighting, and the daily total is usually small enough for a 12 V system. Watch the winter loads: a stock tank heater at 1,500 W running 8 hours a day uses 12 kWh, more than a whole cabin, and it runs in the darkest months. Our Chicken Coop Size Calculator and Tractor Horsepower Calculator cover the livestock and machinery side.
Checking a quote from an installer. Enter your daily use and sun hours, and compare the tool result with the installer's proposal. If the installer array is much smaller than the tool array, ask which sun hours they used: a yearly average instead of a winter month is the most common reason for an undersized quote. If the battery is much smaller, ask which depth of discharge they assumed: a lead-acid bank quoted at 80% usable will not last. The tool is a planning estimate, not a design, but it is an honest second opinion, and the steps show every number the opinion rests on.
Cutting the bill before sizing the system. The cheapest watt is the one you never use. Swapping incandescent bulbs for LEDs cuts lighting energy by about 80%: ten 60 W bulbs running 5 hours a day use 3,000 Wh, while ten 12 W LEDs use 600 Wh. A Room Lighting Calculator and a Ceiling Fan Size Calculator help with the lighting and cooling side, and a Mini-Split BTU Sizer sizes efficient heating and cooling. A Dehumidifier Size Calculator covers damp basements and barns. Every kilowatt-hour cut from daily use cuts the array, the battery, and the inverter together.
Sources
Every dated figure on this page was re-verified from the publisher on 22 November 2026. Where sources disagree, the resolution is recorded here.
- Solar array and battery formulas. Array watts equals daily watt-hours divided by peak sun hours times 1.3 for losses; battery amp-hours equals daily watt-hours times days of autonomy divided by depth of discharge times system voltage; inverter watts equals peak load times 1.25. The same three formulas appear in published off-grid sizing guides, including the ZZPine off-grid sizing calculator and the MySolarFY 2026 sizing guide, both read 22 November 2026. The 1.3 loss factor matches the long-standing PVWatts derate of 0.77, since 1 divided by 0.77 is 1.30.
- Peak sun hours. State averages from NREL PVWatts v8 and National Solar Radiation Database data, as published by The Green Watt (US average 4.98, Arizona 6.54, New Mexico 6.42, Nevada 6.41, California 6.08, Hawaii 5.82, Colorado 5.66, Washington 3.95, Alaska 3.17) and Unbound Solar (Arizona 6.5, California 5.6, Texas 5.3, New York 4.0, Washington 3.8, Alaska 3.0, national average about 5.0), both read 22 November 2026. The two sources differ by up to 0.5 hours for some states because they use different representative cities and tilt assumptions, so this page publishes regional ranges rather than single state figures. Exact sun hours for an address come from PVWatts, the free calculator from the National Laboratory of the Rockies, the lab formerly called NREL. The old address, pvwatts.nrel.gov, no longer answers: the lab was renamed on 1 December 2025 and the calculator moved to pvwatts.nlr.gov, verified live 22 November 2026.
- Appliance wattages. US Department of Energy Energy Saver list of typical appliance wattages, as reproduced by Virginia Cooperative Extension publication BSE-301 and by Penn State EGEE 102, both read 22 November 2026. The Department of Energy page itself has moved and the old address returns a 404, so the extension reproduction is the cited copy. Champion Power Equipment generator wattage chart ranges, as reproduced by Watt and Warden, read 22 November 2026. Router 10 to 20 W and phone charger 10 W cross-checked against published appliance charts the same day.
- Battery depth of discharge and efficiency. Lead-acid 50% usable, lithium (LiFePO4) 80% usable, per the standard sizing guides read 22 November 2026, including SolarCalcKit, VoltFlow, Wattsizing, and WeatherPV. Some guides use 85% for LiFePO4; this tool uses the conservative 80%. Round-trip efficiency about 95% for lithium, 75 to 85% for lead-acid, and cycle life 500 to 1,500 for lead-acid against 3,000 to 7,000 for lithium, per VoltFlow and WeatherPV. Cold-charging limit below 0 degrees C for lithium, and 20 to 40% cold capacity loss for lead-acid, per WeatherPV and the 6th Star sizing guide.
- Household electricity use. US Energy Information Administration: the average residential customer used 10,791 kWh in 2022, 899 kWh a month, about 29.6 kWh a day; Louisiana highest at 14,774 kWh, Hawaii lowest at 6,178 kWh. Verified from EIA reporting read 22 November 2026. The 2024 average was 10,359 kWh; the 2022 figure is used because it is the figure the EIA FAQ still publishes.
- Panel wattage. EnergySage, updated 20 October 2026: about 97% of home solar panels quoted in the first half of 2026 produce between 400 and 460 watts, with the largest share, 47%, quoted between 430 and 440 watts. Cross-checked against 2026 manufacturer datasheets via Helios Energy Global, which puts current residential panels at 410 to 475 watts.
- System voltage guidance. Systems above roughly 2 to 3 kWh a day are usually built at 24 V or 48 V, per the 6th Star sizing guide; 24 V suits 2,000 to 3,000 W inverters, per Wattsizing. The tool warning thresholds, 12 V above 3 kWh a day and 24 V above 10 kWh a day, are this tool's own rules, set from that guidance.
- Firewood and heating context. Homes that heat with wood cut the electric load sharply. Our Firewood BTU Calculator sizes the wood side of that choice.
Last reviewed: 22 November 2026. Next review due: 22 May 2027. At review, re-check the panel wattage range against EnergySage Marketplace data, re-check the sun-hour state figures against PVWatts, re-check the EIA household use figure for a newer year, and confirm the PVWatts address is still pvwatts.nlr.gov.
Frequently asked questions
How many solar panels do I need for an off-grid farmhouse?
Divide your daily watt-hours by your peak sun hours, multiply by 1.3 for system losses, and divide by your panel wattage, rounding up. A farmhouse using 5,000 Wh a day with 4.5 peak sun hours needs 5,000 divided by 4.5 times 1.3, which is 1,444.4 W, rounded up to 1,450 W, or 4 panels of 400 W, giving 1,600 W installed. The same home in Arizona at 6.5 peak sun hours needs 1,000 W, or 3 panels of 400 W, and in Washington at 3.95 peak sun hours it needs 1,650 W, or 5 panels. Daily use moves the answer most: halving your use halves the panel count, which is why cutting the big electric loads comes before buying panels.
What are peak sun hours, and where do I find mine?
A peak sun hour is one hour of sunlight at an average intensity of 1,000 watts per square meter, the same reference intensity used to rate solar panels. A day with 5 peak sun hours delivers 5 kWh of solar energy per square meter, even though the sun may be up for 12 hours or more. The US averages about 5 peak sun hours a day, ranging from 6.54 in Arizona to 3.17 in Alaska. Your exact figure comes from PVWatts, the free calculator from the National Laboratory of the Rockies at pvwatts.nlr.gov: enter your address and it gives month-by-month sun hours from the National Solar Radiation Database. For off-grid sizing, use your darkest month, not the yearly average, because a system that only balances in June goes dark in December.
How big a battery bank do I need for 2 days of autonomy?
Multiply your daily watt-hours by the days of autonomy, then divide by depth of discharge times system voltage. A farmhouse using 5,000 Wh a day with 2 days of autonomy on a 48 V lithium bank at 80% depth of discharge needs 5,000 times 2 divided by 0.8 times 48, which is 260.4 Ah, rounded up to 261 Ah, a 12.53 kWh bank with 10.02 kWh usable. The same home on lead-acid at 50% needs 5,000 times 2 divided by 0.5 times 48, which is 416.7 Ah, rounded up to 417 Ah, a 20.02 kWh bank with 10.01 kWh usable. Every extra day of autonomy adds the same again to the bank, so a 4-day bank is double a 2-day bank, and a generator for recharging is usually cheaper than the extra days.
Is 12 V, 24 V, or 48 V best for an off-grid home?
48 V suits most farmhouse systems, 24 V suits medium systems, and 12 V suits small systems only. The reason is current: a 3,000 W inverter draws 250 amps from a 12 V bank, 125 amps at 24 V, and 62.5 amps at 48 V, and thick cables for high currents are expensive and lose more energy as heat. Systems above roughly 2 to 3 kWh a day are usually built at 24 V or 48 V. This tool warns when a 12 V system is asked to carry more than 3 kWh a day, and when a 24 V system is asked to carry more than 10 kWh a day. 12 V still makes sense for a cabin, a workshop, or a barn with a small array, where the parts are common and cheap and 12 V lights and appliances run directly off the bank.
Should I choose lead-acid or lithium batteries?
Lithium iron phosphate is the better choice for most new off-grid systems, and lead-acid is the better choice when the budget is tight and the bank stays small. Lithium gives 80% usable capacity against 50% for lead-acid, so a lithium bank needs only 62.5% of the rated capacity for the same usable energy, and it returns about 95% of the energy put into it against 75 to 85% for lead-acid. Lithium lasts 3,000 to 7,000 cycles against 500 to 1,500 for lead-acid, weighs about a fifth as much for the same usable energy, and needs no watering. Lead-acid costs less up front and tolerates charging in the cold, where lithium must not be charged below 0 degrees C (32 degrees F) unless the battery has built-in heating. For a large bank or three or more days of autonomy, the size and weight gap usually settles it for lithium.
What size inverter do I need off-grid?
Multiply your peak load, the watts of everything running at the same time, by 1.25 for headroom, and round up to the nearest 100 W. A 3,000 W peak load needs 3,750 W, rounded up to a 3,800 W inverter, and an 8,000 W peak load needs 10,000 W exactly. Then check the surge rating against your largest motor start: a 1/2 HP well pump draws 875 W running and 1,750 W to start, an extra 875 W, so a 3,151 W peak load with that pump needs a surge rating of 3,151 plus 875, which is 4,026 W, rounded up to 4,100 W. Only the largest single surge is added, because motors start one at a time. If two big motors can start together, add both surges by hand and check the inverter surge rating against that total.
Should I size on the yearly average sun hours or the winter figure?
Size on the winter figure, always. Off-grid systems fail in winter, not in summer: December in Oregon delivers about 2 peak sun hours a day against more than 6 in July, and a system sized on the yearly average of about 4 runs short all winter. Enter the peak sun hours of your darkest month, from the PVWatts monthly table for your address, and let the summer surplus go unused. The same logic applies to the battery: winter is when the gray spells are longest, so the days of autonomy you pick should cover a winter storm run, not a summer cloudy afternoon. If the winter-sized array looks large, that is the honest size: an array that balances only in June is not an off-grid system.
Can I run an electric water heater or dryer off-grid?
You can, but both are expensive to run on solar, and most off-grid homes move them to gas, propane, or a heat pump instead. An electric water heater at 5,000 W running 3 hours a day uses 15,000 Wh, more than the rest of a careful farmhouse put together, and on its own it needs an array of 15,000 divided by 4.5 times 1.3, which is 4,333.3 W, rounded up to 4,340 W, plus a 2-day lithium bank at 48 V of 15,000 times 2 divided by 38.4, which is 781.25 Ah, rounded up to 782 Ah. An electric dryer at 3,400 W for an hour uses 3,400 Wh a load. A heat pump water heater uses about a third of the electricity of a resistance heater for the same hot water, and a clothesline uses none at all, which is why the first step in off-grid sizing is usually cutting the load, not growing the array.
Page history
- — Published (saleem891@gmail.com)